463 research outputs found

    Seismic Vulnerability of the Italian Roadway Bridge Stock

    Get PDF
    This study focuses on the seismic vulnerability evaluation of the Italian roadway bridge stock, within the framework of a Civil Protection sponsored project. A comprehensive database of existing bridges (17,000 bridges with different level of knowledge) was implemented. At the core of the study stands a procedure for automatically carrying out state-of-the-art analytical evaluation of fragility curves for two performance levels – damage and collapse – on an individual bridge basis. A webGIS was developed to handle data and results. The main outputs are maps of bridge seismic risk (from the fragilities and the hazard maps) at the national level and real-time scenario damage-probability maps (from the fragilities and the scenario shake maps). In the latter case the webGIS also performs network analysis to identify routes to be followed by rescue teams. Consistency of the fragility derivation over the entire bridge stock is regarded as a major advantage of the adopted approach

    Diverse effects of natural and synthetic surfactants on the inhibition of staphylococcus aureus biofilm

    Get PDF
    A major challenge in the biomedical field is the creation of materials and coating strategies that effectively limit the onset of biofilm-associated infections on medical devices. Biosurfactants are well known and appreciated for their antimicrobial/anti-adhesive/anti-biofilm properties, low toxicity, and biocompatibility. In this study, the rhamnolipid produced by Pseudomonas aeruginosa 89 (R89BS) was characterized by HPLC-MS/MS and its ability to modify cell surface hydrophobicity and membrane permeability as well as its antimicrobial, anti-adhesive, and anti-biofilm activity against Staphylococcus aureus were compared to two commonly used surfactants of synthetic origin: Tween® 80 and Triton™ X-100. The R89BS crude extract showed a grade of purity of 91.4% and was composed by 70.6% of mono-rhamnolipids and 20.8% of di-rhamnolipids. The biological activities of R89BS towards S. aureus were higher than those of the two synthetic surfactants. In particular, the anti-adhesive and anti-biofilm properties of R89BS and of its purified mono-and di-congeners were similar. R89BS inhibition of S. aureus adhesion and biofilm formation was ~97% and 85%, respectively, and resulted in an increased inhibition of about 33% after 6 h and of about 39% after 72 h when compared to their chemical counterparts. These results suggest a possible applicability of R89BS as a protective coating agent to limit implant colonization

    In-stent restenosis of superficial femoral artery: use all arrows in the quiver.

    Get PDF
    In-stent restenosis (ISR) is a common superficial femoral artery (SFA) stenting complication, occurring in more than one third of patients within 2-3 years after the index procedure. Moreover, there is no standard treatment for ISR, and although many options are available, there is still limited data regarding its optimal management. We report a paradigmatic case report of a patient complaining of symptomatic peripheral arterial disease, underwent multiple endovascular revascularizations for recurrent femoro-popliteal ISR. A step-by-step approach was followed. At the time of the first presentation, the ISR was treated by drug-eluting balloon (DEB) angioplasty. The repeated ISR was treated by laser debulking, achieving a good angiographic result. Finally, after the third repeated restenosis, a combined approach with laser debulking and DEB angioplasty guaranteed a good acute angiographic result. Long-term duplex-scan follow-up demonstrated the good patency of the femoro-popliteal target lesion

    Computational evaluation of cochlear implant surgery outcomes accounting for uncertainty and parameter variability

    Get PDF
    Cochlear implantation (CI) is a complex surgical procedure that restores hearing in patients with severe deafness. The successful outcome of the implanted device relies on a group of factors, some of them unpredictable or difficult to control. Uncertainties on the electrode array position and the electrical properties of the bone make it difficult to accurately compute the current propagation delivered by the implant and the resulting neural activation. In this context, we use uncertainty quantification methods to explore how these uncertainties propagate through all the stages of CI computational simulations. To this end, we employ an automatic framework, encompassing from the finite element generation of CI models to the assessment of the neural response induced by the implant stimulation. To estimate the confidence intervals of the simulated neural response, we propose two approaches. First, we encode the variability of the cochlear morphology among the population through a statistical shape model. This allows us to generate a population of virtual patients using Monte Carlo sampling and to assign to each of them a set of parameter values according to a statistical distribution. The framework is implemented and parallelized in a High Throughput Computing environment that enables to maximize the available computing resources. Secondly, we perform a patient-specific study to evaluate the computed neural response to seek the optimal post-implantation stimulus levels. Considering a single cochlear morphology, the uncertainty in tissue electrical resistivity and surgical insertion parameters is propagated using the Probabilistic Collocation method, which reduces the number of samples to evaluate. Results show that bone resistivity has the highest influence on CI outcomes. In conjunction with the variability of the cochlear length, worst outcomes are obtained for small cochleae with high resistivity values. However, the effect of the surgical insertion length on the CI outcomes could not be clearly observed, since its impact may be concealed by the other considered parameters. Whereas the Monte Carlo approach implies a high computational cost, Probabilistic Collocation presents a suitable trade-off between precision and computational time. Results suggest that the proposed framework has a great potential to help in both surgical planning decisions and in the audiological setting process

    Medical-grade silicone coated with rhamnolipid R89 is effective against Staphylococcus spp. Biofilms

    Get PDF
    Staphylococcus aureus and Staphylococcus epidermidis are considered two of the most important pathogens, and their biofilms frequently cause device-associated infections. Microbial biosurfactants recently emerged as a new generation of anti-adhesive and anti-biofilm agents for coating implantable devices to preserve biocompatibility. In this study, R89 biosurfactant (R89BS) was evaluated as an anti-biofilm coating on medical-grade silicone. R89BS is composed of homologues of the mono- (75%) and di-rhamnolipid (25%) families, as evidenced by mass spectrometry analysis. The antimicrobial activity against Staphylococcus spp. planktonic and sessile cells was evaluated by microdilution and metabolic activity assays. R89BS inhibited S. aureus and S. epidermidis growth with minimal inhibitory concentrations (MIC99) of 0.06 and 0.12 mg/mL, respectively and dispersed their pre-formed biofilms up to 93%. Silicone elastomeric discs (SEDs) coated by R89BS simple adsorption significantly counteracted Staphylococcus spp. biofilm formation, in terms of both built-up biomass (up to 60% inhibition at 72 h) and cell metabolic activity (up to 68% inhibition at 72 h). SEM analysis revealed significant inhibition of the amount of biofilm-covered surface. No cytotoxic effect on eukaryotic cells was detected at concentrations up to 0.2 mg/mL. R89BS-coated SEDs satisfy biocompatibility requirements for leaching products. Results indicate that rhamnolipid coatings are effective anti-biofilm treatments and represent a promising strategy for the prevention of infection associated with implantable devices

    The Reliability of Anamnestic Data in the Management of Clostridium Tetani Infection in Elderly

    Get PDF
    Background: Tetanus infection remains a significant complication of wounds. Because most tetanus treatment guidelines rely on anamnestic data collected directly from patients, the congruence between anamnesis and laboratory evidence must be verified, especially in the elderly population. Aim: Assess, in both the geriatric population (>65) and the non-geriatric one, the reliability of anamnestic data for managing patients with tetanus-risk wounds, identified categories of populations most exposed to non-vaccination coverage, and assessed the agreement of the Tetanos Quick Stick (TQS) results with the therapy performed (administration of tetanus vaccine or immunoglobulin). Methods: In this retrospective single-center observational study, patients were asked their immunization status against tetanus vaccination. The decision to administer a vaccine or immunoglobulin was therefore clinical and based on anamnestic criteria. The TQS test was then given to patients who were unaware of their immunity status. Patients who thought they knew it but were not sure were given the TQS test to determine whether the anamnestic collection was supported by the test. The TQS test results were compared with the anamnestic data. Results: Most patients, geriatric and not geriatric, did not know their immune status. Among those who reported knowing their immune status, there was no agreement between the vaccine coverage declared by patients and the TQS test results (p < 0.001), mainly in geriatric patients but also in the control group. Elderly and women had significantly lower positive TQS test results (p < 0.001). There was a statistically significant discrepancy (p < 0.001) between the therapy based on anamnestic data and the TQS test results. Conclusion: The reliability of anamnestic data for the management of patients with tetanus-risk wounds is low and decreases with age, becoming minimal in geriatric patients. Elderly and women are less likely to have an effective vaccination status against tetanus

    The ALICE silicon pixel detector read-out electronics

    Get PDF
    The ALICE silicon pixel detector (SPD) constitutes the two innermost layers of the ALICE inner tracker system. The SPD contains 10 million pixels segmented in 120 detector modules (half staves), which are connected to the offdetector electronics with bidirectional optical links. Raw data from the on-detector electronics are sent to 20 FPGA-based processor cards (Routers) each carrying three 2-channel linkreceiver daughter-cards. The routers process the data and send them to the ALICE DAQ system via the ALICE detector data link (DDL). The SPD control, configuration and data monitoring is performed via the VME interface of the routers. This paper describes the detector readout and control via the off-detector electronics

    Performance of ALICE pixel prototypes in high energy beams

    Full text link
    The two innermost layers of the ALICE inner tracking system are instrumented with silicon pixel detectors. Single chip assembly prototypes of the ALICE pixels have been tested in high energy particle beams at the CERN SPS. Detection efficiency and spatial precision have been studied as a function of the threshold and the track incidence angle. The experimental method, data analysis and main results are presented.Comment: 10 pages, 9 figures, contribution to PIX2005 Workshop, Bonn (Germany), 5-8 September 200
    • …
    corecore