407 research outputs found

    Parton energy loss limits and shadowing in Drell-Yan dimuon production

    Get PDF
    A precise measurement of the ratios of the Drell-Yan cross section per nucleon for an 800 GeV/c proton beam incident on Be, Fe and W targets is reported. The behavior of the Drell-Yan ratios at small target parton momentum fraction is well described by an existing fit to the shadowing observed in deep-inelastic scattering. The cross section ratios as a function of the incident parton momentum fraction set tight limits on the energy loss of quarks passing through a cold nucleus

    Measurement of Angular Distributions of Drell-Yan Dimuons in p+pp + p Interactions at 800 GeV/c

    Full text link
    We report a measurement of the angular distributions of Drell-Yan dimuons produced using an 800 GeV/c proton beam on a hydrogen target. The polar and azimuthal angular distribution parameters have been extracted over the kinematic range 4.5<mμμ<154.5 < m_{\mu \mu} < 15 GeV/c2^2 (excluding the Υ\Upsilon resonance region), 0<pT<40 < p_T < 4 GeV/c, and 0<xF<0.80 < x_F < 0.8. The p+pp+p angular distributions are similar to those of p+dp+d, and both data sets are compared with models which attribute the cos2ϕ\cos 2 \phi distribution either to the presence of the transverse-momentum-dependent Boer-Mulders structure function h1h_1^\perp or to QCD effects. The data indicate the presence of both mechanisms. The validity of the Lam-Tung relation in p+pp+p Drell-Yan is also tested.Comment: 4 pages, 3 figure

    Measurement of Angular Distributions of Drell-Yan Dimuons in p + d Interaction at 800 GeV/c

    Get PDF
    We report a measurement of the angular distributions of Drell-Yan dimuons produced using an 800 GeV/c proton beam on a deuterium target. The muon angular distributions in polar angle θ\theta and azimuthal angle ϕ\phi have been measured over the kinematic range 4.5<mμμ<154.5 < m_{\mu \mu} < 15 GeV/c2^2, 0<pT<40 < p_T < 4 GeV/c, and 0<xF<0.80 < x_F < 0.8. No significant cos2ϕ2\phi dependence is found in these proton-induced Drell-Yan data, in contrast to the situation for pion-induced Drell-Yan. The data are compared with expectations from models which attribute the cos2ϕ2\phi distribution to a QCD vacuum effect or to the presence of the transverse-momentum-dependent Boer-Mulders structure function h1h_1^\perp. Constraints on the magnitude of the sea-quark h1h_1^\perp structure functions are obtained.Comment: 4 pages, 3 figure

    dbar/ubar Asymmetry and the Origin of the Nucleon Sea

    Full text link
    The Drell-Yan cross section ratios, σ(p+d)/σ(p+p)\sigma(p+d)/\sigma(p+p), measured in Fermilab E866, have led to the first determination of dˉ(x)/uˉ(x)\bar d(x) / \bar u(x), dˉ(x)uˉ(x)\bar d(x) - \bar u(x), and the integral of dˉ(x)uˉ(x)\bar d(x) - \bar u(x) for the proton over the range 0.02x0.3450.02 \le x \le 0.345. The E866 results are compared with predictions based on parton distribution functions and various theoretical models. The relationship between the E866 results and the NMC measurement of the Gottfried integral is discussed. The agreement between the E866 results and models employing virtual mesons indicates these non-perturbative processes play an important role in the origin of the dˉ\bar d, uˉ\bar u asymmetry in the nucleon sea.Comment: 5 pages, 3 figures, ReVTe

    Measurement of the Light Antiquark Flavor Asymmetry in the Nucleon Sea

    Get PDF
    A precise measurement of the ratio of Drell-Yan yields from an 800 GeV/c proton beam incident on hydrogen and deuterium targets is reported. Over 140,000 Drell-Yan muon pairs with dimuon mass M_{mu+ mu-} >= 4.5 GeV/c^2 were recorded. From these data, the ratio of anti-down (dbar) to anti-up (ubar) quark distributions in the proton sea is determined over a wide range in Bjorken-x. A strong x dependence is observed in the ratio dbar/ubar, showing substantial enhancement of dbar with respect to ubar for x<0.2. This result is in fair agreement with recent parton distribution parameterizations of the sea. For x>0.2, the observed dbar/ubar ratio is much nearer unity than given by the parameterizations.Comment: REVTeX, to be published in Phys. Rev. Let

    Computer-Based Interventions for Problematic Alcohol Use:a Review of Systematic Reviews

    Get PDF
    PURPOSE: The aim of this review is to provide an overview of knowledge and knowledge gaps in the field of computer-based alcohol interventions by (1) collating evidence on the effectiveness of computer-based alcohol interventions in different populations and (2) exploring the impact of four specified moderators of effectiveness: therapeutic orientation, length of intervention, guidance and trial engagement.  METHODS: A review of systematic reviews of randomized trials reporting on effectiveness of computer-based alcohol interventions published between 2005 and 2015.  RESULTS: Fourteen reviews met the inclusion criteria. Across the included reviews, it was generally reported that computer-based alcohol interventions were effective in reducing alcohol consumption, with mostly small effect sizes. There were indications that longer, multisession interventions are more effective than shorter or single session interventions. Evidence on the association between therapeutic orientation of an intervention, guidance or trial engagement and reductions in alcohol consumption is limited, as the number of reviews addressing these themes is low. None of the included reviews addressed the association between therapeutic orientation, length of intervention or guidance and trial engagement.  CONCLUSIONS: This review of systematic reviews highlights the mostly positive evidence supporting computer-based alcohol interventions as well as reveals a number of knowledge gaps that could guide future research in this field

    The LUX Prototype Detector: Heat Exchanger Development

    Full text link
    The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large (>>1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.Comment: 12 pages, 9 figure

    Wing pathology of white-nose syndrome in bats suggests life-threatening disruption of physiology

    Get PDF
    White-nose syndrome (WNS) is causing unprecedented declines in several species of North American bats. The characteristic lesions of WNS are caused by the fungus Geomyces destructans, which erodes and replaces the living skin of bats while they hibernate. It is unknown how this infection kills the bats. We review here the unique physiological importance of wings to hibernating bats in relation to the damage caused by G. destructans and propose that mortality is caused by catastrophic disruption of wing-dependent physiological functions. Mechanisms of disease associated with G. destructans seem specific to hibernating bats and are most analogous to disease caused by chytrid fungus in amphibians
    corecore