260 research outputs found
Microelectrode arrays of diamond-insulated graphitic channels for real time detection of exocytotic events from cultured chromaffin cells and slices of adrenal glands
A microstructured graphitic 4x4 multielectrode array was embedded in a single
crystal diamond substrate (4x4 {uG-SCD MEA) for real-time monitoring of
exocytotic events from cultured chromaffin cells and adrenal slices. The
current approach relies on the development of a parallel ion beam lithographic
technique, which assures the time effective fabrication of extended arrays with
reproducible electrode dimensions. The reported device is suitable for
performing amperometric and voltammetric recordings with high sensitivity and
temporal resolution, by simultaneously acquiring data from 16 rectangularly
shaped microelectrodes (20x3.5 um^2) separated by 200 um gaps. Taking advantage
of the array geometry we addressed the following specific issues: i) detect
both the spontaneous and KCl-evoked secretion simultaneously from several
chromaffin cells directly cultured on the device surface, ii) resolve the
waveform of different subsets of exocytotic events, iii) monitoring quantal
secretory events from thin slices of the adrenal gland. The frequency of
spontaneous release was low (0.12 Hz and 0.3 Hz respectively for adrenal slices
and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl
in cultured cells. The spike amplitude as well as rise and decay time were
comparable with those measured by carbon fiber microelectrodes and allowed to
identify three different subsets of secretory events associated to "full
fusion" events, "kiss and-run" and "kiss-and-stay" exocytosis, confirming that
the device has adequate sensitivity and time resolution for real-time
recordings. The device offers the significant advantage of shortening the time
to collect data by allowing simultaneous recordings from cell populations
either in primary cell cultures or in intact tissues
All-carbon multi-electrode array for real-time in vitro measurements of oxidizable neurotransmitters
We report on the ion beam fabrication of all-carbon multi electrode arrays
(MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond
(SCD) substrates. The fabricated SCD-MEAs are systematically employed for the
in vitro simultaneous amperometric detection of the secretory activity from
populations of chromaffin cells, demonstrating a new sensing approach with
respect to standard techniques. The biochemical stability and biocompatibility
of the SCD-based device combined with the parallel recording of
multi-electrodes array allow: i) a significant time saving in data collection
during drug screening and/or pharmacological tests over a large number of
cells, ii) the possibility of comparing altered cell functionality among cell
populations, and iii) the repeatition of acquisition runs over many cycles with
a fully non-toxic and chemically robust bio-sensitive substrate.Comment: 24 pages, 5 figure
Nanodiamonds-induced effects on neuronal firing of mouse hippocampal microcircuits
Fluorescent nanodiamonds (FND) are carbon-based nanomaterials that can
efficiently incorporate optically active photoluminescent centers such as the
nitrogen-vacancy complex, thus making them promising candidates as optical
biolabels and drug-delivery agents. FNDs exhibit bright fluorescence without
photobleaching combined with high uptake rate and low cytotoxicity. Focusing on
FNDs interference with neuronal function, here we examined their effect on
cultured hippocampal neurons, monitoring the whole network development as well
as the electrophysiological properties of single neurons. We observed that FNDs
drastically decreased the frequency of inhibitory (from 1.81 Hz to 0.86 Hz) and
excitatory (from 1.61 Hz to 0.68 Hz) miniature postsynaptic currents, and
consistently reduced action potential (AP) firing frequency (by 36%), as
measured by microelectrode arrays. On the contrary, bursts synchronization was
preserved, as well as the amplitude of spontaneous inhibitory and excitatory
events. Current-clamp recordings revealed that the ratio of neurons responding
with AP trains of high-frequency (fast-spiking) versus neurons responding with
trains of low-frequency (slow-spiking) was unaltered, suggesting that FNDs
exerted a comparable action on neuronal subpopulations. At the single cell
level, rapid onset of the somatic AP ("kink") was drastically reduced in
FND-treated neurons, suggesting a reduced contribution of axonal and dendritic
components while preserving neuronal excitability.Comment: 34 pages, 9 figure
Amyloid Beta42 oligomers up-regulate the excitatory synapses by potentiating presynaptic release while impairing postsynaptic NMDA receptors
Awareness, treatment, and control of major cardiovascular risk factors in a small-scale Italian community : results of a screening campaign
Introduction: Hypertension, hypercholesterolemia, and diabetes are the main causes of cardiovascular diseases in developed countries. However, these conditions are still poorly recognized and treated.
Objective: This study aimed at estimating the prevalence, awareness, treatment, and control rates of major cardiovascular risk factors in an unselected sample of individuals of a small community located in northern Italy.
Methods: We screened 344 sequential subjects in this study. Data collection included family and clinical history, anthropometric data, blood pressure, blood glucose, and serum cholesterol values. Individual cardiovascular risk profiles were assessed by risk charts of the Progetto Cuore.
Results: Based on personal history and/or measured values, 78.2% of subjects had hypercholesterolemia (total cholesterol levels > 190 mg/dL), 61.0% had central obesity (waist circumference 65 94 cm for men and 6580 cm for women), 51.2% had arterial hypertension (blood pressure 65 140/90 mmHg), 8.1% had diabetes (blood glucose 65 126 mg/dL), 22.7% had impaired fasting glucose (blood glucose 100\u2013125 mg/dL), and 35.5% were overweight (body mass index 25\u201329 kg/m2). Alcohol drinkers and smokers accounted for 46.2% and 22.4% of subjects, respectively. Awareness of hypertension, hypercholesterolemia, and diabetes was poor, and control of these risk factors, except for diabetes, was even worse. Prevalence of high blood pressure, high serum cholesterol, overweight, and obesity significantly increased with aging. Hypercholesterolemia and obesity were significantly more common in women, while overweight and diabetes in men. In 15.4% of participants, the risk of a major cardiovascular event in the next 10 years was either high or very high.
Conclusion: In a small community in a wealthy region of Italy, the prevalence of major cardiovascular risk factors is high, while awareness, treatment, and control are poor. Such a result highlights the importance of screening campaigns as a strategy to improve early diagnosis and access to treatment, and thus effective prevention of cardiovascular diseases in the general population
Development and characterization of a diamond-insulated graphitic multi electrode array realized with ion beam lithography
The detection of quantal exocytic events from neurons and neuroendocrine cells is a challenging task in neuroscience. One of the most promising platforms for the development of a new generation of biosensors is diamond, due to its biocompatibility, transparency and chemical inertness. Moreover, the electrical properties of diamond can be turned from a perfect insulator into a conductive material (resistivity ~mΩ·cm) by exploiting the metastable nature of this allotropic form of carbon. A 16‑channels MEA (Multi Electrode Array) suitable for cell culture growing has been fabricated by means of ion implantation. A focused 1.2 MeV He+ beam was scanned on a IIa single-crystal diamond sample (4.5 × 4.5 × 0.5 mm3) to cause highly damaged sub-superficial structures that were defined with micrometric spatial resolution. After implantation, the sample was annealed. This process provides the conversion of the sub-superficial highly damaged regions to a graphitic phase embedded in a highly insulating diamond matrix. Thanks to a three-dimensional masking technique, the endpoints of the sub-superficial channels emerge in contact with the sample surface, therefore being available as sensing electrodes. Cyclic voltammetry and amperometry measurements of solutions with increasing concentrations of adrenaline were performed to characterize the biosensor sensitivity. The reported results demonstrate that this new type of biosensor is suitable for in vitro detection of catecholamine release
Fabrication of a NCD microelectrode array for amperometric detection with micrometer spatial resolution
Nanodiamond quantum sensors reveal temperature variation associated to hippocampal neurons firing
Temperature is one of the most relevant parameters for the regulation of
intracellular processes. Measuring localized subcellular temperature gradients
is fundamental for a deeper understanding of cell function, such as the genesis
of action potentials, and cell metabolism. Here, we detect for the first time
temperature variations (1{\deg}C) associated with potentiation and depletion of
neuronal firing, exploiting a nanoscale thermometer based on optically detected
magnetic resonance in nanodiamonds. Our results provide a tool for assessing
neuronal spiking activity under physiological and pathological conditions and,
conjugated with the high sensitivity of this technique (in perspective
sensitive to < 0.1{\deg}C variations), pave the way to a systematic study of
the generation of localized temperature gradients. Furthermore, they prompt
further studies explaining in detail the physiological mechanism originating
this effect.Comment: 27 pages, 5 figures, 3 table
Realization of nano-diamond fluorescent markers for in-vitro cell imaging by means of MeV proton implantation
- …