140 research outputs found

    Optical Coherence Tomography in Dentistry

    Get PDF

    Digital signal processor-based real-time optical Doppler tomography system

    Get PDF
    We present a real-time data-processing and display unit, based on a custom-designed digital signal processor (DSP) module for imaging tissue structure and Doppler blood flow. The DSP module is incorporated into a conventional optical coherence tomography system. We also demonstrate the flexibility of embedding advanced Doppler processing algorithms in the DSP module. Two advanced velocity estimation algorithms previously introduced by us are incorporated in this DSP module. Experiments on Intralipid flow demonstrate that a pulsatile flow of several hundred pulses per minute can be faithfully captured in M-scan mode by this DSP system. In vivo imaging of a rat's abdominal blood flow is also presented.Electrical and Computer Engineerin

    Documentation of Intraretinal Retinal Pigment Epithelium Migration via High-Speed Ultrahigh-Resolution Optical Coherence Tomography

    Get PDF
    Purpose To describe the features of intraretinal retinal pigment epithelium (RPE) migration documented on a prototype spectral-domain, high-speed, ultrahigh-resolution optical coherence tomography (OCT) device in a group of patients with early to intermediate dry age-related macular degeneration (AMD) and to correlate intraretinal RPE migration on OCT to RPE pigment clumping on fundus photographs. Design Retrospective, noncomparative, noninterventional case series. Participants Fifty-five eyes of 44 patients seen at the New England Eye Center between December 2007 and June 2008 with early to intermediate dry AMD. Methods Three-dimensional OCT scan sets from all patients were analyzed for the presence of intraretinal RPE migration, defined as small discreet hyperreflective and highly backscattering lesions within the neurosensory retina. Fundus photographs also were analyzed to determine the presence of RPE pigment clumping, defined as black, often spiculated, areas of pigment clumping within the macula. The en face OCT images were correlated with fundus photographs to demonstrate correspondence of intraretinal RPE migration on OCT and RPE clumping on fundus photography. Main Outcome Measures Drusen, dry AMD, intraretinal RPE migration, and RPE pigment clumping. Results On OCT scans, 54.5% of eyes (61.4% of patients) demonstrated intraretinal RPE migration. Of the fundus photographs, 56.4% demonstrated RPE pigment clumping. All eyes with intraretinal RPE migration on OCT had corresponding RPE pigment clumping on fundus photographs. The RPE pigment migrated most frequently into the outer nuclear layer (66.7% of eyes) and less frequently into more anterior retinal layers. Intraretinal RPE migration mainly occurred above areas of drusen (73.3% of eyes). Conclusions The appearance of intraretinal RPE migration on OCT is a common occurrence in early to intermediate dry AMD, occurring in 54.5% of eyes, or 61.4% of patients. The area of intraretinal RPE migration on OCT always correlated to areas of pigment clumping on fundus photography. Conversely, all but 1 eye with RPE pigment clumping on fundus photography also had areas of intraretinal RPE migration on OCT. The high incidence of intraretinal RPE migration observed above areas of drusen suggests that drusen may play physical and catalytic roles in facilitating intraretinal RPE migration in dry AMD patients.National Institutes of Health (U.S.) (Contract RO1-EY11289-23)National Institutes of Health (U.S.) (Contract R01-EY13178-07)National Institutes of Health (U.S.) (Contract R01-EY013516-07)United States. Air Force Office of Scientific Research (FA9550-07-1-0101)United States. Air Force Office of Scientific Research (FA9550-07-1-0014

    Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices

    Get PDF
    Purpose To report the frequency of optical coherence tomography (OCT) scan artifacts and to compare macular thickness measurements, interscan reproducibility, and interdevice agreeability across 3 spectral-domain (SD) OCT (also known as Fourier domain; Cirrus HD-OCT, RTVue-100, and Topcon 3D-OCT 1000) devices and 1 time-domain (TD) OCT (Stratus OCT) device. Design Prospective, noncomparative, noninterventional case series. Participants Fifty-two patients seen at the New England Eye Center, Tufts Medical Center Retina Service, between February and August 2008. Methods Two scans were performed for each of the SD OCT protocols: Cirrus macular cube 512×128 (software version 3.0; Carl Zeiss Meditec, Inc., Dublin, CA), RTVue (E)MM5 and MM6 (software version 3.5; Optovue, Inc., Fremont, CA), Topcon 3D Macular and Radial (software version 2.12; Topcon, Inc., Paramus, NJ), in addition to 1 TD OCT scan via Stratus macular thickness protocol (software version 4.0; Carl Zeiss Meditec, Inc.). Scans were inspected for 6 types of OCT scan artifacts and were analyzed. Interscan reproducibility and interdevice agreeability were assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots, respectively. Main Outcome Measures Optical coherence tomography image artifacts, macular thickness, reproducibility, and agreeability. Results Time-domain OCT scans contained a significantly higher percentage of clinically significant improper central foveal thickness (IFT) after manual correction (11-μm change or more) compared with SD OCT scans. Cirrus HD-OCT had a significantly lower percentage of clinically significant IFT (11.1%) compared with the other SD OCT devices (Topcon 3D, 20.4%; Topcon Radial, 29.6%; RTVue (E)MM5, 42.6%; RTVue MM6, 24.1%; P = 0.001). All 3 SD OCT devices had central foveal subfield thicknesses that were significantly more than that of TD OCT after manual correction (P<0.0001). All 3 SD OCT devices demonstrated a high degree of reproducibility in the central foveal region (ICCs, 0.92–0.97). Bland-Altman plots showed low agreeability between TD and SD OCT scans. Conclusions Out of all OCT devices analyzed, cirrus HD-OCT scans exhibited the lowest occurrence of any artifacts (68.5%), IFT (40.7%), and clinically significant IFT (11.1%), whereas Stratus OCT scans exhibited the highest occurrence of clinically significant IFT. Further work on improving segmentation algorithm to decrease artifacts is warranted.Research to Prevent Blindness, Inc. (United States) (Challenge Grant)National Institutes of Health (U.S.) (Grant R01-EY11289-23)National Institutes of Health (U.S.) (Grant R01-EY13178-07)National Institutes of Health (U.S.) (Grant P30-EY008098)United States. Air Force Office of Scientific Research (Grant FA9550-07-1-0101)United States. Air Force Office of Scientific Research (Grant FA9550-07-1-0014

    Hybrid positron detection and optical coherence tomography system: Design, calibration, and experimental validation with rabbit atherosclerotic models

    Get PDF
    We evaluate the performance of our novel hybrid optical coherence tomography (OCT) and scintillating probe, demonstrate simultaneous OCT imaging and scintillating detection, and validate the system using an atherosclerotic rabbit model. Preliminary data obtained from the rabbit model suggest that our prototype positron probe detects local uptake of fluorodeoxyglucose (FDG) labeled with F positron (beta) radionuclide emitter, and the high-uptake regions correlate with sites of injury and extensive atherosclerosis areas. Preliminary data also suggest that coregistered high-resolution OCT images provide imaging of detailed plaque microstructures, which cannot be resolved by positron detection.Electrical and Computer Engineerin

    Mechanism of intercalation and deintercalation of lithium ions in graphene nanosheets

    Get PDF
    Graphene nanosheets (GNSs) were synthesized by reducing exfoliated graphite oxides. Their structure, surface morphology and lithium storage mechanism were characterized and investigated systematically using X-ray diffraction, atomic force microscopy, scanning electron microscopy, charge-discharge tests, cyclic voltammetry and electrochemical impedance spectroscopy. It was found that the GNSs, which were obtained via chemical synthesis, were primarily less than 10 graphene layers. The GNS electrodes, which were fabricated from the reduced GNSs, exhibited an enhanced reversible lithium storage capacity and good cyclic stability when serving as anodes in lithium-ion batteries. Also, the first-cycle irreversible capacities of the system were relatively high, because of the formation of a solid electrolyte interphase film on the surface of the GNS electrode and the spontaneous stacking of GNSs during the first lithiation. The electrochemical impedance spectroscopy results suggest that the solid electrolyte interphase film on the GNS electrode during first lithiation were primarily formed at potentials between 0.95 and 0.7 V. Also, the symmetry factor of the charge transfer was measured to be 0.446.Fundamental Research Funds for the Central Universities[2010LKHX03, 2010QNB04, 2010QNB05]; China University of Mining Technology[ON090237

    Effects of obesity with reduced 25(OH)D levels on bone health in elderly Chinese people: a nationwide cross-sectional study

    Get PDF
    BackgroundObesity is often accompanied by lower 25(OH)D levels, whereas these two parameters exhibit opposite effects on bone health. It is uncertain what are the effects of lower 25(OH)D levels in obesity on bone health in elderly Chinese people.MethodsA nationally representative cross-sectional analysis of China Community-based Cohort of Osteoporosis (CCCO) was performed from 2016 to 2021, which consisted of 22,081 participants. Demographic data, disease history, Body mass index (BMI), bone mineral density (BMD), the levels of the biomarkers of vitamin D status and those of bone metabolism markers were measured for all participants (N = 22,081). The genes (rs12785878, rs10741657, rs4588, rs7041, rs2282679 and rs6013897) related to 25(OH)D transportation and metabolism were performed in a selected subgroup (N = 6008).ResultsObese subjects exhibited lower 25(OH)D levels (p &lt; 0.05) and higher BMD (p &lt; 0.001) compared with those of normal subjects following adjustment. The genotypes and allele frequency of rs12785878, rs10741657, rs6013897, rs2282679, rs4588 and rs7041 indicated no significant differences among three BMI groups following correction by the Bonferroni’s method (p &gt; 0.05). The levels of total 25(OH)D (ToVD) were significantly different among the GC1F, GC1S and GC2 haplotype groups (p &lt; 0.05). Correlation analysis indicated that ToVD levels were significantly correlated with parathyroid hormone levels, BMD, risk of osteoporosis (OP) and the concentration levels of other bone metabolism markers (p &lt; 0.05). Generalized varying coefficient models demonstrated that the increasing BMI, ToVD levels and their interactions were positively associated with BMD outcomes (p &lt; 0.001), whereas the reduced levels of ToVD and BMI increased the risk of OP, which was noted notably for the subjects with reduced ToVD levels (less than 20.69 ng/ml) combined with decreased BMI (less than 24.05 kg/m2).ConclusionThere was a non-linear interaction of BMI and 25(OH)D. And higher BMI accompanied by decreased 25(OH)D levels is associated with increased BMD and decreased incidence of OP, optimal ranges exist for BMI and 25(OH)D levels. The cutoff value of BMI at approximately 24.05 kg/m2 combined with an approximate value of 25(OH)D at 20.69 ng/ml are beneficial for Chinese elderly subjects

    Using a Relative Quantitative Proteomic Method to Identify Differentially Abundant Proteins in Brucella melitensis Biovar 3 and Brucella melitensis M5-90

    Get PDF
    Brucellosis, caused by Brucella spp., is one of the most widespread bacterial zoonoses worldwide. Vaccination is still considered the best way to control brucellosis. An investigation into the differential proteome expression patterns of wild and vaccine strains may help researchers and clinicians differentiate between the strains to diagnose and better understand the mechanism(s) underlying differences in virulence. In the present study, a mass spectrometry-based, label-free relative quantitative proteomics approach was used to investigate the proteins expressed by the wild strain, B. melitensis biovar 3 and compare it with those expressed by B. melitensis M5-90. The higher level of virulence for B. melitensis biovar 3 compared to B. melitensis M5-90 was validated in vitro and in vivo. A total of 2133 proteins, encompassing 68% of the theoretical proteome, were identified and quantified by proteomic analysis, resulting in broad coverage of the B. melitensis proteome. A total of 147 proteins were identified as differentially expressed (DE) between these two strains. In addition, 9 proteins and 30 proteins were identified as unique to B. melitensis M5-90 and B. melitensis biovar 3, respectively. Pathway analysis revealed that the majority of the DE proteins were involved in iron uptake, quorum sensing, pyrimidine metabolism, glycine betaine biosynthetic and metabolic processes, thiamine-containing compound metabolism and ABC transporters. The expression of BtpA and VjbR proteins (two well-known virulence factors) in B. melitensis biovar 3 was 8-fold and 2-fold higher than in B. melitensis M5-90. In summary, our results identified many unique proteins that could be selected as candidate markers for differentiating vaccinated animals from animals with wild-type infections. BtpA and VjbR proteins might be responsible for the residual virulence of B. melitensis M5-90, while ABC transporters and thiamine metabolism associated proteins may be newly identified Brucella virulence factors. All of the identified DE proteins provide valuable information for the development of vaccines and the discovery of novel therapeutic targets
    • …
    corecore