533 research outputs found

    Many--Particle Correlations in Relativistic Nuclear Collisions

    Get PDF
    Many--particle correlations due to Bose-Einstein interference are studied in ultrarelativistic heavy--ion collisions. We calculate the higher order correlation functions from the 2--particle correlation function by assuming that the source is emitting particles incoherently. In particular parametrizations of and relations between longitudinal, sidewards, outwards and invariant radii and corresponding momenta are discussed. The results are especially useful in low statistics measurements of higher order correlation functions. We evaluate the three--pion correlation function recently measured by NA44 and predict the 2--pion--2--kaon correlation function. Finally, many particle Coulomb corrections are discussed.Comment: 5 corrected misprints, 14 pages, revtex, epsfig, 6 figures included, manuscript also available at http://www.nbi.dk/~vischer/publications.htm

    Mnemonic Monitoring in Anosognosia for Memory Loss

    Get PDF
    Objective: Anosognosia, or unawareness, for memory loss has been proposed to underlie cognitive functions such as memory and executive function. However, there is an inconsistent association between these constructs. Recent studies have shown that compromise ongoing self-monitoring of one’s memory associates with anosognosia for memory loss. Yet to date it is unclear which memory monitoring mechanisms are impaired in these patients. In this study, we examined the extent to which temporal monitoring or orbitofrontal reality filtering (e.g., ability to monitor the temporal relevance of a memory) and source monitoring (e.g., the ability to distinguish which memories stem from internal as opposed to external sources) are associated with awareness of memory deficits. Methods: A total of 35 patients (M=69 years; M=14 years of education) with memory difficulties following a stroke were recruited from outpatient clinics. Patients were assessed with measures of self-awareness of memory difficulties, cognitive abilities and two experimental paradigms assessing source and temporal monitoring. Results and conclusion: Results showed that patients unaware of their memory difficulties were more likely to externalize the source of their memories. Specifically, those unaware of their deficits were more likely to assign an external source to memories that were internally produced (e.g., imagined). No differences were observed in relation to temporal monitoring between patients aware and unaware of their deficits. This study informs current theoretical models of self-awareness of memory loss. Future studies should attempt to replicate these findings and explore different memory monitoring mechanisms in relation to anosognosia for memory loss

    Anosognosia for prospective and retrospective memory deficits: assessment and theoretical considerations

    Get PDF
    Objective: Patients who suffer from memory loss following an Acquired Brain Injury (ABI) may also suffer from anosognosia, or unawareness of their memory loss. How we define and measure anosognosia can have critical implications for its study and clinical assessment. Commonly used measures often lack standardization and reliability checks for responses. Moreover, these methods rely heavily on cognitive abilities (e.g., language abilities) that are often affected after brain injury. The aim of this study is to elucidate how to best conceptualize and detect anosognosia for memory loss by introducing a new method of assessment, the Visual-Analogue Test for Anosognosia for memory impairment (VATAmem). Methods: A total of 51 patients (M= 61 years; M= 13 years of education) with memory difficulties following ABI were recruited from outpatient clinics. A total of 73 informants were also recruited (M= 51 years old; M= 13 years of education). Both patients and informants evaluated the severity of patients’ everyday memory mistakes on the VATAmem, for prospective and retrospective memory deficits by using visual analogue scales, vignettes and check questions to ensure reliability. Results and conclusion: A total of 30% of the patients were deemed unaware of their memory deficits. Patients were less aware of their prospective (29%) than their retrospective memory difficulties (18%). The new method of assessment provided by the VATAmem reduced possible false positives and enhanced reliability. We conclude that careful consideration of methodology is a key step to interpreting anosognosia findings within a theoretical framewor

    Prevalence, determinants, and clinical associations of high-sensitivity cardiac troponin in patients attending emergency departments

    Get PDF
    Background: High-sensitivity cardiac troponin assays may improve the diagnosis of myocardial infarction but increase the detection of elevated cardiac troponin in patients without acute coronary syndrome. Methods: In a prospective cohort study, we evaluated the prevalence, determinants, and outcome of patients with elevated cardiac troponin attending the emergency department without suspected acute coronary syndrome. We measured high-sensitivity cardiac troponin in 918 consecutive patients attending the emergency department without suspected acute coronary syndrome who had blood sampling performed by the attending clinician. Elevated high-sensitivity cardiac troponin I was defined as concentrations above the sex-specific 99th percentile threshold. Clinical demographics, physiological measures, and all-cause mortality at 1 year associated with elevated high-sensitivity cardiac troponin concentrations were recorded. Results: Elevated cardiac troponin concentration occurred in 114 (12.4%) patients, of whom 2 (0.2%), 3 (0.3%), and 109 (11.9%) were adjudicated as type 1 myocardial infarction, type 2 myocardial infarction, and myocardial injury, respectively. Elevated troponin concentrations were associated with increasing age, worsening renal function, multimorbidity, and adverse physiology. Across a total of 912 patient-years follow-up, cardiac troponin concentration was a strong predictor of death (hazard ratio [HR] 1.26 per 2-fold increase, 95% confidence interval [CI] 1.06 to 1.49) independent of age, sex, multimorbidity, and adverse physiology. Conclusions: High-sensitivity cardiac troponin concentrations were elevated in 1 in 8 consecutive patients without suspected acute coronary syndrome attending the emergency department and were associated with increasing age, multimorbidity, adverse physiology, and death. Elevated cardiac troponin in unselected patients predominantly reflects myocardial injury rather than myocardial infarction

    High-sensitivity troponin and the application of risk stratification thresholds in patients with suspected acute coronary syndrome

    Get PDF
    Background: Guidelines acknowledge the emerging role of high-sensitivity cardiac troponin (hs-cTnl) for risk stratification and the early rule-out of myocardial infarction, but multiple thresholds have been described. We evaluate the safety and effectiveness of risk stratification thresholds in patients with suspected acute coronary syndrome. Methods: Consecutive patients with suspected acute coronary syndrome (n=48 282) were enrolled in a multicenter trial across 10 hospitals in Scotland. In a prespecified secondary and observational analysis, we compared the performance of the limit of detection (<2 ng/L) and an optimized risk stratification threshold (<5 ng/L) using the Abbott high-sensitivity troponin I assay. Patients with myocardial injury at presentation, with ≀2 hours of symptoms or with ST-segment elevation myocardial infarction were excluded. The negative predictive value was determined in all patients and in subgroups for a primary outcome of myocardial infarction or cardiac death within 30 days. The secondary outcome was myocardial infarction or cardiac death at 12 months, with risk modeled using logistic regression adjusted for age and sex. Results: In total, 32 837 consecutive patients (61±17 years, 47% female) were included, of whom 23 260 (71%) and 12,716 (39%) had hs-cTnl concentrations of <5 ng/L and <2 ng/L at presentation. The negative predictive value for the primary outcome was 99.8% (95% CI, 99.7%–99.8%) and 99.9% (95% CI, 99.8%–99.9%) in those with hs-cTnl concentrations of <5 ng/L and <2 ng/L, respectively. At both thresholds, the negative predictive value was consistent in men and women and across all age groups, although the proportion of patients identified as low risk fell with increasing age. Compared with patients with hs-cTnl concentrations of ≄5 ng/L but <99th centile, the risk of myocardial infarction or cardiac death at 12 months was 77% lower in those <5 ng/L (5.3% vs 0.7%; adjusted odds ratio, 0.23 [95% CI, 0.19–0.28]) and 80% lower in those <2 ng/L (5.3% vs 0.3%; adjusted odds ratio, 0.20 [95% CI, 0.14–0.29]). Conclusions: Use of risk stratification thresholds for hs-cTnl identify patients with suspected acute coronary syndrome and at least 2 hours of symptoms as low risk at presentation irrespective of age and sex

    Implementation of a high sensitivity cardiac troponin i assay and risk of myocardial infarction or death at five years:Observational analysis of a stepped wedge, cluster randomised controlled trial

    Get PDF
    Abstract:Objective: To evaluate the impact of implementing a high sensitivity assay for cardiac troponin I on long term outcomes in patients with suspected acute coronary syndrome. Design: Secondary observational analysis of a stepped wedge, cluster randomised controlled trial. Setting: 10 secondary and tertiary care centres in Scotland, UK. Participants: 48 282 consecutive patients with suspected acute coronary syndrome. Myocardial injury was defined as any high sensitivity assay result for cardiac troponin I &gt;99th centile of 16 ng/L in women and 34 ng/L in men. Intervention: Hospital sites were randomly allocated to either early (n=5 hospitals) or late (n=5 hospitals) implementation of a high sensitivity cardiac troponin I assay with sex specific diagnostic thresholds. Main outcome measure: The main outcome was myocardial infarction or death at five years. Results: 10 360 patients had cardiac troponin concentrations greater than the 99th centile, of whom 1771 (17.1%) were reclassified by the high sensitivity assay. The five year incidence of subsequent myocardial infarction or death before and after implementation of the high sensitivity assay was 29.4% (5588/18 978) v 25.9% (7591/29 304), respectively, in all patients (adjusted hazard ratio 0.97, 95% confidence interval 0.93 to 1.01), and 63.0% (456/720) v 53.9% (567/1051), respectively, in those reclassified by the high sensitivity assay (0.82, 0.72 to 0.94). After implementation of the high sensitivity assay, a reduction in subsequent myocardial infarction or death was observed in patients with non-ischaemic myocardial injury (0.83, 0.75 to 0.91) but not in those with type 1 or type 2 myocardial infarction (0.92, 0.83 to 1.01 and 0.98, 0.84 to 1.14). Conclusions: Implementation of a high sensitivity cardiac troponin I assay in the assessment of patients with suspected acute coronary syndrome was associated with a reduced risk of subsequent myocardial infarction or death at five years in those reclassified by the high sensitivity assay. Improvements in outcome were greatest in patients with non-ischaemic myocardial injury, suggesting a broader benefit beyond the identification of myocardial infarction. Trial registration: ClinicalTrials.gov NCT01852123.</p

    Microscopic study of freeze-out in relativistic heavy ion collisions at SPS energies

    Full text link
    The freeze-out conditions in the light (S+S) and heavy (Pb+Pb) colliding systems of heavy nuclei at 160 AGeV/cc are analyzed within the microscopic Quark Gluon String Model (QGSM). We found that even for the most heavy systems particle emission takes place from the whole space-time domain available for the system evolution, but not from the thin ''freeze-out hypersurface", adopted in fluid dynamical models. Pions are continuously emitted from the whole volume of the reaction and reflect the main trends of the system evolution. Nucleons in Pb+Pb collisions initially come from the surface region. For both systems there is a separation of the elastic and inelastic freeze-out. The mesons with large transverse momenta, ptp_t, are predominantly produced at the early stages of the reaction. The low ptp_t-component is populated by mesons coming mainly from the decay of resonances. This explains naturally the decreasing source sizes with increasing ptp_t, observed in HBT interferometry. Comparison with S+S and Au+Au systems at 11.6 AGeV/cc is also presented.Comment: REVTEX, 26 pages incl. 9 figures and 2 tables, to be published in the Physical Review

    Long Term Outcomes in Patients with Type 2 Myocardial Infarction and Myocardial Injury

    Get PDF
    Background—Type 2 myocardial infarction and myocardial injury are common in clinical practice, but long-term consequences are uncertain. We aimed to define long-term outcomes and explore risk stratification in patients with type 2 myocardial infarction and myocardial injury. Methods—We identified consecutive patients (n=2,122) with elevated cardiac troponin I concentrations (≄0.05 ÎŒg/L) at a tertiary cardiac center. All diagnoses were adjudicated as per the Universal Definition of Myocardial Infarction. The primary outcome was all-cause death. Secondary outcomes included major adverse cardiovascular events (MACE; non-fatal myocardial infarction or cardiovascular death) and non-cardiovascular death. To explore competing risks, cause-specific hazard ratios were obtained using Cox regression models. Results—The adjudicated index diagnosis was type 1 or type 2 myocardial infarction or myocardial injury in 1,171 (55.2%), 429 (20.2%) and 522 (24.6%) patients, respectively. At five years, all-cause death rates were higher in those with type 2 myocardial infarction (62.5%) or myocardial injury (72.4%) compared with type 1 myocardial infarction (36.7%). The majority of excess deaths in those with type 2 myocardial infarction or myocardial injury were due to non-cardiovascular causes (HR 2.32, 95%CI 1.92-2.81, versus type 1 myocardial infarction). Despite this, the observed crude MACE rates were similar between groups (30.6% versus 32.6%), with differences apparent after adjustment for co-variates (HR 0.82, 95%CI 0.69-0.96). Coronary heart disease was an independent predictor of MACE in those with type 2 myocardial infarction or myocardial injury (HR 1.71, 95%CI 1.31-2.24). Conclusions—Despite an excess in non-cardiovascular death, patients with type 2 myocardial infarction or myocardial injury have a similar crude rate of major adverse cardiovascular events to those with type 1 myocardial infarction. Identifying underlying coronary heart disease in this vulnerable population may help target therapies that could modify future risk

    Bose-Einstein Correlations of Charged Kaons in Central Pb+Pb Collisions at Ebeam=158AGeVE_{beam} = 158 AGeV

    Get PDF
    Bose-Einstein correlations of charged kaons were measured near mid-rapidity in central Pb+Pb collisions at 158 A⋅\cdotGeV by the NA49 experiment at the CERN SPS. Source radii were extracted using the Yano-Koonin-Podgoretsky and Bertsch-Pratt parameterizations. The results are compared to published pion data. The measured m⊄m_\perp dependence for kaons and pions is consistent with collective transverse expansion of the source and a freeze-out time of about 9.5 fmfm.Comment: 14 pages with 7 figures, submitted to Phys. Lett.
    • 

    corecore