859 research outputs found

    Analytical drain‐current model of p‐ and n‐channel OTFTs for circuit simulation

    Get PDF
    Organic thin-film transistors (OTFTs) are an emerging technology for large scale circuit integration, owing the availability of both p- and n- channel devices. For the technology development and the design of circuits and digital systems, the accurate physical modeling is mandatory. In this work we propose an unified analytical model for both p- and n- type OTFTs. The model is physically based and accounts for a double exponential density of states (DOS). It is simple, symmetric and accurately describes the below-threshold, linear, and saturation regimes via a unique formulation. The model is eventually validated with the measurements of complementary OTFTs fabricated in a fullyprinted technolog

    Test of candidate light distributors for the muon (g−-2) laser calibration system

    Full text link
    The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.Comment: accepted to Nucl.Instrum.Meth.

    Computed micro-tomographic evaluation of glide pathwith nickel-titanium rotary pathFile in maxillary firstmolars curved canals

    Get PDF
    Introduction: X-ray computed micro-tomography scanning allows high-resolution 3-dimensional imaging of small objects. In this study, micro-CT scanning was used to compare the ability of manual and mechanical glide path to maintain the original root canal anatomy. Methods: Eight extracted upper first permanent molars were scanned at the TOMOLAB station at ELETTRA Synchrotron Light Laboratory in Trieste, Italy, with a microfocus cone-beam geometry system. A total of 2,400 projections on 360 degrees have been acquired at 100 kV and 80 mu A, with a focal spot size of 8 mu m. Buccal root canals of each specimen (n = 16) were randomly assigned to Path File (P) or stainless-steel K-file (K) to perform glide path at the full working length. Specimens were then microscanned at the apical level (A) and at the point of the maximum curvature level (C) for post-treatment analyses. Curvatures of root canals were classified as moderate (= 40 degrees). The ratio of diameter ratios (RDRs) and the ratio of cross-sectional areas (RAs) were assessed. For each level of analysis (A and C), 2 balanced 2-way factorial analyses of variance (P < .05) were performed to evaluate the significance of the instrument factor and of canal curvature factor as well as the interactions of the factors both with RDRs and RAs. Results: Specimens in the K group had a mean curvature of 35.4 degrees +/- 11.5 degrees; those in the P group had a curvature of 38 degrees +/- 9.9 degrees. The instrument factor (P and K) was extremely significant (P < .001) for both the RDR and RA parameters, regardless of the point of analysis. Conclusions: Micro-CT scanning confirmed that NiTi rotary Path File instruments preserve the original canal anatomy and cause less canal aberrations. (J Endod 2012;38:389-393

    AB0691 ANALYSIS OF SARS-COV-2 ANTIBODIES IN NON-COVID-19 PATIENTS: COMPARISON BETWEEN SYSTEMIC SCLEROSIS PATIENTS AND HEALTHY CONTROLS

    Get PDF
    Background:Previous study evidenced a cross-reactivity between Sars-Cov-2 antibodies and autoimmune tissue antigen involved in connective tissue diseases, as nuclear antigen (NA), extractable nuclear antigen (ENA), histone and collagen (1). No study has been published about the titer of Sars-Cov-2 antibodies in non-infected patients with autoimmune disease.Objectives:To evaluate the titer of SARS-CoV-2 antibodies in non-COVID-19 patients and compare it between systemic sclerosis (SSc) patients and healthy controls (HC).Methods:A total of 58 patients with SSc (who fulfilled ACR/EULAR 2013 SSc classification criteria) and 18 HC were enrolled. Sera of all participants were collected, and SARS-CoV-2 antibodies (IgG and IgM) were evaluated by means ELISA. In all participants swabs for SARS-CoV-2 by real-time reverse-transcriptase-polymerase-chain-reaction assay were reported negative. Demographic, clinical, and autoimmune serological characteristics of SSc patients were recorded. The normal distribution was assessed using the Shapiro–Wilk's test. Exclusion criteria was previous or actual Sars-Cov-2 infection. Comparisons between study groups of patients were evaluated by the Student's t-test or Mann – Whitney U-test as appropriate. The differences between categorial variables were assessed by Pearson chi-square or Fisher's exact test, as opportune. Statistical significance was set at p ≀ 0.05.Results:We observed significant differences between SSc patients and HC in serum levels of Sars-Cov-2 antibodies (IgG: 1,4±2,1 AU/ml vs 0,36±0,19 AU/ml respectively (p=0,001); and IgM: 2,5±3,1 AU/ml vs 0,8±0,7 AU/ml (p=0,022)). In 5 SSc patients was found titer of Sars-Cov-2 antibodies (IgG) exceeding the cut-off, but the control of swabs for SARS-CoV-2 by real-time reverse-transcriptase-polymerase-chain-reaction assay were negative. No significative differences in Sars-Cov-2 autoantibodies titer were found in subgroup of SSc patients with or without ILD or PAH, limited or diffuse skin subset, and different autoantibodies profile. Furthermore, antibodies titer was not associated with different drugs (steroid, methotrexate, mofetil-mycophenolate and bosentan) in use.Conclusion:A cross mimicking between Sars-Cov-2 antibodies and antinuclear antibodies or anti ENA could be hypothesized. Further studies are necessary to unravel the reliability of Sars-Cov-2 antibodies detection in autoimmune disease.References:[1]Vojdani, A., Vojdani, E., & Kharrazian, D. (2021). Reaction of human monoclonal antibodies to SARS-CoV-2 proteins with tissue antigens: Implications for autoimmune diseases. Frontiers in Immunology, 11, 3679Disclosure of Interests:None declare

    Msx1 and Dlx5 act independently in development of craniofacial skeleton, but converge on the regulation of Bmp signaling in palate formation.

    Get PDF

    Axions, their Relatives and Prospects for the Future

    Full text link
    The observation of a non-vanishing rotation of linear polarized laser light after passage through a strong magnetic field by the PVLAS collaboration has renewed the interest in light particles coupled to photons. Axions are a species of such particles that is theoretically well motivated. However, the relation between coupling and mass predicted by standard axion models conflicts with the PVLAS observation. Moreover, light particles with a coupling to photons of the strength required to explain PVLAS face trouble from astrophysical bounds. We discuss models that can avoid these bounds. Finally, we present some ideas to test these possible explanations of PVLAS experimentally.Comment: 11 pages, 4 figures. Contributed to the ``Third Symposium on Large TPCs for Low Energy Rare Event Detection'' in Paris, December 200
    • 

    corecore