164 research outputs found
Comparison of image processing techniques for nonviable tissue quantification in late gadolinium enhancement cardiac magnetic resonance images
Purpose: The aim of this study was to compare the performance of quantitative methods, either semiautomated or automated, for left ventricular (LV) nonviable tissue analysis from cardiac magnetic resonance late gadolinium enhancement (CMR-LGE) images. Materials and Methods: The investigated segmentation techniques were: (i) n-standard deviations thresholding; (ii) full width at half maximum thresholding; (iii) Gaussian mixture model classification; and (iv) fuzzy c-means clustering. These algorithms were applied either in each short axis slice (single-slice approach) or globally considering the entire short-axis stack covering the LV (global approach). CMR-LGE images from 20 patients with ischemic cardiomyopathy were retrospectively selected, and results from each technique were assessed against manual tracing. Results: All methods provided comparable performance in terms of accuracy in scar detection, computation of local transmurality, and high correlation in scar mass compared with the manual technique. In general, no significant difference between single-slice and global approach was noted. The reproducibility of manual and investigated techniques was confirmed in all cases with slightly lower results for the nSD approach. Conclusions: Automated techniques resulted in accurate and reproducible evaluation of LV scars from CMR-LGE in ischemic patients with performance similar to the manual technique. Their application could minimize user interaction and computational time, even when compared with semiautomated approaches
Right ventricular endocardial segmentation in CMR images using a novel inter-modality statistical shape modelling approach
Statistical shape modelling (SSM) approaches have been proposed as a powerful tool to segment the left ventricle in cardiac magnetic resonance (CMR) images. Our aim was to extend this method to segment the RV cavity in CMR images and validate it compared to the conventional gold-standard (GS) manual tracing. A SSM of the RV was built using a database of 4347 intrinsically 3D surfaces, extracted from transthoracic 3D echo cardiographic (3DE) images of 219 retrospective patients. The SSM was then scaled and deformed on the base of some features extracted, with different strategies, from each short-axis plane until a stable condition was reached. The proposed approach, tested on 14 patients, resulted in a high correlation (r2=0.97) and narrow limits of agreement (± 17% error) when comparing the semiautomatic volumes to the GS, confirming the accuracy of this approach in segmenting the RV endocardium
Evaluation of different statistical shape models for segmentation of the left ventricular endocardium from magnetic resonance images
International audienceStatistical shape models (SSMs) represent a powerful tool used in patient-specific modeling to segment medical images because they incorporate a-priori knowledge that guide the model during deformation. Our aim was to evaluate segmentation accuracy in terms of left ventricular (LV) volumes obtained using four different SSMs versus manual gold standard tracing on cardiac magnetic resonance (CMR) images. A database of 3D echocardiographic (3DE) LV surfaces obtained in 435 patients was used to generate four different SSMs, based on cardiac phase selection. Each model was scaled and deformed to detect LV endocardial contours in the enddiastolic (ED) and end-systolic (ES) frames of a CMR short-axis (SAX) stack for 15 patients with normal LV function. Linear correlation and Bland–Altman analyses versus gold-standard showed in all cases high correlation (r²>0.95), non-significant biases and narrow limits of agreement
Light-induced dipole moment modulation in diarylethenes: a fundamental study
The dipole moment of photochromic diarylethenes is determined in solution for both the coloured and uncoloured forms by measuring the capacitance of a capacitor filled with a photochromic solution as a dielectric material. Diarylethenes with different substituents are investigated and the modulation of the dipole moment is related to their chemical structures. We determine a modulation of the dipole moment up to 4 Debye. We discuss the model used to obtain the dipole moment from the capacitance measurements and we compare the experimental results with the outcomes from DFT calculations. The results highlight the importance of conformational effects in the description of the dipole moment of diarylethenes
Indoor air pollution impacts cardiovascular autonomic control during sleep and the inflammatory profile
The present study explores the modifications of cardiovascular autonomic control (CAC) during wake and sleep time and the systemic inflammatory profile associated with exposure to indoor air pollution (IAP) in a cohort of healthy subjects. Twenty healthy volunteers were enrolled. Indoor levels of fine particulate matter (PM2.5), nitrogen dioxide (NO2) and volatile organic compounds (VOCs) were monitored using a portable detector for 7 days. Together, a 7-day monitoring was performed through a wireless patch that continuously recorded electrocardiogram, respiratory activity and actigraphy. Indexes of CAC during wake and sleep time were derived from the biosignals: heart rate and low-frequency to high-frequency ratio (LF/HF), index of sympathovagal balance with higher values corresponding to a predominance of the sympathetic branch. Cyclic variation of heart rate index (CVHRI events/hour) during sleep, a proxy for the evaluation of sleep apnea, was assessed for each night. After the monitoring, blood samples were collected to assess the inflammatory profile. Regression and correlation analyses were performed. A positive association between VOC exposure and the CVHRI (Δ% = +0.2% for 1 μg/m3 VOCs, p = 0.008) was found. The CVHRI was also positively associated with LF/HF during sleep, thus higher CVHRI values corresponded to a shift of the sympathovagal balance towards a sympathetic predominance (r = 0.52; p = 0.018). NO2 exposure was positively associated with both the pro-inflammatory biomarker TREM-1 and the anti-inflammatory biomarker IL-10 (Δ% = +1.2% and Δ% = +2.4%, for 1 μg/m3 NO2; p = 0.005 and p = 0.022, respectively). The study highlights a possible causal relationship between IAP exposure and higher risk of sleep apnea events, associated with impaired CAC during sleep, and a pro-inflammatory state counterbalanced by an increased anti-inflammatory response in healthy subjects. This process may be disrupted in vulnerable populations, leading to a harmful chronic pro-inflammatory profile. Thus, IAP may emerge as a critical and often neglected risk factor for the public health that can be addressed through targeted preventive interventions
3D right ventricular endocardium segmentation in cardiac magnetic resonance images by using a new inter-modality statistical shape modelling method
Objective
Statistical shape modelling (SSM) has established as a powerful method for segmenting the left ventricle in cardiac magnetic resonance (CMR) images However, applying them to segment the right ventricle (RV) is not straightforward because of the complex structure of this chamber. Our aim was to develop a new inter-modality SSM-based approach to detect the RV endocardium in CMR data.
Methods
Real-time transthoracic 3D echocardiographic (3DE) images of 219 retrospective patients were used to populate a large database containing 4347 3D RV surfaces and train a model. The initial position, orientation and scale of the model in the CMR stack were semi-automatically derived. The detection process consisted in iteratively deforming the model to match endocardial borders in each CMR plane until convergence was reached. Clinical values obtained with the presented SSM method were compared with gold-standard (GS) corresponding parameters.
Results
CMR images of 50 patients with different pathologies were used to test the proposed segmentation method. Average processing time was 2 min (including manual initialization) per patient. High correlations (r2 > 0.76) and not significant bias (Bland-Altman analysis) were observed when evaluating clinical parameters. Quantitative analysis showed high values of Dice coefficient (0.87 ± 0.03), acceptable Hausdorff distance (9.35 ± 1.51 mm) and small point-to-surface distance (1.91 ± 0.26 mm). Conclusion
A novel SSM-based approach to segment the RV endocardium in CMR scans by using a model trained on 3DE-derived RV endocardial surfaces, was proposed. This inter-modality technique proved to be rapid when segmenting the RV endocardium with an accurate anatomical delineation, in particular in apical and basal regions
A new 2D-based method for myocardial velocity strain and strain rate quantification in a normal adult and paediatric population: assessment of reference values
<p>Abstract</p> <p>Background</p> <p>Recent advances in technology have provided the opportunity for off-line analysis of digital video-clips of two-dimensional (2-D) echocardiographic images.</p> <p>Commercially available software that follows the motion of cardiac structures during cardiac cycle computes both regional and global velocity, strain, and strain rate (SR).</p> <p>The present study aims to evaluate the clinical applicability of the software based on the tracking algorithm feature (studied for cardiology purposes) and to derive the reference values for longitudinal and circumferential strain and SR of the left ventricle in a normal population of children and young adults.</p> <p>Methods</p> <p>45 healthy volunteers (30 adults: 19 male, 11 female, mean age 37 ± 6 years; 15 children: 8 male, 7 female, mean age 8 ± 2 years) underwent transthoracic echocardiographic examination; 2D cine-loops recordings of apical 4-four 4-chamber (4C) and 2-chamber (2C) views and short axis views were stored for off-line analysis.</p> <p>Computer analyses were performed using specific software relying on the algorithm of optical flow analysis, specifically designed to track the endocardial border, installed on a Windows™ based computer workstation. Inter and intra-observer variability was assessed.</p> <p>Results</p> <p>The feasibility of measurements obtained with tissue tracking system was higher in apical view (100% for systolic events; 64% for diastolic events) than in short axis view (70% for systolic events; 52% for diastolic events). Longitudinal systolic velocity decreased from base to apex in all subjects (5.22 ± 1.01 vs. 1.20 ± 0.88; p < 0.0001). Longitudinal strain and SR significantly increased from base to apex in all subjects (-12.95 ± 6.79 vs. -14.87 ± 6.78; p = 0.002; -0.72 ± 0.39 vs. -0.94 ± 0.48, p = 0.0001, respectively). Similarly, circumferential strain and SR increased from base to apex (-21.32 ± 5.15 vs. -27.02 ± 5.88, p = 0.002; -1.51 ± 0.37 vs. -1.95 ± 0.57, p = 0.003, respectively).</p> <p>Values of global systolic SR, both longitudinal and circumferential, were significantly higher in children than in adults (-1.3 ± 0.2, vs. -1.11 ± 0.2, p = 0.006; -1.9 ± 0.6 vs. -1.6 ± 0.5, p = 0.0265, respectively). No significant differences in longitudinal and circumferential systolic velocities were identified for any segment when comparing adults with children.</p> <p>Conclusion</p> <p>This 2D based tissue tracking system used for computation is reliable and applicable in adults and children particularly for systolic events. Measured with this technology, we have established reference values for myocardial velocity, Strain and SR for both young adults and children.</p
The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe
The preponderance of matter over antimatter in the early Universe, the
dynamics of the supernova bursts that produced the heavy elements necessary for
life and whether protons eventually decay --- these mysteries at the forefront
of particle physics and astrophysics are key to understanding the early
evolution of our Universe, its current state and its eventual fate. The
Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed
plan for a world-class experiment dedicated to addressing these questions. LBNE
is conceived around three central components: (1) a new, high-intensity
neutrino source generated from a megawatt-class proton accelerator at Fermi
National Accelerator Laboratory, (2) a near neutrino detector just downstream
of the source, and (3) a massive liquid argon time-projection chamber deployed
as a far detector deep underground at the Sanford Underground Research
Facility. This facility, located at the site of the former Homestake Mine in
Lead, South Dakota, is approximately 1,300 km from the neutrino source at
Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino
charge-parity symmetry violation and mass ordering effects. This ambitious yet
cost-effective design incorporates scalability and flexibility and can
accommodate a variety of upgrades and contributions. With its exceptional
combination of experimental configuration, technical capabilities, and
potential for transformative discoveries, LBNE promises to be a vital facility
for the field of particle physics worldwide, providing physicists from around
the globe with opportunities to collaborate in a twenty to thirty year program
of exciting science. In this document we provide a comprehensive overview of
LBNE's scientific objectives, its place in the landscape of neutrino physics
worldwide, the technologies it will incorporate and the capabilities it will
possess.Comment: Major update of previous version. This is the reference document for
LBNE science program and current status. Chapters 1, 3, and 9 provide a
comprehensive overview of LBNE's scientific objectives, its place in the
landscape of neutrino physics worldwide, the technologies it will incorporate
and the capabilities it will possess. 288 pages, 116 figure
- …