11,466 research outputs found

    Preventing Hepatitis B-induced Liver Cancer: Implications for Eliminating Health Disparities

    Full text link
    If the definition of eliminating of a health disparity were signified by the absence of any differences in incidence or mortality between a population’s experiences with a health problem, then the only health disparity that has ever been eliminated is smallpox because with zero cases of smallpox in the world, no health disparities exist because of smallpox. The eradication of smallpox is perhaps the only historical example where the elimination of a health disparity has been achieved. Principles and lessons learned, particularly through the intersection of science and policy that could be applied to the elimination of other health disparities both domestically and internationally are proposed

    Improving Temporal Accuracy of Human Metabolic Chambers for Dynamic Metabolic Studies

    Get PDF
    Metabolic chambers are powerful tools for assessing human energy expenditure, providing flexibility and comfort for the subjects in a near free-living environment. However, the flexibility offered by the large living room size creates challenges in the assessment of dynamic human metabolic signals—such as those generated during high-intensity interval training and short-term involuntary physical activities—with sufficient temporal accuracy. Therefore, this paper presents methods to improve the temporal accuracy of metabolic chambers. The proposed methods include 1) adopting a shortest possible step size, here one minute, to compute the finite derivative terms for the metabolic rate calculation, and 2) applying a robust noise reduction method—total variation denoising—to minimize the large noise generated by the short derivative term whilst preserving the transient edges of the dynamic metabolic signals. Validated against 24-hour gas infusion tests, the proposed method reconstructs dynamic metabolic signals with the best temporal accuracy among state-of-the-art approaches, achieving a root mean square error of 0.27 kcal/min (18.8 J/s), while maintaining a low cumulative error in 24-hour total energy expenditure of less than 45 kcal/day (188280 J/day). When applied to a human exercise session, the proposed methods also show the best performance in terms of recovering the dynamics of exercise energy expenditure. Overall, the proposed methods improve the temporal resolution of the chamber system, enabling metabolic studies involving dynamic signals such as short interval exercises to carry out the metabolic chambers

    Antitumour activity and plasma kinetics of bleomycin by continuous and intermittent administration.

    Get PDF
    We have studied the cytotoxicity of bleomycin (4--10 u/kg/day for 6 days) given by continuous i.p. infusion (using an osmotic minipump) compared to daily i.p. bolus administration, against P388 leukaemic spleen colony-forming-units(LCFU-S). Continuous i.p. bleomycin at 8 u/kg/day caused a 0.5 log greater reduction of LCFU-S than did an identical dose given by intermittent bolus administration. The infusion minipump provided constant bleomycin plasma levels of 0.62 +/- 0.03 mu/ml and a total plasma AUC (area under the plasma decay curve) of 89.0 mu.h/ml for 6 days at 8 u/kg/day. Intermittent bolus bleomycin at 8 u.kg/day had a terminal-phase plasma t1/2 of 15 min and a total 6-day plasma AUC of 90.8mu.h/ml. These pharmacokinetic data validate the osmotic minipump as a constant drug-delivery system, and suggest that the two administration schedules resulted in equal total bleomycin dosages. Although high peak bleomycin plasma levels (i.e. 32 mu/ml) were achieved with the intermittent bolus administration, continuous-infusion bleomycin's greater inhibition of LCFU-S was probably related to the drug's schedule-dependent cell-killing characteristics. The results of this study provide further rationale for the continuing use of infusion bleomycin schedules in cancer patients

    Novel components of the Toxoplasma inner membrane complex revealed by BioID.

    Get PDF
    UNLABELLED:The inner membrane complex (IMC) of Toxoplasma gondii is a peripheral membrane system that is composed of flattened alveolar sacs that underlie the plasma membrane, coupled to a supporting cytoskeletal network. The IMC plays important roles in parasite replication, motility, and host cell invasion. Despite these central roles in the biology of the parasite, the proteins that constitute the IMC are largely unknown. In this study, we have adapted a technique named proximity-dependent biotin identification (BioID) for use in T. gondii to identify novel components of the IMC. Using IMC proteins in both the alveoli and the cytoskeletal network as bait, we have uncovered a total of 19 new IMC proteins in both of these suborganellar compartments, two of which we functionally evaluate by gene knockout. Importantly, labeling of IMC proteins using this approach has revealed a group of proteins that localize to the sutures of the alveolar sacs that have been seen in their entirety in Toxoplasma species only by freeze fracture electron microscopy. Collectively, our study greatly expands the repertoire of known proteins in the IMC and experimentally validates BioID as a strategy for discovering novel constituents of specific cellular compartments of T. gondii. IMPORTANCE:The identification of binding partners is critical for determining protein function within cellular compartments. However, discovery of protein-protein interactions within membrane or cytoskeletal compartments is challenging, particularly for transient or unstable interactions that are often disrupted by experimental manipulation of these compartments. To circumvent these problems, we adapted an in vivo biotinylation technique called BioID for Toxoplasma species to identify binding partners and proximal proteins within native cellular environments. We used BioID to identify 19 novel proteins in the parasite IMC, an organelle consisting of fused membrane sacs and an underlying cytoskeleton, whose protein composition is largely unknown. We also demonstrate the power of BioID for targeted discovery of proteins within specific compartments, such as the IMC cytoskeleton. In addition, we uncovered a new group of proteins localizing to the alveolar sutures of the IMC. BioID promises to reveal new insights on protein constituents and interactions within cellular compartments of Toxoplasma

    Hypovitaminosis D and cervical disk herniation among adults undergoing spine surgery

    Get PDF
    Study Design Single-center, retrospective study. Objective Suboptimal concentrations of vitamin D have been linked to hip and knee osteoarthritis in large, population-based cohort studies. We sought to examine the association of vitamin D levels with intervertebral disk disease. Methods From January 2010 through May 2011, 91 consecutive, eligible adult spine surgery patients who had undergone cervical magnetic resonance imaging (MRI) and preoperative serum 25-hydroxyvitamin D (s25D) measurement were retrospectively included. MRI was read for C2–T1 disk herniation and degeneration (grades I to V). Logistic regressions were performed. Results Compared with the 384 disks of nondeficient patients, 162 disks of vitamin D-deficient (< 20 ng/mL) patients were more frequently herniated (40% versus 27%, p = 0.004); deficiency was not predictive of individual disk grade (unadjusted odds ratio [uOR] = 0.98, p = 0.817). On regression analysis, deficiency was associated with increased number of herniations per patient (uOR = 2.17, 95% confidence interval [CI] = 1.22 to 3.87, p = 0.009; adjusted odds ratio [aOR] = 2.12, 95% CI = 1.11 to 4.03, p = 0.023). When disks were analyzed individually, and levels (e.g., C5 to C6), additionally controlled for, deficiency correlated with greater likelihood of herniation per disk (uOR = 1.81, 95% CI = 1.22 to 2.66, p = 0.003; aOR = 2.06, 95% CI = 1.25 to 3.41, p = 0.005). Conclusion Among adults undergoing spine surgery at our institution, vitamin D deficiency was associated with cervical disk herniation. Considering the current epidemics of vitamin D insufficiency and neck pain, further investigation is warranted, as these data were retrospectively collected and subject to sampling bias
    corecore