15 research outputs found

    Prototype implementation and experimental analysis of water heating using recovered waste heat of chimneys

    No full text
    This work discusses a waste heat recovery system (WHRS) applied to chimneys for heating water in residential buildings. A prototype illustrating the suggested system is implemented and tested. Different waste heat scenarios by varying the quantity of burned firewood (heat input) are experimented. The temperature at different parts of the WHRS and the gas flow rates of the exhaust pipes are measured. Measurements showed that the temperature of 95 L tank of water can be increased by 68 °C within one hour. Obtained results show that the convection and radiation exchanges at the bottom surface of the tank have a considerable impact on the total heat transfer rate of the water (as high as 70%)

    Correction notice to: Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head

    Get PDF
    Introduction: Osteonecrosis of the femoral head (ONFH) remains a therapeutic challenge for patients undergoing total hip arthroplasty (THA). The majority of these patients are young with high functional demand, and show an increased risk of dislocation following surgery than patients with osteoarthritis. The use of double mobility cup (DMC) has been linked with lower rates of complications when compared to conservative cups; however, the literature is scarce over DMC results in patients with ONFH. The aim of the study is to report the early outcomes of patients with ONFH treated with THA-DMC. Materials: A retrospective analysis of patients suffering from ONFH who underwent THA using DMC (THA-DMC) from 2006 to 2015 were evaluated for functional status and risk of post-operative complications. Thirty THA-DMC in 26 patients with a mean follow-up of 51 months were evaluated clinically (modified Hip Harris Score) and radiologically. Results: The mean age of the included patients was 54.9 years. At final follow-up, the mean modified Hip Harris score was 98.7 ± 2.7 and no dislocation episodes or revision surgeries were recorded. The radiological assessment revealed no signs of migration/tilting, radiolucent lines, periprosthetic osteolysis or heterotopic ossification over the DMC component and the femoral stem. The survival rate over 51 months of follow-up was 100%. Discussion: The use of the new generation of dual mobility cup in patients with ONFH showed excellent functional early results with no major complications such as dislocation

    Current concepts in robotic total hip arthroplasty

    No full text
    Introduction: Total hip replacement provides mostly fair functional and clinical results. Many factors play an essential role in hip stability and long-term outcomes. Surgical positioning remains fundamental for obtaining accurate implant fit and prevent hip dislocation or impingement. Different categories of robotic assistance have been established throughout the previous years and all of the technologies target accuracy and reliability to reduce complications, and enhance clinical outcomes. Materials and methods: An overview is proposed over the principles of robotic assistance in hip arthroplasty surgery. Accuracy, reliability, management of the bone stock, clinical outcomes, constraints and limits of this technology are reported, based on recent literature. Results: Potential advantages regarding pre-operative planning accuracy, cup positioning, maintenance of the center of rotation, preservation of an adequate bone stock nay clinical short- and mid-term outcomes are balanced with some reported disadvantages and limits like hip anatomical specificity, cost-effectiveness, engineering dependence. Discussion: The use of robotic-assisted THA presents clear and evident benefits related to accurate implant positioning and maintenance of a minimal bone while allowing. For some authors, an early improvement in functional results and patient’s recovery. This technology demonstrated a shorter surgical time and a short learning curve required to optimize its use and this technology presents promising outcomes and results and potential use in routine clinical application but its limitation of use is still present especially the cost of the robot, the need for the presence of an engineer during the surgery, its availability of use in all hospitals as well as the difficulty presented in dysplastic or dysmorphic hip joints

    Outcomes of total hip arthroplasty using dual mobility cups following failed internal fixation of proximal femoral fractures at a mean follow-up of 6 years

    No full text
    Introduction: Performing total hip arthroplasty (THA) after failed internal fixation of proximal femoral fractures (PFF) is known to be associated with high rates of complications. Dual mobility cups (DMC) are known to lower dislocation events in high-risk patients. Very few reports investigated the outcomes of THA using DMC following failure of internal fixation for PFF. Methods: This is a retrospective monocentric continuous study of 31 patients who underwent THA with DMC after failed internal fixation of PFF. The clinical assessment was based on the modified Harris hip score (mHHS) at the last follow-up. The complication rates and radiological analyses were recorded. Results: The mean follow-up period was 5.96 ± 4.2 years. At the last follow-up, the mean mHHS was 92.9 ± 9.1 with 71% of the patients describing their operated hip as a forgotten hip. No dislocation or aseptic loosening events were noted. One patient developed a septic loosening of the implant. No significant radiological changes were recorded. Sixteen stems (51.6%) were placed in a neutral position, 13 (42%) in valgus (2.74 ± 1.72°), and 2 (6.4%) in varus (6.94 ± 2.02°). Conclusion: This study emphasizes the advantage of using DMC following failed internal fixation of PFF in reducing dislocation and complication events in this high-risk population
    corecore