55 research outputs found

    Varieties of size-specific visual selection.

    Get PDF

    Eye movements during information processing tasks: Individual differences and cultural effects

    Get PDF
    AbstractThe eye movements of native English speakers, native Chinese speakers, and bilingual Chinese/English speakers who were either born in China (and moved to the US at an early age) or in the US were recorded during six tasks: (1) reading, (2) face processing, (3) scene perception, (4) visual search, (5) counting Chinese characters in a passage of text, and (6) visual search for Chinese characters. Across the different groups, there was a strong tendency for consistency in eye movement behavior; if fixation durations of a given viewer were long on one task, they tended to be long on other tasks (and the same tended to be true for saccade size). Some tasks, notably reading, did not conform to this pattern. Furthermore, experience with a given writing system had a large impact on fixation durations and saccade lengths. With respect to cultural differences, there was little evidence that Chinese participants spent more time looking at the background information (and, conversely less time looking at the foreground information) than the American participants. Also, Chinese participants’ fixations were more numerous and of shorter duration than those of their American counterparts while viewing faces and scenes, and counting Chinese characters in text

    Adding depth to overlapping displays can improve visual search performance

    Get PDF
    Standard models of visual search have focused upon asking participants to search for a single target in displays where the objects do not overlap one another, and where the objects are presented on a single depth plane. This stands in contrast to many everyday visual searches wherein variations in overlap and depth are the norm, rather than the exception. Here, we addressed whether presenting overlapping objects on different depths planes to one another can improve search performance. Across four different experiments using different stimulus types (opaque polygons, transparent polygons, opaque real-world objects, and transparent X-ray images), we found that depth was primarily beneficial when the displays were transparent, and this benefit arose in terms of an increase in response accuracy. Although the benefit to search performance only appeared in some cases, across all stimulus types, we found evidence of marked shifts in eye-movement behavior. Our results have important implications for current models and theories of visual search, which have not yet provided detailed accounts of the effects that overlap and depth have on guidance and object identification processes. Moreover, our results show that the presence of depth information could aid real-world searches of complex, overlapping displays

    Using Eye Movements to Understand how Security Screeners Search for Threats in X-Ray Baggage.

    Get PDF
    There has been an increasing drive to understand failures in searches for weapons and explosives in X-ray baggage screening. Tracking eye movements during the search has produced new insights into the guidance of attention during the search, and the identification of targets once they are fixated. Here, we review the eye-movement literature that has emerged on this front over the last fifteen years, including a discussion of the problems that real-world searchers face when trying to detect targets that could do serious harm to people and infrastructure

    In vitro prediction of polycyclic aromatic hydrocarbon bioavailability of 14 different incidentally ingested soils in juvenile swine

    Get PDF
    Predicting mammalian bioavailability of PAH mixtures from in vitro bioaccessibility results has proven to be an elusive goal. In an attempt to improve in vitro predictions of PAH soil bioavailability we investigated how energetic input influences PAH bioaccessibility by using a high and low energetic shaking method. Co-inertia analysis (COIA), and Structural Equation Modeling (SEM) were also used to examine PAH-PAH interactions during ingestion. PAH bioaccessibility was determined from 14 historically contaminated soils using the fed organic estimation of the human simulation test (FOREhST) with inclusion of a silicone rod as a sorption sink and compared to bioavailability estimates from the juvenile swine model. Shaking method significantly affected PAH bioaccessibility in the FOREhST model, with PAH desorption from the high energy FOREhST almost an order of magnitude greater compared to the low energy FOREhST. PAH-PAH interactions significantly influenced PAH bioavailability and when these interactions were used in a linear model, the model predicted benzo(a)anthracene bioavailability with an slope of 1 and r2 of 0.66 and for benzo(a)pyrene bioavailability has a slope of 1 and r2 of 0.65. Lastly, to confirm the effects as determined by COIA and SEM, we spiked low levels of benzo(a)anthracene into historically contaminated soils, and observed a significant increase in benzo(a)pyrene bioaccessibility. By accounting for PAH interactions, and reducing the energetics of in vitro extractions, we were able to use bioaccessibility to predict bioavailability across 14 historically contaminated soils. Our work suggests that future work on PAH bioavailability and bioaccessibility should focus on the dynamics of how the matrix of PAHs present in the soil interact with mammalian systems. Such interactions should not only include the chemical interactions discussed here but also the interactions of PAH mixtures with mammalian uptake systems

    We can guide search by a set of colours, but are reluctant to do it.

    Get PDF
    For some real-world color searches, the target colours are not precisely known, and any item within a range of color values should be attended. This, a target representation that captures multiple similar colours would be advantageous. If such multicolour search is possible, then search for two targets (e..g Stroud, Menneer, Cave and Donnelly, 2012) might be guided by a target representation that included the target colours as well as the continuum of colours that fall between the targets within a contiguous region of color space. Results from Stroud et al (2012) suggest otherwise, however. The current set of experiments show that guidance for a set of colours that are from a single region of color space can be effective if targets are depicted as specific discrete colours. Specifically, Experiments 1-3 demonstrate that a search can be guided by four and even eight colours given the appropriate conditions. However, Experiment 5 gives evidence that guidance is sometimes sensitive to how informative the target preview is to search. Experiments 6 and 7 show that a stimulus showing a continuous range of target colours is not translated into a search target representation. Thus, search can be guided by multiple discrete colours that are from a single region in color space, but this approach was not adopted in a search for two targets with intervening distractor colours

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    • …
    corecore