233 research outputs found

    The effect of mass loading on spurious modes in micro-resonators

    Get PDF
    Dissipation mechanisms severely compromise the performance of micro-resonator based sensors. In this letter, we specifically examine the shift in resonant frequency of spurious modes towards the mode of interest during mass loading. This can result in modal interaction that degrades the response of the sensor. However, by understanding and controlling this effect we can overcome this key barrier to micro-resonator applications.This is the author accepted manuscript. The final version is available from AIP via http://dx.doi.org/10.1063/1.492759

    Microfluidics for protein biophysics

    Get PDF
    Microfluidics has the potential to transform experimental approaches across the life sciences. In this review, we discuss recent advances enabled by the development and application of microfluidic approaches to protein biophysics. We focus on areas where key fundamental features of microfluidics open up new possibilities and present advantages beyond low volumes and short time-scale analysis, conventionally provided by microfluidics. We discuss the two most commonly used forms of microfluidic technology, single-phase laminar flow and multiphase microfluidics. We explore how the understanding and control of the characteristic physical features of the microfluidic regime, the integration of microfluidics with orthogonal systems and the generation of well-defined microenvironments can be used to develop novel devices and methods in protein biophysics for sample manipulation, functional and structural studies, detection and material processing

    A Model for Granular Texture with Steric Exclusion

    Full text link
    We propose a new method to characterize the geometrical texture of a granular packing at the particle scale including the steric hindrance effect. This method is based on the assumption of a maximum disorder (entropy) compatible both with strain-induced anisotropy of the contact network and steric exclusions. We show that the predicted statistics for the local configurations is in a fairly agreement with our numerical data.Comment: 9 pages, 5 figure

    Mechanism of droplet-formation in a supersonic microfluidic spray device

    Get PDF
    Spray drying is an approach employed in automotive, food, and pharmaceutical industries as a robust and cost efficient liquid atomization technique offering direct control over droplet dimensions. The majority of commercially available spray nozzles are designed for large throughput spray drying applications or uniform surface coating, but microfluidic nebulizers have recently been developed as small scale alternatives. Here, we explore the physical parameters that define the droplet size and formation under supersonic flow conditions commonly found in microfluidic spray drying systems. We examined the spray nozzle operation using high speed imaging and laser scattering measurements, which allowed us to describe the spray regimes and droplet size distributions. It was determined that by using this spray nozzle device, droplets with diameters of 4–8 μm could be generated. Moreover, we show that the supersonic de Laval nozzle model can be used to predict the average droplet size. Our approach can be used as a platform for interfacing fluid microprocessing with gas phase detection and characterization

    Enhancing the resolution of micro free flow electrophoresis through spatially controlled sample injection

    Get PDF
    Free flow electrophoresis is a versatile technique for the continuous separation of mixtures with both preparative and analytical applications. Microscale versions of free flow electrophoresis are particularly attractive strategies because of their fast separation times, ability to work with small sample volumes and large surface area to volume ratios facilitating rapid heat transfer, thus minimising the detrimental effects of Joule heating even at high voltages. The resolution of microscale free flow electrophoresis, however, is limited by the broadening of the analyte beam in the microfluidic channel - an effect that becomes especially pronounced when the analyte is deflected significantly away from its original position. Here we describe and demonstrate how by spatially restricting the sample injection and collection to the regions where the gradients in the velocity distribution of the carrier medium are the smallest, this broadening effect can be substantially suppressed and hence the resolution of microscale free flow electrophoresis devices increased. To demonstrate this concept we fabricated microfluidic free flow electrophoresis devices with spatially restricted injection nozzles implemented via the use of multilayer soft-photolithography and further integrated quartz based observation areas for fluorescent detection and imaging. With these devices we demonstrated a five fold reduction in the beam broadening extent compared to conventional free flow electrophoresis approaches with non-restricted sample introduction. The manifold enhancement in the achievable resolution of microscale free flow electrophoresis devices opens up the possibility of rapid separation and analysis of more complex mixtures

    Quantifying Measurement Fluctuations from Stochastic Surface Processes on Sensors with Heterogeneous Sensitivity

    Get PDF
    Recent advances in micro- and nanotechnology have enabled the development of ultrasensitive sensors capable of detecting small numbers of species. In general, however, the response induced by the random adsorption of a small number of objects onto the surface of such sensors results in significant fluctuations due to the heterogeneous sensitivity inherent to many such sensors coupled to statistical fluctuations in the particle number. At present, this issue is addressed by considering either the limit of very large numbers of analytes, where fluctuations vanish, or the converse limit, where the sensor response is governed by individual analytes. Many cases of practical interest, however, fall between these two limits and remain challenging to analyze. Here, we address this limitation by deriving a general theoretical framework for quantifying measurement variations on mechanical resonators resulting from statistical-number fluctuations of analyte species. Our results provide insights into the stochastic processes in the sensing environment and offer opportunities to improve the performance of mechanical-resonator-based sensors. This metric can be used, among others, to aid in the design of robust sensor platforms to reach ultrahigh-resolution measurements using an array of sensors. These concepts, illustrated here in the context of biosensing, are general and can therefore be adapted and extended to other sensors with heterogeneous sensitivity.We acknowledge funding from the W. D. Armstrong fund, Biotechnology and Biological Sciences Research Council, Newman Foundation, St. John’s College–University of Cambridge, and European Research Council.This is the author accepted manuscript. The final version is available from the American Physical Society via http://dx.doi.org/10.1103/PhysRevApplied.5.06401

    Fracture driven by a Thermal Gradient

    Full text link
    Motivated by recent experiments by Yuse and Sano (Nature, 362, 329 (1993)), we propose a discrete model of linear springs for studying fracture in thin and elastically isotropic brittle films. The method enables us to draw a map of the stresses in the material. Cracks generated by the model, imposing a moving thermal gradient in the material, can branch or wiggle depending on the driving parameters. The results may be used to compare with other recent theoretical work, or to design future experiments.Comment: RevTeX file (9 pages) and 5 postscript figure

    Scalable Synthesis of Few-Layered 2D Tungsten Diselenide (2H-WSe2) Nanosheets Directly Grown on Tungsten (W) Foil Using Ambient-Pressure Chemical Vapor Deposition for Reversible Li-Ion Storage

    Get PDF
    We report a facile two-furnace APCVD synthesis of 2H-WSe2. A systematic study of the process parameters is performed to show the formation of the phase-pure material. Extensive characterization of the bulk and exfoliated material confirm that 2H-WSe2 is layered (i.e., 2D). X-ray diffraction (XRD) confirms the phase, while high-resolution scanning electron microscopy (HRSEM), high-resolution transmission electron microscopy (HRTEM), and atomic force microscopy (AFM) clarify the morphology of the material. Focused ion beam scanning electron microscopy (FIB-SEM) estimates the depth of the 2H-WSe2 formed on W foil to be around 5-8 μm, and Raman/UV-vis measurements prove the quality of the exfoliated 2H-WSe2. Studies on the redox processes of lithium-ion batteries (LiBs) show an increase in capacity up to 500 cycles. On prolonged cycling, the discharge capacity up to the 50th cycle at 250 mA/g of the material shows a stable value of 550 mAh/g. These observations indicate that exfoliated 2H-WSe2 has promising applications as an LiB electrode material

    Resolving protein mixtures using microfluidic diffusional sizing combined with synchrotron radiation circular dichroism

    Get PDF
    Circular dichroism spectroscopy has become a powerful tool to characterise proteins and other biomolecules. For heterogeneous samples such as those present for interacting proteins, typically only average spectroscopic features can be resolved. Here we overcome this limitation by using free-flow microfluidic size separation in-line with synchrotron radiation circular dichroism to resolve the secondary structure of each component of a model protein mixture containing monomers and fibrils. To enable this objective, we have integrated far-UV compatible measurement chambers into PDMS-based microfluidic devices. Two architectures are proposed so as to accommodate for a wide range of concentrations. The approach, which can be used in combination with other bulk measurement techniques, paves the way to the study of complex mixtures such as the ones associated with protein misfolding and aggregation diseases including Alzheimer’s and Parkinson’s diseases
    corecore