22,730 research outputs found
Cross-Correlation-Function-Based Multipath Mitigation Method for Sine-BOC Signals
Global Navigation Satellite Systems (GNSS) positioning accuracy indoor and urban canyons environments are greatly affected by multipath due to distortions in its autocorrelation function. In this paper, a cross-correlation function between the received sine phased Binary Offset Carrier (sine-BOC) modulation signal and the local signal is studied firstly, and a new multipath mitigation method based on cross-correlation function for sine-BOC signal is proposed. This method is implemented to create a cross-correlation function by designing the modulated symbols of the local signal. The theoretical analysis and simulation results indicate that the proposed method exhibits better multipath mitigation performance compared with the traditional Double Delta Correlator (DDC) techniques, especially the medium/long delay multipath signals, and it is also convenient and flexible to implement by using only one correlator, which is the case of low-cost mass-market receivers
Deprojection technique for galaxy cluster considering point spread function
We present a new method for the analysis of Abell 1835 observed by
XMM-Newton. The method is a combination of the Direct Demodulation technique
and deprojection. We eliminate the effects of the point spread function (PSF)
with the Direct Demodulation technique. We then use a traditional depro-jection
technique to study the properties of Abell 1835. Compared to that of
deprojection method only, the central electron density derived from this method
increases by 30%, while the temperature profile is similar.Comment: accepted for publication in Sciences in China -- G, the Black Hole
special issu
Effect of Statistical Fluctuation in Monte Carlo Based Photon Beam Dose Calculation on Gamma Index Evaluation
The gamma-index test has been commonly adopted to quantify the degree of
agreement between a reference dose distribution and an evaluation dose
distribution. Monte Carlo (MC) simulation has been widely used for the
radiotherapy dose calculation for both clinical and research purposes. The goal
of this work is to investigate both theoretically and experimentally the impact
of the MC statistical fluctuation on the gamma-index test when the fluctuation
exists in the reference, the evaluation, or both dose distributions. To the
first order approximation, we theoretically demonstrated in a simplified model
that the statistical fluctuation tends to overestimate gamma-index values when
existing in the reference dose distribution and underestimate gamma-index
values when existing in the evaluation dose distribution given the original
gamma-index is relatively large for the statistical fluctuation. Our numerical
experiments using clinical photon radiation therapy cases have shown that 1)
when performing a gamma-index test between an MC reference dose and a non-MC
evaluation dose, the average gamma-index is overestimated and the passing rate
decreases with the increase of the noise level in the reference dose; 2) when
performing a gamma-index test between a non-MC reference dose and an MC
evaluation dose, the average gamma-index is underestimated when they are within
the clinically relevant range and the passing rate increases with the increase
of the noise level in the evaluation dose; 3) when performing a gamma-index
test between an MC reference dose and an MC evaluation dose, the passing rate
is overestimated due to the noise in the evaluation dose and underestimated due
to the noise in the reference dose. We conclude that the gamma-index test
should be used with caution when comparing dose distributions computed with
Monte Carlo simulation
Recommended from our members
Rapid, efficient, and economical synthesis of PET tracers in a droplet microreactor: application to O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET).
BackgroundConventional scale production of small batches of PET tracers (e.g. for preclinical imaging) is an inefficient use of resources. Using O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET), we demonstrate that simple microvolume radiosynthesis techniques can improve the efficiency of production by consuming tiny amounts of precursor, and maintaining high molar activity of the tracers even with low starting activity.ProceduresThe synthesis was carried out in microvolume droplets manipulated on a disposable patterned silicon "chip" affixed to a heater. A droplet of [18F]fluoride containing TBAHCO3 was first deposited onto a chip and dried at 100 °C. Subsequently, a droplet containing 60 nmol of precursor was added to the chip and the fluorination reaction was performed at 90 °C for 5 min. Removal of protecting groups was accomplished with a droplet of HCl heated at 90 °C for 3 min. Finally, the crude product was collected in a methanol-water mixture, purified via analytical-scale radio-HPLC and formulated in saline. As a demonstration, using [18F]FET produced on the chip, we prepared aliquots with different molar activities to explore the impact on preclinical PET imaging of tumor-bearing mice.ResultsThe microdroplet synthesis exhibited an overall decay-corrected radiochemical yield of 55 ± 7% (n = 4) after purification and formulation. When automated, the synthesis could be completed in 35 min. Starting with < 370 MBq of activity, ~ 150 MBq of [18F]FET could be produced, sufficient for multiple in vivo experiments, with high molar activities (48-119 GBq/μmol). The demonstration imaging study revealed the uptake of [18F]FET in subcutaneous tumors, but no significant differences in tumor uptake as a result of molar activity differences (ranging 0.37-48 GBq/μmol) were observed.ConclusionsA microdroplet synthesis of [18F]FET was developed demonstrating low reagent consumption, high yield, and high molar activity. The approach can be expanded to tracers other than [18F]FET, and adapted to produce higher quantities of the tracer sufficient for clinical PET imaging
Chiral logic computing with twisted antiferromagnetic magnon modes
Antiferromagnetic (AFM) materials offer an exciting platform for ultrafast information handling with low cross-talks and compatibility with existing technology. Particularly interesting for low-energy cost computing is the spin wave-based realization of logic gates, which has been demonstrated experimentally for ferromagnetic waveguides. Here, we predict chiral magnonic eigenmodes with a finite intrinsic, magnonic orbital angular momentum ℓ in AFM waveguides. ℓ is an unbounded integer determined by the spatial topology of the mode. We show how these chiral modes can serve for multiplex AFM magnonic computing by demonstrating the operation of several symmetry- and topology-protected logic gates. A Dzyaloshinskii–Moriya interaction may arise at the waveguide boundaries, allowing coupling to external electric fields and resulting in a Faraday effect. The uncovered aspects highlight the potential of AFM spintronics for swift data communication and handling with high fidelity and at a low-energy cost
- …