122 research outputs found

    Revelations of Folies through Geometric Transformations

    Get PDF
    This article presents an activity carried out in a course on representation in a master’s degree in architecture, which aims to train students in the practice and theory of geometric transformation for the production of shapes, using a case study from contemporary architectural design: the Folies of the Parc de la Villette

    Between barriers and inclusion. Multidisciplinary reflections on gender and disability

    Get PDF
    The European project RISEWISE offered a possible model for a multidisciplinary collaboration. During the four years, innovative goals were pursued for breaking down barriers ranging from creating spaces for dialogue and communication, to exchanging knowledge and experience between disciplines by bringing together academics and associations

    Repeatability of quantitative individual lesion and total disease multiparametric whole-body MRI measurements in prostate cancer bone metastases.

    Get PDF
    OBJECTIVES: To assess the repeatability of quantitative multiparametric whole-body MRI (mpWB-MRI) parameters in advanced prostate cancer (APC) bone metastases. METHODS: 1.5T MRI was performed twice on the same day in 10 APC patients. MpWB-MRI-included diffusion weighted imaging (DWI) and T1-weighted gradient-echo 2-point Dixon sequences. ADC and relative fat-fraction percentage (rFF%) maps were calculated, respectively. A radiologist delineated up to 10 target bone metastases per study. Means of ADC, b900 signal intensity(SI), normalised b900 SI, rFF% and maximum diameter (MD) for each target lesion and overall parameter averages across all targets per patient were recorded. The total disease volume (tDV in ml) was manually delineated on b900 images and mean global (g)ADC was derived. Bland-Altman analyses were performed with calculation of 95% repeatability coefficients (RC). RESULTS: Seventy-three individual targets (median MD 26 mm) were included. Lesion mean ADC RC was 12.5%, mean b900 SI RC 137%, normalised mean b900 SI RC 110%, rFF% RC 3.2 and target MD RC 5.5 mm (16.3%). Patient target lesion average mean ADC RC was 6.4%, b900 SI RC 104% and normalised mean b900 SI RC 39.6%. Target average rFF% RC was 1.8, average MD RC 1.3 mm (4.8%). tDV segmentation RC was 6.4% and mean gADC RC 5.3%. CONCLUSIONS: APC bone metastases' ADC, rFF% and maximum diameter, tDV and gADC show good repeatability. ADVANCES IN KNOWLEDGE: APC bone metastases' mean ADC and rFF% measurements of single lesions and global disease volumes are repeatable, supporting their potential role as quantitative biomarkers in metastatic bone disease

    Implementation of Whole-Body MRI (MY-RADS) within the OPTIMUM/MUKnine multi-centre clinical trial for patients with myeloma.

    Get PDF
    BACKGROUND: Whole-body (WB) MRI, which includes diffusion-weighted imaging (DWI) and T1-w Dixon, permits sensitive detection of marrow disease in addition to qualitative and quantitative measurements of disease and response to treatment of bone marrow. We report on the first study to embed standardised WB-MRI within a prospective, multi-centre myeloma clinical trial (IMAGIMM trial, sub-study of OPTIMUM/MUKnine) to explore the use of WB-MRI to detect minimal residual disease after treatment. METHODS: The standardised MY-RADS WB-MRI protocol was set up on a local 1.5 T scanner. An imaging manual describing the MR protocol, quality assurance/control procedures and data transfer was produced and provided to sites. For non-identical scanners (different vendor or magnet strength), site visits from our physics team were organised to support protocol optimisation. The site qualification process included review of phantom and volunteer data acquired at each site and a teleconference to brief the multidisciplinary team. Image quality of initial patients at each site was assessed. RESULTS: WB-MRI was successfully set up at 12 UK sites involving 3 vendor systems and two field strengths. Four main protocols (1.5 T Siemens, 3 T Siemens, 1.5 T Philips and 3 T GE scanners) were generated. Scanner limitations (hardware and software) and scanning time constraint required protocol modifications for 4 sites. Nevertheless, shared methodology and imaging protocols enabled other centres to obtain images suitable for qualitative and quantitative analysis. CONCLUSIONS: Standardised WB-MRI protocols can be implemented and supported in prospective multi-centre clinical trials. Trial registration NCT03188172 clinicaltrials.gov; registration date 15th June 2017 https://clinicaltrials.gov/ct2/show/study/NCT03188172

    Geometries of Light and Shadows, from Piero della Francesca to James Turrell

    Get PDF
    This chapter addresses the problem of representing light and shadow in the artistic culture, from its uncertain beginnings, related to the studies on conical linear perspective in the Fifteenth Century, to the applications of light projection in the installations of contemporary art. Here are examined in particular two works by two artists, representing two different conceptual approaches to the perception and symbolism of light and shadow. The first is the so-called Brera Madonna by Piero della Francesca, where the image projected from a luminous radiation is employed with a narrative purpose, supporting the apparently hidden script of the painting and according to the artist\u2019s own speculations about perspective as a means to clarify the phenomenal world. The second is one of James Turrell\u2019s Dark Spaces installations, where quantum electrodynamics interpretation of light is taken into account: for Turrell, light is physical and thus can shape spaces where the visitors, or viewers, can \u201csee themselves seeing.\u201d In his body of work, perceptual deceptions are carefullyproduced by the interaction of the senses with his phenomenal staging of light and darkness, but a strong symbolic component is always present, often related to his own speculative interests. In both cases, light and shadow, through their geometries, emphasize both phenomenal and spiritual contents of the work of art, intended as a device to expand the perception and the knowledge of the viewer

    Image quality in whole-body MRI using the MY-RADS protocol in a prospective multi-centre multiple myeloma study

    Get PDF
    Background The Myeloma Response Assessment and Diagnosis System (MY-RADS) guidelines establish a standardised acquisition and analysis pipeline for whole-body MRI (WB-MRI) in patients with myeloma. This is the first study to assess image quality in a multi-centre prospective trial using MY-RADS. Methods The cohort consisted of 121 examinations acquired across ten sites with a range of prior WB-MRI experience, three scanner manufacturers and two field strengths. Image quality was evaluated qualitatively by a radiologist and quantitatively using a semi-automated pipeline to quantify common artefacts and image quality issues. The intra- and inter-rater repeatability of qualitative and quantitative scoring was also assessed. Results Qualitative radiological scoring found that the image quality was generally good, with 94% of examinations rated as good or excellent and only one examination rated as non-diagnostic. There was a significant correlation between radiological and quantitative scoring for most measures, and intra- and inter-rater repeatability were generally good. When the quality of an overall examination was low, this was often due to low quality diffusion-weighted imaging (DWI), where signal to noise ratio (SNR), anterior thoracic signal loss and brain geometric distortion were found as significant predictors of examination quality. Conclusions It is possible to successfully deliver a multi-centre WB-MRI study using the MY-RADS protocol involving scanners with a range of manufacturers, models and field strengths. Quantitative measures of image quality were developed and shown to be significantly correlated with radiological assessment. The SNR of DW images was identified as a significant factor affecting overall examination quality

    A systematic review of the literature examining the diagnostic efficacy of measurement of fractionated plasma free metanephrines in the biochemical diagnosis of pheochromocytoma

    Get PDF
    BACKGROUND: Fractionated plasma metanephrine measurements are commonly used in biochemical testing in search of pheochromocytoma. METHODS: We aimed to critically appraise the diagnostic efficacy of fractionated plasma free metanephrine measurements in detecting pheochromocytoma. Nine electronic databases, meeting abstracts, and the Science Citation Index were searched and supplemented with previously unpublished data. Methodologic and reporting quality was independently assessed by two endocrinologists using a checklist developed by the Standards for Reporting of Diagnostic Studies Accuracy Group and data were independently abstracted. RESULTS: Limitations in methodologic quality were noted in all studies. In all subjects (including those with genetic predisposition): the sensitivities for detection of pheochromocytoma were 96%–100% (95% CI ranged from 82% to 100%), whereas the specificities were 85%–100% (95% CI ranged from 78% to 100%). Statistical heterogeneity was noted upon pooling positive likelihood ratios when those with predisposition to disease were included (p < 0.001). However, upon pooling the positive or negative likelihood ratios for patients with sporadic pheochromocytoma (n = 191) or those at risk for sporadic pheochromocytoma (n = 718), no statistical heterogeneity was noted (p = 0.4). For sporadic subjects, the pooled positive likelihood ratio was 5.77 (95% CI = 4.90, 6.81) and the pooled negative likelihood ratio was 0.02 (95% CI = 0.01, 0.07). CONCLUSION: Negative plasma fractionated free metanephrine measurements are effective in ruling out pheochromocytoma. However, a positive test result only moderately increases suspicion of disease, particularly when screening for sporadic pheochromocytoma

    Microplanning with Communicative Intentions: The SPUD System

    Get PDF
    The process of microplanning in Natural Language Generation (NLG) encompasses a range of problems in which a generator must bridge underlying domain-specific representations and general linguistic representations. These problems include constructing linguistic referring expressions to identify domain objects, selecting lexical items to express domain concepts, and using complex linguistic constructions to concisely convey related domain facts. In this paper, we argue that such problems are best solved through a uniform, comprehensive, declarative process. In our approach, the generator directly explores a search space for utterances described by a linguistic grammar. At each stage of search, the generator uses a model of interpretation, which characterizes the potential links between the utterance and the domain and context, to assess its progress in conveying domain-specific representations. We further address the challenges for implementation and knowledge representation in this approach. We show how to implement this approach effectively by using the lexicalized tree-adjoining grammar formalism (LTAG) to connect structure to meaning and using modal logic programming to connect meaning to context. We articulate a detailed methodology for designing grammatical and conceptua
    corecore