89 research outputs found

    Droplet breakup driven by shear thinning solutions in a microfluidic T-Junction

    Get PDF
    Droplet-based microfluidics turned out to be an efficient and adjustable platform for digital analysis, encapsulation of cells, drug formulation, and polymerase chain reaction. Typically, for most biomedical applications, the handling of complex, non-Newtonian fluids is involved, e.g. synovial and salivary fluids, collagen, and gel scaffolds. In this study we investigate the problem of droplet formation occurring in a microfluidic T-shaped junction, when the continuous phase is made of shear thinning liquids. At first, we review in detail the breakup process providing extensive, side-by-side comparisons between Newtonian and non-Newtonian liquids over unexplored ranges of flow conditions and viscous responses. The non-Newtonian liquid carrying the droplets is made of Xanthan solutions, a stiff rod-like polysaccharide displaying a marked shear thinning rheology. By defining an effective Capillary number, a simple yet effective methodology is used to account for the shear-dependent viscous response occurring at the breakup. The droplet size can be predicted over a wide range of flow conditions simply by knowing the rheology of the bulk continuous phase. Experimental results are complemented with numerical simulations of purely shear thinning fluids using Lattice Boltzmann models. The good agreement between the experimental and numerical data confirm the validity of the proposed rescaling with the effective Capillary number.Comment: Manuscript: 11 pages 5 figures, 65 References. Textual Supplemental Material: 6 pages 3 figure. Video Supplemental Materials: 2 movie

    Reti di code

    Get PDF
    openFULL TEX

    How Do Metal Ion Levels Change over Time in Hip Resurfacing Patients? A Cohort Study

    Get PDF
    Metal-on-metal hip resurfacing (MOM-HR) is offered as an alternative to traditional hip arthroplasty for young, active adults with advanced osteoarthritis. Nevertheless, concerns remain regarding wear and corrosion of the bearing surfaces and the resulting increase in metal ion levels. We evaluated three cohorts of patients with Birmingham hip resurfacing (BHR) at an average follow-up of 2, 5, and 9 years. We asked whether there would be differences in ion levels between the cohorts and inside the gender. Nineteen patients were prospectively analyzed. The correlation with clinical-radiographic data was also performed. Chromium, cobalt, nickel, and molybdenum concentrations were measured by atomic absorption spectrophotometry. Chromium and cobalt levels demonstrated a tendency to decrease over time. Such tendency was present only in females. An inverse correlation between chromium, implant size, and Harris hip score was present at short term; it disappeared over time together with the decreased ion levels. The prospective analysis showed that, although metal ion levels remained fairly constant within each patient, there was a relatively large variation between subjects, so mean data in this scenario must be interpreted with caution. The chronic high exposure should be carefully considered during implant selection, particularly in young subjects, and a stricter monitoring is mandatory

    Development and In-House Validation of an Enzyme-Linked Immunosorbent Assay and a Lateral Flow Immunoassay for the Dosage of Tenofovir in Human Saliva

    Get PDF
    Highly active antiretroviral therapy (HAART) includes very potent drugs that are often characterized by high toxicity. Tenofovir (TFV) is a widely used drug prescribed mainly for pre-exposure prophylaxis (PreP) and the treatment of human immunodeficiency virus (HIV). The therapeutic range of TFV is narrow, and adverse effects occur with both underdose and overdose. The main factor contributing to therapeutic failure is the improper management of TFV, which may be caused by low compliance or patient variability. An important tool to prevent inappropriate administration is therapeutic drug monitoring (TDM) of compliance-relevant concentrations (ARCs) of TFV. TDM is performed routinely using time-consuming and expensive chromatographic methods coupled with mass spectrometry. Immunoassays, such as enzyme-linked immunosorbent assays (ELISAs) and lateral flow immunoassays (LFIAs), are based on antibody–antigen specific recognition and represent key tools for real-time quantitative and qualitative screening for point-of-care testing (POCT). Since saliva is a non-invasive and non-infectious biological sample, it is well-suited for TDM. However, saliva is expected to have a very low ARC for TFV, so tests with high sensitivity are required. Here, we have developed and validated a highly sensitive ELISA (IC50 1.2 ng/mL, dynamic range 0.4–10 ng/mL) that allows the quantification of TFV in saliva at ARCs and an extremely sensitive LFIA (visual LOD 0.5 ng/mL) that is able to distinguish between optimal and suboptimal ARCs of TFV in untreated saliva

    Bacterial ligands as flexible and sensitive detectors in rapid tests for antibodies to SARS-CoV-2

    Get PDF
    Lateral flow immunoassay (LFIA) is widely employed as point-of-care tests (POCT) for the diagnosis of infectious diseases. The accuracy of LFIA largely depends on the quality of the immunoreagents used. Typical LFIAs to reveal the immune response to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) employ anti-human immunoglobulin (hIG) antibodies and recombinant viral antigens, which usually are unstable and poorly soluble. Broad selective bacterial proteins, such as Staphylococcal protein A (SpA) and Streptococcal protein G (SpG) can be considered alternatives to anti-hIG to increase versatility and sensitivity of serological LFIAs because of their high binding capacity, interspecies reactivity, and robustness. We developed two colorimetric LFA devices including SpA and SpG linked to gold nanoparticles (GNP) as detectors and explored the use of a specific, stable, and soluble immunodominant fraction of the nucleocapsid protein from SARS-CoV-2 as the capturing agent. The optimal amount of SpA-GNP and SpG-GNP conjugates and the protein-to-GNP ratios were defined through a full factorial experimental design to maximize the diagnostic sensitivity of the LFIAs. The new LFA devices were applied to analyze 105 human serum samples (69 positive and 36 negatives according to reference molecular diagnostic methods). The results showed higher sensitivity (89.9%, 95% CI 82.7-97.0) and selectivity (91.7%, 82.6-100) for the SpA-based compared to the SpG-based LFA. In addition, 18 serum samples from cats and dogs living with COVID-19 patients were analyzed and 14 showed detectable levels of anti-SARS-CoV-2 antibodies, thus illustrating the flexibility of the SpA- and SpG-based LFAs
    • …
    corecore