133 research outputs found
Atrial Fibrillation Ablation: A Single Center Comparison Between Remote Magnetic Navigation, Cryoballoon and Conventional Manual Pulmonary Vein Isolation
Contains fulltext :
88398.pdf (publisher's version ) (Open Access)BACKGROUND: The aim of the study was to compare in our center the effect of different ablation techniques on intermediate term freedom from atrial fibrillation (AF) or atrial tachycardia (AT) in patients affected by refractory AF. METHODS AND RESULTS: We retrospectively selected 94 patients who underwent AF ablation in our electrophysiological laboratory from June 2007 to December 2009. 29 patients underwent manual circumferential pulmonary vein isolation (mCPVI), 35 underwent remote magnetic navigation assisted CPVI (rmtCPVI) and 30 cryoballoon CPVI (cCPVI). Antiarrhythmic drugs were systematically stopped 2 months after the procedure (end of the "blanking period"). At a mean follow-up of 12,64 +/- 6,41 months (range 2-31), the success rate for mCPVI group was 65.5% (19 patients), 66.7 % (20 patients) for the rmtCPVI group and 65.7 % (23 patients) for the cCPVI group (p = 0.625). Procedural and fluoroscopy times were significantly reduced in the cCPVI group (both p < 0.001). Univariate Cox regression showed that no clinical variables were independently associated with recurrence. CONCLUSIONS: In our center's experience cCPVI and rmtCPVI have been demonstrated to be as effective as mCPVI. cCPVI seemed to be associated with lower procedural and fluoroscopy times
Compatibility assessment of a temperature-controlled radiofrequency catheter with a novel electroanatomical mapping system
BackgroundThe novel DiamondTemp ablation system (DTA) and EnSiteX mapping System (EAM) are both CE-Marked and FDA approved medical devices. The DTA has been validated by its manufacturer only in combination with previous version of EnSite System—EnSite Precision. The aim of this study was to evaluate compatibility of DTA with EnSite X with a previously developed protocol.MethodsThree configurations were tested: 3.1. Medtronic Generator connection Box (GCB) and AmpereConnect cable; 3.2. the Medtronic GCB-E and electrogram out cable from GCB to EAM; 3.3. Direct connection of DTA to EAM using intracardiac out cable with no GCB.ResultsThe previously developed universal method for compatibility assessment of ablation catheters and navigation systems was used with success for assessing DTA and EnSite X EAM compatibility, with reproducible results. Accuracy of DTA visualization with different setups was evaluated with a phantom model measuring distances between DTA and reference points. DTA is compatible with EnSiteX EAM with a safety and reliability profile guaranteed, if within the described specifications. In particular, careful setup is mandatory to achieve good clinical outcomes as only setup 3.2 is viable for both NavX and Voxel Mode and demonstrated satisfactory results and accuracy. Setup 3.3 showed a significant shift immediately after catheter insertion. Catheter position was away from baseline points and the dislocation increased during the radiofrequency delivery.ConclusionsPreviously developed method for compatibility assessment of ablation catheters and navigation systems has been used for a new EAM. DTA is compatible with EnSiteX EAM with proper configuration
Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in Septuagenarians: a Prospective Study
Contains fulltext :
87905.pdf (publisher's version ) (Open Access)AIMS: To evaluate the effects of pulmonary vein isolation (PVI) in terms of feasibility, safety and success rate on a midterm follow-up period in septuagenarians undergoing ablation with the Arctic Front Cryoballoon for atrial fibrillation (AF). METHODS AND RESULTS: We prospectively enrolled 21 patients aged 70 years or older (14 male; age 73 +/- 2.5 years) elected to circumferential PVI with the 28mm cryoballoon for symptomatic drug resistant paroxysmal AF. A total number of 82 pulmonary veins (PV) were evidenced. Successful isolation could be obtained in all 82 (100%) PV ostia at the end of procedure. No major complication occurred during procedure. At a mean follow-up of 11.5 +/- 4.7 months following ablation, 62% of patients did not present recurrence of atrial arrhythmias. CONCLUSION: Cryoballoon ablation may be feasible and safe in older patients. Moreover a large proportion of the latter did not present AF recurrence during follow-up
Cryoballoon ablation for atrial fibrillation: Effects on neuromodulation
Pulmonary vein isolation (PVI) represents the mainstay of atrial fibrillation (AF) ablation, and PVI with cryoballoon catheter (CB) ablation (CB-A) has proven to be as effective and safe as radiofrequency ablation (RF-A). Although AF is initiated by triggers arising from the pulmonary veins (PV) and non-PV foci, the intrinsic cardiac nervous system (ICNS) plays a significant role in the induction and maintenance of AF. The ICNS is an epicardial neural system composed of ganglionated plexi (GPs) and a complex network of interconnecting neurons. In the left atrium, the major GPs are located in proximity to the PV-left atrial junction. Vagal reactions have been described as markers of autonomic modulation during PVI with both RF-A and CB-A. The occurrence of neuromodulation during PVI with CB-A may be explained by both the anatomical relationship between the GPs and the PVs and the characteristics of the CB. Due to the CB/PV size mismatch, the CB creates a wide ablation area that extends from the PV ostium toward the antrum, possibly including the GPs. Although targeted GPs ablation, as a supplemental strategy to PVI, has been associated with a better AF outcome in patients undergoing RF-A, the additional clinical benefit of neuromodulation during PVI with CB-A remains a matter of debate. In this review, we provide an overview of the anatomy of the ICNS, the relationship between the ICNS and AF pathophysiology, and the current evidence on the clinical relevance of neuromodulation during PVI with CB-A
Abnormally high risk of stroke in Brugada syndrome
BACKGROUND
The present study sought to evaluate the incidence of cerebrovascular events in a large cohort of patients with Brugada syndrome (BrS) analysing possible predictors, clinical characteristics and prognosis of cardioembolic events secondary to atrial fibrillation.
METHODS
A total of 671 consecutive patients (age 42.1 ± 17.0 years; men 63%) with a diagnosis of BrS were retrospectively analysed over a mean follow-up period of 10.8 ± 5.5 years. The diagnosis of ischemic stroke was made according to the AHA/ASA guidelines using computed tomography (CT) and angio-CT in the emergency department.
RESULTS
Among 671 patients with BrS, 79 (11.8%) had atrial fibrillation. The incidence of cardioembolic stroke in patients with BrS and atrial fibrillation was 13.9% (11 events). These patients had a low CHA2DS2Vasc score (82%, 0 and 1). Patients with transient ischemic attack/stroke were more frequently asymptomatic (91 vs. 25%; P < 0.0001) and older (59.4 ± 11.2 vs. 43.9 ± 16.7; P = 0.004) as compared with those without cerebrovascular events.
CONCLUSION
The incidence of cardioembolic stroke in patients with BrS and atrial fibrillation was unexpectedly high. The cerebrovascular accidents were often the presenting clinical manifestation and were significantly associated with asymptomatic atrial fibrillation and older age. CHADS2 and CHA2DS2Vasc scores did not predict the unexpectedly high risk of thromboembolic events in this group of patients. The use of more invasive diagnostic tools might be useful in order to increase the rate of atrial fibrillation detection
Drug-Induced Brugada Syndrome in Children Clinical Features, Device-Based Management, and Long-Term Follow-Up
ObjectivesThe goal of this study was to investigate the clinical features, management, and long-term follow-up of children with drug-induced Brugada syndrome (BS).BackgroundPatients with BS <12 years of age with a spontaneous type I electrocardiogram have a higher risk of arrhythmic events. Data on drug-induced BS in patients <12 years of age are lacking.MethodsAmong 505 patients with ajmaline-induced BS, subjects ≤12 years of age at the time of diagnosis were considered as children and eligible for this study.ResultsForty children (60% male; age 8 ± 2.8 years) were included. Twenty-four children (60%) had a family history of sudden death. Two (5%) had a previous episode of aborted sudden death, and 8 (20%) had syncope. Children experienced more frequent episodes of sinus node dysfunction (SND) compared with older subjects (7.5% vs. 1.5%; p = 0.04) and had a comparable incidence of atrial tachyarrhythmias. Children more frequently experienced episodes of ajmaline-induced sustained ventricular arrhythmias (VAs) compared with older patients (10.0% vs. 1.3%; p = 0.005). Twelve children (30%) received an implantable cardioverter-defibrillator (ICD). After a mean follow-up time of 83 ± 51 months, none of the children died suddenly. Spontaneous sustained VAs were documented in 1 child (2%). Among children with ICD, 1 (8%) experienced an appropriate shock, 4 (33%) had inappropriate ICD shocks, and 4 (33%) experienced device-related complications.ConclusionsDrug-induced BS is associated with atrial arrhythmias and SND. Children are at higher risk of ajmaline-induced VAs. The rate of device-related complications, leading to lead replacement or inappropriate shocks, is considerable and even higher than with appropriate interventions. Based on these findings, the optimal management of BS in childhood should remain individualized, taking into consideration the patient's clinical history and family's wishes
- …