23 research outputs found

    Multidimensional Measures of Physical Activity and Their Association with Gross Motor Capacity in Children and Adolescents with Cerebral Palsy.

    Get PDF
    The current lack of adapted performance metrics leads clinicians to focus on what children with cerebral palsy (CP) do in a clinical setting, despite the ongoing debate on whether capacity (what they do at best) adequately reflects performance (what they do in daily life). Our aim was to measure these children's habitual physical activity (PA) and gross motor capacity and investigate their relationship. Using five synchronized inertial measurement units (IMU) and algorithms adapted to this population, we computed 22 PA states integrating the type (e.g., sitting, walking, etc.), duration, and intensity of PA. Their temporal sequence was visualized with a PA barcode from which information about pattern complexity and the time spent in each of the six simplified PA states (PAS; considering PA type and duration, but not intensity) was extracted and compared to capacity. Results of 25 children with CP showed no strong association between motor capacity and performance, but a certain level of motor capacity seems to be a prerequisite for the achievement of higher PAS. Our multidimensional performance measurement provides a new method of PA assessment in this population, with an easy-to-understand visual output (barcode) and objective data for clinical and scientific use

    Walking Speed of Children and Adolescents With Cerebral Palsy: Laboratory Versus Daily Life.

    Get PDF
    The purpose of this pilot study was to compare walking speed, an important component of gait, in the laboratory and daily life, in young individuals with cerebral palsy (CP) and with typical development (TD), and to quantify to what extent gait observed in clinical settings compares to gait in real life. Fifteen children, adolescents and young adults with CP (6 GMFCS I, 2 GMFCS II, and 7 GMFCS III) and 14 with TD were included. They wore 4 synchronized inertial sensors on their shanks and thighs while walking at their spontaneous self-selected speed in the laboratory, and then during 2 week-days and 1 weekend day in their daily environment. Walking speed was computed from shank angular velocity signals using a validated algorithm. The median of the speed distributions in the laboratory and daily life were compared at the group and individual levels using Wilcoxon tests and Spearman's correlation coefficients. The corresponding percentile of daily life speed equivalent to the speed in the laboratory was computed and observed at the group level. Daily-life walking speed was significantly lower compared to the laboratory for the CP group (0.91 [0.58-1.23] m/s vs 1.07 [0.73-1.28] m/s, p = 0.015), but not for TD (1.29 [1.24-1.40] m/s vs 1.29 [1.20-1.40] m/s, p = 0.715). Median speeds correlated highly in CP (p < 0.001, rho = 0.89), but not in TD. In children with CP, 60% of the daily life walking activity was at a slower speed than in-laboratory (corresponding percentile = 60). On the contrary, almost 60% of the daily life activity of TD was at a faster speed than in-laboratory (corresponding percentile = 42.5). Nevertheless, highly heterogeneous behaviors were observed within both populations and within subgroups of GMFCS level. At the group level, children with CP tend to under-perform during natural walking as compared to walking in a clinical environment. The heterogeneous behaviors at the individual level indicate that real-life gait performance cannot be directly inferred from in-laboratory capacity. This emphasizes the importance of completing clinical gait analysis with data from daily life, to better understand the overall function of children with CP

    First In-Core Simultaneous Measurements of Nuclear Heating and Thermal Neutron Flux obtained with the Innovative Mobile Calorimeter CALMOS inside the OSIRIS Reactor

    No full text
    International audienceNuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g1^{-1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g1^{-1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 1014^{14} n.cm-2.s1^{-1} and nuclear heating up to 12W.g1^{-1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematiccomparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g1^{-1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power.Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented

    Ultrasonic non destructive testing based on sparse deconvolution

    No full text
    Abstract. The acoustic modality yields non destructive testing techniques of choice for indepth investigation. Given a precise model of acoustic wave propagation in materials of possibly complex structures, acoustical imaging amounts to the so-called acoustic wave inversion. A less ambitious approach consists in processing pulse-echo data (typically, A-or B-scans) to detect localised echoes with the maximum temporal (and lateral) precision. This is a resolution enhancement problem, and more precisely a sparse deconvolution problem which is naturally addressed in the inversion framework. The paper focuses on the main sparse deconvolution methods and algorithms, with a view to apply them to ultrasonic non-destructive testing

    Simultaneous Measurements of Nuclear Heating and Thermal Neutron Flux Obtained with the CALMOS-2 Measurement Device inside the OSIRIS Reactor

    No full text
    International audienceNuclear heating inside an MTR reactor needs to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. To improve the nuclear heating knowledge, an innovative calorimetric system CALMOS has been studied, manufactured and tested for the 70MWth OSIRIS reactor operated by CEA. This device is based on a mobile calorimetric probe which can be inserted in any in-core experimental location and can be moved axially from the bottom of the core to 1000mm above the core mid-plane. Analysis of obtained results and advantages brought by the first CALMOS-1 mobile equipment have been already presented. However, some difficulties appeared with this first version. A thermal limitation in the cell did not allow to monitor nuclear heating up to the 70MW nominal power, and some significant discrepancies were observed at high heating rates between results deduced from the calibration and those obtained by the zero method. Feedback based, the new CALMOS-2 calorimeter has been designed both for extending the heating range up to 13W.g-1 and improving the zero method measurement thanks to a 4-wires technique. In addition, the CALMOS-2 calorimeter has been designed as a real operational measurement system, well suited to characterize and to follow the radiation field evolution throughout the reactor cycle. To meet this requirement, a programmable system associated with a specific software allows automatic complete cell mobility in the core, the data acquisition and the measurements processing. This paper presents the analysis of results collected during the 2015 comprehensive measurement campaign carried out with the new CALMOS-2 prototype. The 4-wires technique was tested up to around a 4 W.g-1 heating level and allowed to quantify discrepancies between zero and calibration methods. Thermal neutron flux and nuclear heating measurements from CALMOS-1 and CALMOS-2 are compared. Thermal neutron flux distributions, obtained with the Self-Power Neutron Detector suited to the CALMOS-2 calorimetric cell, are compared with those obtained with current devices. Finally, this analysis tends to emphasize advantages brought by the human machine interface automation, which deeply refined the profiles definition

    Last Improvements of the CALMOS Calorimeter Dedicated to Thermal Neutron Flux and Nuclear Heating Measurements inside the OSIRIS Reactor

    Get PDF
    Nuclear heating inside an MTR reactor needs to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. To improve the nuclear heating knowledge, an innovative calorimetric system CALMOS has been studied, manufactured and tested for the 70MWth OSIRIS reactor operated by CEA. This device is based on a mobile calorimetric probe which can be inserted in any in-core experimental location and can be moved axially from the bottom of the core to 1000 mm above the core mid-plane. Obtained results and advantages brought by the first CALMOS-1 equipment have been already presented. However, some difficulties appeared with this first version. A thermal limitation in cells did not allow to monitor nuclear heating up to the 70 MW nominal power, and some significant discrepancies were observed at high heating rates between results deduced from the calibration and those obtained by the “zero method”. Taking this feedback into account, the new CALMOS-2 calorimeter has been designed both for extending the heating range up to 13W.g-1 and for improving the “zero method” measurement thanks to the implementation of a 4-wires technique. In addition, the new calorimeter has been designed as a real operational measurement system, well suited to characterize and to follow the radiation field evolution throughout the reactor cycle. To meet this requirement, a programmable system associated with a specific software allows automatic complete cell mobility in the core, the data acquisition and the measurements processing. This paper presents the analysis of results collected during the 2015 comprehensive measurement campaign. The 4-wires technique was tested up to around a 4 W.g-1 heating level and allowed to quantify discrepancies between “zero” and calibration methods. Thermal neutron flux and nuclear heating measurements from CALMOS-1 and CALMOS-2 are compared. Thermal neutron flux distributions, obtained with the Self-Power Neutron Detector suited to the CALMOS-2 calorimetric probe, are compared with those obtained with current devices. This campaign allowed to highlight advantages brought by the human machine interface automation, which deeply refined the profiles definition. Finally, the decay of the reactor residual power after shutdown could be performed after shutdown, demonstrating the ability of such type of calorimeter to follow the heating level whatever the thermohydraulic conditions, forced or natural convection regimes

    Reliability of single-day walking performance and physical activity measures using inertial sensors in children with cerebral palsy.

    No full text
    There is a lack of objective and reliable tools to measure walking performance in children with cerebral palsy (CP). To evaluate the reliability of inertial measurement units (IMUs) measuring daily life walking performance and physical activity (PA) in children with CP and healthy controls. Algorithms were developed to analyse data collected with IMUs during 2 standard school days of the same week and 1 weekend day in 15 children with CP and 14 controls. Additionally, within a clinical trial, 10 children with CP were measured twice, on the same weekday 2 to 4 weeks apart. Relative and absolute reliabilities of PA (% time walking, standing, sitting/lying) and gait parameters (e.g., velocity, cadence) were evaluated by using the intraclass correlation coefficient (ICC) and minimal detectable change (MDC <sub>95</sub> ), comparing 2 school days of the same week, a school day with a weekend day, and the same weekday 2 to 4 weeks apart. For the 15 children with CP (mean [SD] age 13.5 [3.4] years), ICCs were very high (0.70-0.98) when comparing gait parameters for 2 school days. ICCs were lower when comparing 2 school days for 14 control children (mean [SD] age 13.9 [3.0] years) and lowest when comparing a school day with a weekend day for both CP and control children. ICCs for PA were 0.90-0.91 when measuring the same weekday 2 to 4 weeks apart but were very low when comparing 2 school days of the same week or a school day with a weekend day. MDC <sub>95</sub> values were high for both groups and all comparisons but comparable with findings of in-lab studies of similar parameters. Our IMU and algorithm setup appears to be a reliable tool to measure daily life gait parameters in children with CP when repeatedly measured on 2 school days. PA was also reliably assessed but when measuring the same school day some weeks apart. However, the high MDC <sub>95</sub> values question whether the setup can be used as a responsive outcome measure of interventions
    corecore