15 research outputs found

    Validity and reproducibility of retinal arteriole and venule diameter measurements : ELSA-Brasil study : a cross-sectional study

    Get PDF
    BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 μm (95% CI -0.17‑0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 μm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55‑0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55‑0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil

    Reproducibility of left ventricular mass by echocardiogram in the ELSA-Brasil

    Get PDF
    Fundamento: A ecocardiografia, apesar de não invasiva e de relativo baixo custo, tem na variabilidade de medidas repetidas um dos principais limitantes a sua utilização em estudos epidemiológicos. Objetivo: Avaliar a reprodutibilidade da massa ventricular esquerda obtida em centros de investigação (on-line) com aquela obtida em centro de leitura (off-line) e entre medidas realizadas por diferentes avaliadores no centro de leitura. Método: Ecocardiografistas dos seis centros de investigação do ELSA-Brasil mediram on-line a massa ventricular esquerda e outras medidas ecocardiográficas de 124 exames antes de enviá-los ao centro de leitura, onde foram lidos off-line de acordo com o protocolo do estudo. Metade desses exames foi medida de forma cega por um segundo leitor. Resultados: Dos 124 exames, cinco (4%) foram considerados não mensuráveis. Dos 119 restantes, 72 (61%) eram de mulheres, com idade média de 50,2 ± 7,0 anos, sendo apenas dois exames com alteração estrutural cardíaca. Em 110 (92,4%) dos exames, as imagens foram consideradas ótimas/boas pelo centro de leitura. Não foram observadas diferenças significativas entre as médias da massa ventricular esquerda obtidas on-line e off-line (1,29 g, IC 95% −3,60-6,19), sendo o coeficiente de correlação intraclasse de 0,79 (IC 95% 0,72-0,85). Para as medidas realizadas no centro de leitura, % 0,78-0,91). Conclusão: Não houve diferenças sistemáticas relevantes na medida da massa ventricular esquerda on-line versus off-line e a reprodutibilidade das medidas foi similar à de estudos anteriores. A realização das medidas em centros de leitura, como utilizado no ELSA-Brasil, é factível e útil em estudos clínico-epidemiológicos realizados em nosso meio.Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objectives: To evaluate left ventricular mass reproducibility when assessed at acquisition (online) compared to when assessed at a reading center after electronic transmission (offline) and also when assessed by different readers at the reading center. Method: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4%) were considered not measurable. Among the remaining 119, 72 (61%) were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/good by the reading center for 110 (92.4%) cases. No significant difference existed between online and offline measurements (1,29g, CI 95% −3.60-6.19), and the intraclass correlation coefficientbetween them was 0.79 (CI 95% 0.71-0.85). For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91). Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting

    Identifying individuals at high risk for diabetes : the atherosclerosis risk in communities study

    No full text
    OBJECTIVE—To develop and evaluate clinical rules to predict risk for diabetes in middle-aged adults. RESEARCH DESIGN AND METHODS—The Atherosclerosis Risk in Communities is a cohort study conducted from 1987–1989 to 1996–1998. We studied 7,915 participants 45–64 years of age, free of diabetes at baseline, and ascertained 1,292 incident cases of diabetes by clinical diagnosis or oral glucose tolerance testing. RESULTS—We derived risk functions to predict diabetes using logistic regression in a random half of the sample. Rules based on these risk functions were evaluated in the other half. A risk function based on waist, height, hypertension, blood pressure, family history of diabetes, ethnicity, and age was performed similarly to one based on fasting glucose (area under the receiver-operating characteristic curve [AUC] 0.71 and 0.74, respectively; P = 0.2). Risk functions composed of the clinical variables plus fasting glucose (AUC 0.78) and additionally including triglycerides and HDL cholesterol (AUC 0.80) performed better (P < 0.001). Evaluation of scores based on the metabolic syndrome as defined by the National Cholesterol Education Program or with slight variations showed AUCs of 0.75 and 0.78, respectively. Rules based on all these approaches, while identifying 20–56% of the sample as screen positive, achieved sensitivities of 40–87% and specificities of 50–86%. CONCLUSIONS—Rules derived from clinical information, alone or combined with simple laboratory measures, can characterize degrees of diabetes risk in middle-aged adults, permitting preventive actions of appropriate intensity. Rules based on the metabolic syndrome are reasonable alternatives to rules derived from risk functions

    Validity and reproducibility of retinal arteriole and venule diameter measurements : ELSA-Brasil study: a cross-sectional study

    Get PDF
    BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 μm (95% CI -0.17‑0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 μm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55‑0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55‑0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil

    Validity and reproducibility of retinal arteriole and venule diameter measurements : ELSA-Brasil study: a cross-sectional study

    No full text
    BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 μm (95% CI -0.17‑0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 μm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55‑0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55‑0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil

    Reproducibility of left ventricular mass by echocardiogram in the ELSA-Brasil

    No full text
    Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objective: To evaluate left ventricular mass reproducibility when assessed at acquisition (online) compared to when assessed at a reading center after electronic transmission (offline) and also when assessed by different readers at the reading center. Methods: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4%) were considered not measurable. Among the remaining 119, 72 (61%) were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/ good by the reading center for 110 (92.4%) cases. No significant difference existed between online and offline measurements (1,29 g, CI 95% −3.60-6.19), and the intraclass correlation coefficient between them was 0.79 (CI 95% 0.71-0.85). For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91). Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting

    Reproducibility of left ventricular mass by echocardiogram in the ELSA-Brasil

    Get PDF
    Fundamento: A ecocardiografia, apesar de não invasiva e de relativo baixo custo, tem na variabilidade de medidas repetidas um dos principais limitantes a sua utilização em estudos epidemiológicos. Objetivo: Avaliar a reprodutibilidade da massa ventricular esquerda obtida em centros de investigação (on-line) com aquela obtida em centro de leitura (off-line) e entre medidas realizadas por diferentes avaliadores no centro de leitura. Método: Ecocardiografistas dos seis centros de investigação do ELSA-Brasil mediram on-line a massa ventricular esquerda e outras medidas ecocardiográficas de 124 exames antes de enviá-los ao centro de leitura, onde foram lidos off-line de acordo com o protocolo do estudo. Metade desses exames foi medida de forma cega por um segundo leitor. Resultados: Dos 124 exames, cinco (4%) foram considerados não mensuráveis. Dos 119 restantes, 72 (61%) eram de mulheres, com idade média de 50,2 ± 7,0 anos, sendo apenas dois exames com alteração estrutural cardíaca. Em 110 (92,4%) dos exames, as imagens foram consideradas ótimas/boas pelo centro de leitura. Não foram observadas diferenças significativas entre as médias da massa ventricular esquerda obtidas on-line e off-line (1,29 g, IC 95% −3,60-6,19), sendo o coeficiente de correlação intraclasse de 0,79 (IC 95% 0,72-0,85). Para as medidas realizadas no centro de leitura, % 0,78-0,91). Conclusão: Não houve diferenças sistemáticas relevantes na medida da massa ventricular esquerda on-line versus off-line e a reprodutibilidade das medidas foi similar à de estudos anteriores. A realização das medidas em centros de leitura, como utilizado no ELSA-Brasil, é factível e útil em estudos clínico-epidemiológicos realizados em nosso meio.Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objectives: To evaluate left ventricular mass reproducibility when assessed at acquisition (online) compared to when assessed at a reading center after electronic transmission (offline) and also when assessed by different readers at the reading center. Method: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4%) were considered not measurable. Among the remaining 119, 72 (61%) were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/good by the reading center for 110 (92.4%) cases. No significant difference existed between online and offline measurements (1,29g, CI 95% −3.60-6.19), and the intraclass correlation coefficientbetween them was 0.79 (CI 95% 0.71-0.85). For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91). Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting

    Timing and Type of Alcohol Consumption and the Metabolic Syndrome - ELSA-Brasil

    Get PDF
    <div><p>The prevalence of the metabolic syndrome is rising worldwide. Its association with alcohol intake, a major lifestyle factor, is unclear, particularly with respect to the influence of drinking with as opposed to outside of meals. We investigated the associations of different aspects of alcohol consumption with the metabolic syndrome and its components. In cross-sectional analyses of 14,375 active or retired civil servants (aged 35–74 years) participating in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil), we fitted logistic regression models to investigate interactions between the quantity of alcohol, the timing of its consumption with respect to meals, and the predominant beverage type in the association of alcohol consumption with the metabolic syndrome. In analyses adjusted for age, sex, educational level, income, socioeconomic status, ethnicity, smoking, body mass index, and physical activity, light consumption of alcoholic beverages with meals was inversely associated with the metabolic syndrome (≤4 drinks/week: OR = 0.85, 95%CI 0.74–0.97; 4 to 7 drinks/week: OR = 0.75, 95%CI 0.61–0.92), compared to abstention/occasional drinking. On the other hand, greater consumption of alcohol consumed outside of meals was significantly associated with the metabolic syndrome (7 to 14 drinks/week: OR = 1.32, 95%CI 1.11–1.57; ≥14 drinks/week: OR = 1.60, 95%CI 1.29–1.98). Drinking predominantly wine, which occurred mostly with meals, was significantly related to a lower syndrome prevalence; drinking predominantly beer, most notably when outside of meals and in larger quantity, was frequently associated with a greater prevalence. In conclusion, the alcohol—metabolic syndrome association differs markedly depending on the relationship of intake to meals. Beverage preference—wine or beer—appears to underlie at least part of this difference. Notably, most alcohol was consumed in metabolically unfavorable type and timing. If further investigations extend these findings to clinically relevant endpoints, public policies should recommend that alcohol, when taken, should be preferably consumed with meals.</p></div

    Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil)

    Get PDF
    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008–2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31–0.65) and serum potassium (ICC=0.73; 95%CI=0.60–0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements
    corecore