1,692 research outputs found

    Bound state spectra of three-body muonic molecular ions

    Full text link
    The results of highly accurate calculations are presented for all twenty-two known bound S(L=0),P(L=1),D(L=2)S(L = 0)-, P(L = 1)-, D(L = 2)- and F(L=3)F(L = 3)-states in the six three-body muonic molecular ions ppμ,pdμ,ptμ,ddμ,dtμpp\mu, pd\mu, pt\mu, dd\mu, dt\mu and ttμtt\mu. A number of bound state properties of these muonic molecular ions have been determined numerically to high accuracy. The dependence of the total energies of these muonic molecules upon particle masses is considered. We also discuss the current status of muon-catalysis of nuclear fusion reactions.Comment: This is the final version. All `techical' troubles with the Latex-file have been resolved. A few misprints/mistakes in the text were correcte

    Threats to groundwater supplies from contamination in Sierra Leone, with special reference to Ebola care facilities

    Get PDF
    The outbreak of Ebola virus disease in West Africa in 2014 is the worst single outbreak recorded, and has resulted in more fatalities than all previous outbreaks combined. This outbreak has resulted in a large humanitarian effort to build new health care facilities, with associated water supplies. Although Ebola is not a water-borne disease, care facilities for Ebola patients may become sources of outbreaks of other, water-borne, diseases spread through shallow groundwater from hazard sources such as open defecation, latrines, waste dumps and burial sites to water supplies. The focus of this rapid desk study is to assess from existing literature the evidence for sub-surface transport of pathogens in the context of the hydrogeological and socio-economic environment of Sierra Leone. In particular, the outputs are to advise on the robustness of the evidence for an effective single minimum distance for lateral spacing between hazard sources and water supply, and provide recommendations for protecting water supplies for care facilities as well as other private and public water supplies in this region. Preliminary conclusions were: Considering the climate (heavy intense rainfall for 8 months), the hydrogeological conditions (prevalent shallow and rapidly fluctuating water tables, permeable tropical soils), the pervasive and widespread sources of hazards (very low improved sanitation coverage), and the widespread use of highly vulnerable water points there is little evidence that simply using an arbitrary lateral spacing between hazard sources and water point of 30 – 50 m would provide effective protection for groundwater points. An alternative framework that considers vertical as well as lateral separation and the integrity of the construction and casing of the deeper water points is recommended to protect water supplies from contamination by pathogens. The shallow aquifer, accessed by wells and springs, must be treated as highly vulnerable to pollution, both from diffuse sources and from localised sources. Diffuse pollution of groundwater from surface-deposited wastes including human excreta is likely to be at least as important as pollution from pit latrines and other point sources, given the low sanitation coverage in Sierra Leone. Even though conditions are not optimal for pathogen survival (e.g. temperatures of >25° C), given the very highly permeable shallow tropical soil zone, and the high potential surface and subsurface loading of pathogens, it is likely that shallow water sources are at risk from pathogen pollution, particularly during periods of intense rainfall and high water table conditions. Extending improved sanitation must be a high priority, in conjunction with improved vertical separation between hazard sources and water points, in order to reduce environmental contamination and provide a basis for improved public health. We recommend that risk assessments of water points are undertaken for health care facilities as soon as possible including: detailed sanitary inspections of water points within the 30 – 50 m radius suggested by the Ministry of Water Resource; assessments of the construction and integrity of the water points; a wider survey of contaminant load and rapid surface / sub surface transit routes within a wider 200 m radius of water points. Analysis of key water quality parameters and monitoring of water levels should be undertaken at each water point in parallel with the risk assessments. The translation of policy on water, sanitation and hygiene into implementation needs complementary research to understand key hydrogeological processes as well as barriers and failings of current practice for reducing contamination in water points. A baseline assessment of water quality status and sanitary risks for e.g. wells vs boreholes, improved vs unimproved sources in Sierra Leone is needed. Understanding the role of the tropical soil zone in the rapid migration of pollutants in the shallow subsurface, i.e. tracing rapid pathways, and quantifying residence times of shallow and deep groundwater systems are key knowledge gaps

    UPGRO Hidden Crisis Research consortium: unravelling past failures for future success in rural water supply: initial project approach for assessing rural water supply functionality and levels of performance

    Get PDF
    The new Sustainable Development Goals (SDGs) set a much stronger focus on sustainability and performance of water services, and have highly ambitious goals to achieve universal access to safe and reliable water for all by 2030 (UN 2013 ). Poor functionality of water points threatens to undermine progress, and a lack of knowledge for the reasons behind this make it difficult to recommend improvements and take corrective action. As a first step it is necessary to be able to reliably monitor current rates of functionality and to have a clear benchmark as to what constitutes a functional water point. Currently, there is no single accepted definition for functionality, although organisations are working towards this as a means of tracking progress towards the SDGs. This report sets out the initial work by the Hidden Crisis project to develop a framework approach to assess functionality in terms of different levels of performance, and a set of standard indicators which can be used to assess functionality. The report presents the results of a literature review examining the following questions: (1) what are the current approaches to defining functionality of hand-pump boreholes; and (2) what are the robust standards by which the functionality of a HPB, or population of HPB’s, can be assessed. From analyses of the literature we have developed preliminary guidelines and applied these to develop a preliminary framework

    Reallocating resources to focused factories: a case study in chemotherapy

    Get PDF
    This study investigates the expected service performance associated with a proposal to reallocate resources from a centralized chemotherapy department to a breast cancer focused factory. Using a slotted queueing model we show that a decrease in performance is expected and calculate the amount of additional resources required to offset these losses. The model relies solely on typical outpatient scheduling system data, making the methodology easy to replicate in other outpatient clinic settings. Finally, the paper highlights important factors to consider when assigning capacity to focused factories. These considerations are generally relevant to other resource allocation decisions

    BioConcens: Biomass and bioenergy production agriculture – consequences for soil fertility, environment, spread of animal parasites and socio-economy

    Get PDF
    The research programme called “international research cooperation and organic integrity” was commenced for a period 2006-2010. It is coordinated by DARCOF (The Danish Research Centre for Organic Farming). The whole programme, with acronym DARCOF III, consists of 15 projects (http://www.darcof.dk/research/darcofiii/index.html). One of them is BIOCONCENS - Biomass and bioenergy production in organic farming – consequences for soil fertility, environment, spread of animal parasites and socio-economy (http://www.bioconcens.elr.dk/uk/). The production of bioenergy in organic agriculture (OA) can reduce its dependency of fossil fuels and decrease green house gasses emission; consequently it will increase sustainability of organic farms. Biorefinery concept based on co-production of biogas, bioethanol and protein fodder in organic farming will be developed within the BIOCONCENS project and the background for the project and the different work packages will be presented in this paper

    Structure of the ovaries of the Nimba otter shrew, Micropotamogale lamottei, and the Madagascar hedgehog tenrec, Echinops telfairi

    Get PDF
    The otter shrews are members of the subfamily Potamogalinae within the family Tenrecidae. No description of the ovaries of any member of this subfamily has been published previously. The lesser hedgehog tenrec, Echinops telfairi, is a member of the subfamily Tenrecinae of the same family and, although its ovaries have not been described, other members of this subfamily have been shown to have ovaries with non-antral follicles. Examination of these two species illustrated that non-antral follicles were characteristic of the ovaries of both species, as was clefting and lobulation of the ovaries. Juvenile otter shrews range from those with only small follicles in the cortex to those with 300- to 400-mu m follicles similar to those seen in non-pregnant and pregnant adults. As in other species, most of the growth of the oocyte occurred when follicles had one to two layers of granulosa cells. When larger follicles became atretic in the Nimba otter shrew, hypertrophy of the theca interna produced nodules of glandular interstitial tissue. In the tenrec, the hypertrophying theca interna cells in most large follicles appeared to undergo degeneration. Both species had some follicular fluid in the intercellular spaces between the more peripheral granulosa cells. It is suggested that this fluid could aid in separation of the cumulus from the remaining granulosa at ovulation. The protruding follicles in lobules and absence of a tunica albuginea might also facilitate ovulation of non-antral follicles. Ovaries with a thin-absent tunica albuginea and follicles with small-absent antra are widespread within both the Eulipotyphla and in the Afrosoricida, suggesting that such features may represent a primitive condition in ovarian development. Lobulated and deeply crypted ovaries are found in both groups but are not as common in the Eulipotyphla making inclusion of this feature as primitive more speculative. Copyright (C) 2005 S. Karger AG, Basel

    S-branes and (Anti-)Bubbles in (A)dS Space

    Full text link
    We describe the construction of new locally asymptotically (A)dS geometries with relevance for the AdS/CFT and dS/CFT correspondences. Our approach is to obtain new solutions by analytically continuing black hole solutions. A basic consideration of the method of continuation indicates that these solutions come in three classes: S-branes, bubbles and anti-bubbles. A generalization to spinning or twisted solutions can yield spacetimes with complicated horizon structures. Interestingly enough, several of these spacetimes are nonsingular.Comment: 35 pages, 12 figures. V2: JHEP style, expanded reference

    A hidden crisis: strengthening the evidence base on the sustainability of rural groundwater supplies: results from a pilot study in Uganda

    Get PDF
    Extending and sustaining access to rural water supplies remains central to improving the health and livelihoods of poor people, particularly women, in Africa, where 400 million rural inhabitants have no form of utility provided water, and universal access to water hinges on accelerated development of groundwater (UN 2013). The ‘future proofing’ of groundwater investments is therefore vital, especially in the context of global and local trends including demographic shifts, environmental impacts of human activity and climate change (Taylor et al. 2013). The emphasis, in recent years, on accelerating access to new infrastructure has obscured a hidden crisis of failure. More than 30% of sources are non‐functional within a few years of construction (Rietveld et al. 2009, RWSN 2009, Lockwood et al. 2011) and a greater number are seasonal (for example 50% in Sierra Leone) (MoEWR 2012). The accumulated costs to governments, donors, and, above all, rural people, are enormous. The original benefits generated by the new infrastructure – improved health, nutrition, time savings, education, particularly for the poorest – are lost if improved services cannot be sustained. The cumulative effect of rural water supply failure in Africa over the past 20 years has been estimated by the World Bank to represent a lost investment in excess of $1.2 billion. Critically, there is limited data or analysis on why sources are non‐functional and therefore little opportunity to learn from past mistakes. This report provides a summary of the work undertaken by the UK‐funded UPGro research programme ('Unlocking the Potential for Groundwater for the Poor') for sub‐Saharan Africa (SSA) funded by the Natural Environment Research Council (NERC), the Economic and Social Research Council (ESRC) and the Department for International Development (DfID). The Catalyst Grant project ‘A Hidden Crisis’ was aimed at developing a methodology and toolbox to investigate the causes of failure in groundwater‐based water services in SSA, which could form the foundation for more substantial and larger‐scale research in the future to develop a statistically significant evidence base to examine water point functionality and the underlying causes of failure across a range of physical, social, institutional and governance environments in SSA. To test the toolbox and methodology developed, a pilot study was conducted in northeast Uganda Overall, the approach and methods developed in the catalyst project have been shown to make a significant step towards developing a replicable and robust methodology which can be used to generate a systematic evidence base for supply failure. The work has gone a significant way to encapsulating the complexity of the interlinked aspects of the problem, balancing the natural science and engineering (“technical”) aspects of the research with those concerning the ability of communities to manage and maintain their water points (the “social” aspects). The multiplicity of interlinked causes of water point failure was explicitly acknowledged and taken into account through the use of multi‐disciplinary field and analytical methods within the toolbox and in selection of the research team. The multi‐disciplinary methods of investigation used were highly practical and appropriate to the information sought, and based on detailed observational science

    Diquark condensation effects on hot quark star configurations

    Full text link
    The equation of state for quark matter is derived for a nonlocal, chiral quark model within the mean field approximation.We investigate the effects of a variation of the formfactors of the interaction on the phase diagram of quark matter. Special emphasis is on the occurrence of a diquark condensate which signals a phase transition to color superconductivity and its effects on the equation of state under the condition of beta- equilibrium and charge neutrality. We calculate the quark star configurations by solving the Tolman- Oppenheimer- Volkoff equations and obtain for the transition from a hot, normal quark matter core of a protoneutron star to a cool diquark condensed one a release of binding energy of the order of Delta M c^2 ~ 10^{53} erg. We find that this energy could not serve as an engine for explosive phenomena since the phase transition is not first order. Contrary to naive expectations the mass defect increases when for a given temperature we neglect the possibility of diquark condensation.Comment: 24 pages, 2 tables, 8 figures, references added, figures and text improve
    corecore