30 research outputs found

    4D FLOW CMR in congenital heart disease

    Get PDF
    This thesis showed that the use of a cloud-based reconstruction applicationwith advanced eddy currents correction, integrated with interactiveimaging evaluation tools allowed for remote visualization and interpretationof 4D flow data and that was sufficient for gross visualizationof aortic valve regurgitation. Further, this thesis demonstrated that bulkflow and pulmonary regurgitation can be accurately quantified using 4Dflow imaging analyzed. Peak systolic velocity over the pulmonary valvemay be underestimated. However, the measurement of peak systolicvelocity can be optimized if measured at the level of highest velocity inthe pulmonary artery. Also correlated against invasive measurements (inan animal model), this thesis shows that aorta flow and pulmonary flowcan be accurately and simultaneously measured by 4D flow MRI.When applied in clinical practice, 4D flow has extra advantages, of beingable to visualize flow pattern, vorticity and to predict aortic growth. InASD patients it can measure shunt volume directly following the septumframe by frame. In Fontan patients in can visualize better than standardMRI the Fontan circuit and it can measure flow at multiple points alongthe Fontan circuit. We observed in our Fontan population that shunt lesionswere very common, most of the time via veno-venous collaterals.Further using advanced computations, we showed that WSS angle wasthe only independent predictor of aortic growth in BAV patients. We alsoshowed the feasibility of GLS analysis on 4D flow MRI and presented anintegrative approach in which flow and functional data are acquired inone sequence.From the technical point of view, 4D flow MRI has proved to complementthe traditional components of the standard cardiac MR exams, enablingin-depth insights into hemodynamics. At this moment it proved its addedvalue, but in most of the cases it is not able yet to replace the standardexam. This is still due to long scanning times and relatively longpost-processing times.<br/

    4D FLOW CMR in congenital heart disease

    Get PDF
    This thesis showed that the use of a cloud-based reconstruction applicationwith advanced eddy currents correction, integrated with interactiveimaging evaluation tools allowed for remote visualization and interpretationof 4D flow data and that was sufficient for gross visualizationof aortic valve regurgitation. Further, this thesis demonstrated that bulkflow and pulmonary regurgitation can be accurately quantified using 4Dflow imaging analyzed. Peak systolic velocity over the pulmonary valvemay be underestimated. However, the measurement of peak systolicvelocity can be optimized if measured at the level of highest velocity inthe pulmonary artery. Also correlated against invasive measurements (inan animal model), this thesis shows that aorta flow and pulmonary flowcan be accurately and simultaneously measured by 4D flow MRI.When applied in clinical practice, 4D flow has extra advantages, of beingable to visualize flow pattern, vorticity and to predict aortic growth. InASD patients it can measure shunt volume directly following the septumframe by frame. In Fontan patients in can visualize better than standardMRI the Fontan circuit and it can measure flow at multiple points alongthe Fontan circuit. We observed in our Fontan population that shunt lesionswere very common, most of the time via veno-venous collaterals.Further using advanced computations, we showed that WSS angle wasthe only independent predictor of aortic growth in BAV patients. We alsoshowed the feasibility of GLS analysis on 4D flow MRI and presented anintegrative approach in which flow and functional data are acquired inone sequence.From the technical point of view, 4D flow MRI has proved to complementthe traditional components of the standard cardiac MR exams, enablingin-depth insights into hemodynamics. At this moment it proved its addedvalue, but in most of the cases it is not able yet to replace the standardexam. This is still due to long scanning times and relatively longpost-processing times.<br/

    Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography.

    Get PDF
    Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging

    Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Get PDF
    Objectives: To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Methods: Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Results: Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Conclusions: Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. Key Points: • The transmural perfusion ratio from dynamic CT-MPI predicts functional obstructive coronary artery disease• Performance of the transmural perfusion ratio is inferior to quantified myocardial blood flow• The incremental value of the transmural perfusion ratio is limite

    Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease

    Get PDF
    Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using t

    Left ventricular global longitudinal strain in bicupsid aortic valve patients: head-to-head comparison between computed tomography, 4D flow cardiovascular magnetic resonance and speckle-tracking echocardiography

    Get PDF
    Left ventricular global longitudinal strain (LVGLS) analysis is a sensitive measurement of myocardial deformation most often done using speckle-tracking transthoracic echocardiography (TTE). We propose a novel approach to measure LVGLS using feature-tracking software on the magnitude dataset of 4D flow cardiovascular magnetic resonance (CMR) and compare it to dynamic computed tomography (CT) and speckle tracking TTE derived measurements. In this prospective cohort study 59 consecutive adult patients with a bicuspid aortic valve (BAV) were included. The study protocol consisted of TTE, CT, and CMR on the same day. Image analysis was done using dedicated feature-tracking (4D flow CMR and CT) and speckle-tracking (TTE) software, on apical 2-, 3-, and 4-chamber long-axis multiplanar reconstructions (4D flow CMR and CT) or standard apical 2-, 3-, and 4-chamber acquisitions (TTE). CMR and CT GLS analysis was feasible in all patients. Good correlations were observed for GLS measured by CMR (− 21 ± 3%) and CT (− 20 ± 3%) versus TTE (− 20 ± 3%, Pearson’s r: 0.67 and 0.65, p 0.61, p < 0.001). Feature-tracking GLS analysis is feasible using the magnitude images acquired with 4D flow CMR. GLS measurement by CMR correlates well with CT and speckle-tracking 2D TTE. GLS analysis on 4D flow CMR allows for an integrative approach, integrating flow and functional data in a single sequence. Not applicable, observational study

    Evaluation of atrial septal defects with 4D flow MRI—multilevel and inter-reader reproducibility for quantification of shunt severity

    Get PDF
    Purpose: With the hypothesis that 4D flow can be used in evaluation of cardiac shunts, we seek to evaluate the multilevel and interreader reproducibility of measurements of the blood flow, shunt fraction and shunt volume in patients with atrial septum defect (ASD) in practice at multiple clinical sites. Materials and methods: Four-dimensional flow MRI examinations were performed at four institutions across Europe and the US. Twenty-nine patients (mean age, 43 years; 11 male) were included in the study. Flow measurements were performed at

    Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography

    Get PDF
    Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (κ = 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging
    corecore