13 research outputs found

    The influence of dispersing additive on the paraffin crystallization in model systems

    Get PDF
    The work is dedicated to investigation of the influence of dispersing additive on the paraffin crystallization in model systems. A new method to determine the paraffin saturation point of transparent solutions based on the phenomenon of light scattering has been proposed. The linear relationship between the values of critical micelle concentrations of the additive and the quantity of paraffin in solution has been obtained. The influence of the model system composition on the paraffin crystallization has been studied

    Probing the Enamel Topography After Acid Erosion by Scanning Electrochemical Microscopy

    Get PDF
    In this work, we present an investigation on the thickness of the eroded enamel layer in tooth samples after exposure to citric and hydrochloric acid by using Scanning Electrochemical Microscopy (SECM). Approaching curves with typical negative feedback behavior were obtained in enamel samples for evaluation of topographic changes. In a control experiment, SECM images showed no significant difference in the current monitored during the scan, implying that enamel demineralization did not occur in mineral water medium. Topographic SECM images obtained after contact with citric and hydrochloric acid for different periods of time showed a significant increase in the current relative to a previously protected surface, indicating the structural loss of enamel. The thickness of the enamel layer eroded after contact with hydrochloric acid was significantly higher when compared to the one obtained with citric acid. Hence, our results showed that the enamel acid erosion is a relatively fast process, which is strongly dependent on parameters such as pH, time, acid strength and acid concentration.FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico)Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq

    Prefabricated resin veneer: A case report of a simplified restorative technique

    Get PDF
    Background. The aim of this study was to describe the step-by-step procedures of clinical cases using prefabricated composite resin veneers (PCRVs), manufactured with the Brilliant New Generation composite resin (Coltene, Altstätten, Switzerland). Direct composite veneers presented some drawbacks such as the difficulty of execution and color instability of the composite resin over time. The simplified application of the PCRVs has been introduced as an interesting alternative in cases of smile asymmetry, large deficient restorations and discolored teeth. In the present investigation, the PCRV technique is described completely to help the dentist during the planning and execution of treatments with the Componeer system. Conclusion The treatment with Componeer Brilliant NG yielded excellent aesthetic results. PCRV technique is simpler than direct composite veneer technique. The specific characteristics of the system can promote the results with greater aesthetic longevity. It is important to highlight that this procedure does not replace the already established veneer technique with dental ceramics. Clinical implication. PCRVs yielded excellent surface gloss. Their dimensions, based on the golden ratio, facilitates the technique and is an excellent alternative in the aesthetic restorative treatment in the anterior region

    Qualitative SEM/EDS analysis of microleakage and apical gap formation of adhesive root-filling materials

    Get PDF
    Objective: The aim of this study was to compare the correspondence between gap formation and apical microleakage in root canals filled with epoxy resin-based (AH Plus) combined or not with resinous primer or with a dimethacrylate-based root canal sealer (Epiphany). Material and Methods: Thirty-nine lower single-rooted human premolars were filled by the lateral condensation technique (LC) and immersed in a 50-wt% aqueous silver nitrate solution at 37 degrees C (24 h). After longitudinal sectioning, epoxy resin replicas were made from the tooth specimens. Both the replicas and the specimens were prepared for scanning electron microscopy (SEM). The gaps were observed in the replicas. Apical microleakage was detected in the specimens by SEM/energy dispersive spectroscopy (SEM/EDS). The data were analyzed statistically using an Ordinal Logistic Regression model and Analysis of Correspondence (alpha=0.05). Results: Epiphany presented more regions containing gaps between dentin and sealer (p<0.05). There was correspondence between the presence of gaps and microleakage (p<0.05). Microleakage was similar among the root-filling materials (p>0.05). Conclusions: The resinous primer did not improve the sealing ability of AH Plus sealer and the presence of gaps had an effect on apical microleakage for all materials.CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior)/Institutional Qualification Program (PQI) [0090/03-4]CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior)/Institutional Qualification Program (PQI

    Influence of etching time on bond strength in dentin irradiated with erbium lasers

    No full text
    The purpose of this in vitro study was to evaluate the effect of etching time on the tensile bond strength (TBS) of a conventional adhesive bonded to dentin previously irradiated with erbium:yttrium-aluminum-garnet (Er:YAG) and erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers. Buccal and lingual surfaces of 45 third molars were flattened until the dentin was exposed and randomly assigned to three groups (n = 30) according to the dentin treatment: control (not irradiated), irradiated with Er:YAG (1 W; 250 mJ; 4 Hz; 80.6 J/cm(2)) laser or Er,Cr:YSGG (4 W; 200 mJ; 20 Hz; 71.4 J/cm(2)) laser, and into three subgroups (n = 10) according to acid etching time (15 s, 30 s or 60 s) for each experimental group. After acid etching, the adhesive was applied, followed by the construction of an inverted cone of composite resin. The samples were immersed in distilled water (37A degrees C for 24 h) and subjected to TBS test [50 kilogram-force (kgf), 0.5 mm/min]. Data were analyzed by analysis of variance (ANOVA) and Tukey statistical tests (P a parts per thousand currency signaEuro parts per thousand 0.05). Control group samples presented significant higher TBS values than those of all lased groups. Both irradiated groups exhibited similar TBS values. Samples subjected to the different etching times in each experimental group presented similar TBS. Based on the conditions of this in vitro study we concluded that Er:YAG and Er,Cr:YSGG laser irradiation of the dentin weakens the bond strength of the adhesive. Moreover, increased etching time is not able to modify the bonding strength of the adhesive to irradiated dentin.FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)[97/10823-0]FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)[CEPID/CEPOF 98/14270-8

    A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity

    No full text
    Abstract: Bulk-fill composites are claimed to be restorative materials used in deep preparations and effectively photoactivated in layers up to 4 mm. The aim of the present study was to evaluate the degree of conversion, post-gel volumetric shrinkage, and cytotoxicity of six bulk-fill and two conventional composites. Degree of conversion was determined by FTIR spectroscopy; post-gel volumetric shrinkage was determined using the strain gauge method; and cytotoxicity in human fibroblasts was evaluated indirectly by the MTT assay. Data were subjected to one-way ANOVA/Tukey's test (α = 0.05). All materials, including bulk-fill and conventional composites, were classified as non-toxic, with cell viability higher than 70%. Bulk-fill composites exhibited volumetric shrinkage similar to or lower (1.4 to 0.4%) than that of conventional composites (1.7–2.1%). However, only four of the bulk-fill composites were able to sustain a homogeneous conversion at the 4-mm depth. Despite their non-toxicity and shrinkage similar to that of conventional materials, not all commercial bulk-fill materials were able to maintain a conversion as high as 80% of the superficial layer, at the 4-mm depth, indicating some failure in the bulk-fill design of some commercial brands. Therefore, the use of bulk-fill materials in dental practice is advantageous, but special attention should be given to the selection and correct use of the materials

    Influence of the base and diluent methacrylate monomers on the polymerization stress and its determinants

    No full text
    The aim of this study was to evaluate the effect of the association between bisphenol-A diglycidyl dimethacrylate (BisGMA) or its ethoxylated version (BisEMA) with diluents derived from the ethylene glycol dimethacrylate (EGDMA), with increasing number of ethylene glycol units (1: EGDMA, 2: DEGDMA, 3: TEGDMA, or 4: TETGDMA), or trimethylol propane trimethacrylate (TMPTMA) or 1,10-decanediol dimethacrylate (D3MA) on polymerization stress, volumetric shrinkage, degree of conversion, maximum rate of polymerization (Rpmax), and elastic modulus of experimental composites. BisGMA containing formulations presented lower shrinkage and stress but higher modulus and Rpmax than those containing BisEMA. TMPTMA presented the lowest stress among all diluents, as a result of lower conversion. EGDMA, DEGDMA, TEGDMA, and TETGDMA presented similar polymerization stress which was higher than the stress presented by D3MA and TMPTMA. D3MA presented similar conversion when copolymerized with both base monomers. The other diluents presented higher conversion when associated with BisEMA. EGDMA showed similar shrinkage compared with DEGDMA and higher than the other diluents. The lower conversion achieved by TMPTMA did not jeopardize its elastic modulus, similar to the other diluents. Despite the similar conversion presented by D3MA in comparison with EGDMA and DEGDMA, its lower elastic modulus may limit its use. Rather than proposing new materials, this study provides a systematic evaluation of off the shelf monomers and their effects on stress development, as highlighted by the analysis of conversion, shrinkage and modulus, to aid the optimization of commercially available materials. (c) 2011 Wiley Periodicals, Inc. J Appl Polym Sci, 2012PNPD-CAPES [02436/09-4]PNPDCAPE

    In vitro analysis of a local polymeric device as an alternative for systemic antibiotics in Dentistry

    No full text
    <div><p>Abstract The development of a biodegradable material with antimicrobial properties for local applications is required in the prevention and treatment of infectious diseases. The objective of this study was to produce blends of poly-L-lactide acid (PLLA) synthetic polymer associated with several antimicrobials, as an alternative in the prevention and treatment of infections, as well as to evaluate its cytotoxicity, release of antimicrobials and inhibit bacteria growth. Blends of PLLA added with 20% Amoxicillin, Metronidazole, Clindamycin or Azithromicyn were used to produce Films (F) or Meshs (M) by casting and electrospinning methods, respectively. Standardized discs of the films and meshs were stored in buffer solutions (pH 5 or 7.4) and aliquots were analyzed by high performance chromatography (HPLC) during 168 hours. Cytotoxicity on human gingival fibroblasts was tested after 24, 48 and 72h by MTT reaction. The antimicrobial capacity was determined against P. gingivalis and S. pyogenes. The specimens were weighed after 3 and 6 months of storage for degradation analysis. SEM was performed to control interfaces and degradation. Antimicrobials presented a continuous and exponential drug release. Analysis showed that both M and F were able to inhibit S. pyogenes and P. gingivalis growth, indicating the release of active antimicrobial agents. The products were not toxic to the fibroblasts. Amoxicillin-film showed more degradation than PLLA at both pHs (p < 0.05), whereas Azithromycin-meshes were more degraded than PLLA at pH 7.4 (p < 0.05). PLLA association with antimicrobials is biocompatible and may represent a potential tool for the local delivery of antimicrobials.</p></div
    corecore