342 research outputs found

    Evidence of a structural anomaly at 14 K in polymerised CsC60

    Full text link
    We report the results of a high-resolution synchrotron X-ray powder diffraction study of polymerised CsC60_{60} in the temperature range 4 to 40 K. Its crystal structure is monoclinic (space group I2/m), isostructural with RbC60_{60}. Below 14 K, a spontaneous thermal contraction is observed along both the polymer chain axis, aa and the interchain separation along [111], d1d_1. This structural anomaly could trigger the occurrence of the spin-singlet ground state, observed by NMR at the same temperature.Comment: 8 pages, 5 figures, submitte

    Critical Review of the State-of-the-Art on Lumbar Percutaneous Cement Discoplasty

    Get PDF
    Interbody fusion is the gold standard surgery to treat lumbar disc degeneration disease but can be a high-risk procedure in elderly and polymorbid patients. Percutaneous Cement Discoplasty (PCD) is a minimally invasive technique developed to treat advanced stage of disc degeneration exhibiting a vacuum phenomenon. A patient-specificstand-alone spacer is created by filling the disc with polymethylmethacrylate cement, allowing to recover the disc height and improve the patient’s conditions. As it has recently been introduced in the lumbar spine, this review aims to present a transversal state-of-the-art of the surgery from its clinical practice and outcome to biomechanical and engineering topics. The literature was searched across multiple databases using predefined keywords over no limited period of time. Papers about vertebroplasty were excluded. Among 466 identified papers, the relevant ones included twelve clinical papers reporting the variations of the surgical technique, follow-up and complications, four papers reporting biomechanical ex vivo and numerical tests, and four letters related to published clinical papers. Papers presenting the operative practice are reported, as well as follow-ups up to four years. The papers found, consistently reported that PCD significantly improved the clinical status of the patients and maintained it after two years. Spine alignment was impacted by PCD: the sacral slope was significantly reduced, and disc height increased. The foramen opening correlated to the volume of injected cement. Substitutes to the acrylic cement exhibited better osteointegration and mechanical properties closer to bone tissue. Finally, limitations and risks of the surgery are discussed as well as potential improvements such as the development of new filling materials with better mechanical properties and biological integration or the investigation of the inner disc

    Experimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation

    Get PDF
    Pathologies such as cancer metastasis and osteoporosis strongly affect the mechanical properties of the vertebral bone and increase the risk of fragility fractures. The prediction of the fracture risk with a patient-specific model, directly generated from the diagnostic images of the patient, could help the clinician in the choice of the correct therapy to follow. But before such models can be used to support any clinical decision, their credibility must be demonstrated through verification, validation, and uncertainty quantification. In this study we describe a procedure for the generation of such patient-specific finite element models and present a first validation of the kinematics of the spine segment. Quantitative computed tomography images of a cadaveric lumbar spine segment presenting vertebral metastatic lesions were used to generate the model. The applied boundary conditions replicated a specific experimental test where the spine segment was loaded in compression-flexion. Model predictions in terms of vertebral surface displacements were compared against the full-field experimental displacements measured with Digital Image Correlation. A good agreement was obtained from the local comparison between experimental data and simulation results (R2 > 0.9 and RMSE% <8%). In conclusion, this work demonstrates the possibility to apply the developed modelling pipeline to predict the displacement field of human spine segment under physiological loading conditions, which is a first fundamental step in the credibility assessment of these clinical decision-support technology

    Experimental study exploring the factors that promote rib fragility in the elderly

    Get PDF
    Rib fractures represent a common injury type due to blunt chest trauma, affecting hospital stay and mortality especially in elderly patients. Factors promoting rib fragility, however, are little investigated. The purpose of this in vitro study was to explore potential determinants of human rib fragility in the elderly. 89 ribs from 13 human donors (55\u201399&nbsp;years) were loaded in antero-posterior compression until fracture using a material testing machine, while surface strains were captured using a digital image correlation system. The effects of age, sex, bone mineral density, rib level and side, four global morphological factors (e.g. rib length), and seven rib cross-sectional morphological factors (e.g. cortical thickness, determined by \u3bcCT), on fracture load were statistically examined using Pearson correlation coefficients, Mann\u2013Whitney U test as well as Kruskal\u2013Wallis test with Dunn-Bonferroni post hoc correction. Fracture load showed significant dependencies (p &lt; 0.05) from bone mineral density, age, antero-posterior rib length, cortical thickness, bone volume/tissue volume ratio, trabecular number, trabecular separation, and both cross-sectional area moments of inertia and was significantly higher at rib levels 7 and 8 compared to level 4 (p = 0.001/0.013), whereas side had no significant effect (p = 0.989). Cortical thickness exhibited the highest correlation with fracture load (r = 0.722), followed by the high correlation of fracture load with the area moment of inertia around the longitudinal rib cross-sectional axis (r = 0.687). High correlations with maximum external rib surface strain were detected for bone volume/tissue volume ratio (r = 0.631) and trabecular number (r = 0.648), which both also showed high correlations with the minimum internal rib surface strain (r = 12 0.644/ 12 0.559). Together with rib level, the determinants cortical thickness, area moment of inertia around the longitudinal rib cross-sectional axis, as well as bone mineral density exhibited the largest effects on human rib fragility with regard to the fracture load. Sex, rib cage side, and global morphology, in contrast, did not affect rib fragility in this study. When checking elderly patients for rib fractures due to blunt chest trauma, patients with low bone mineral density and the mid-thoracic area should be carefully examined

    The Source Characteristics of Mt. Etna Magmas Erupted During the Last 60 ka

    Get PDF

    Tuning the Structure of Nylon 6,6 Electrospun Bundles to Mimic the Mechanical Performance of Tendon Fascicles

    Get PDF
    Tendon and ligament injuries are triggered by mechanical loading, but the specific mechanisms are not yet clearly identified. It is well established however, that the inflection and transition points in tendon stress-strain curves represent thresholds that may signal the onset of irreversible fibrillar sliding. This phenomenon often results in a progressive macroscopic failure of these tissues. With the aim to simulate and replace tendons, electrospinning has been demonstrated to be a suitable technology to produce nanofibers similar to the collagen fibrils in a mat form. These nanofibrous mats can be easily assembled in higher hierarchical levels to reproduce the whole tissue structure. Despite the fact that several groups have developed electrospun tendon-inspired structures, an investigation of the inflection and transition point mechanics is missing. Comparing their behavior with that of the natural counterpart is important to adequately replicate their behavior at physiological strain levels. To fill this gap, in this work fascicle-inspired electrospun nylon 6,6 bundles were produced with different collector peripheral speeds (i.e., 19.7 m s–1; 13.7 m s–1; 7.9 m s–1), obtaining different patterns of nanofibers alignment. The scanning electron microcopy revealed a fibril-inspired structure of the nanofibers with an orientation at the higher speed similar to those in tendons and ligaments (T/L). A tensile mechanical characterization was carried out showing an elastic-brittle biomimetic behavior for the higher speed bundles with a progressively more ductile behavior at slower speeds. Moreover, for each sample category the transition and the inflection points were defined to study how these points can shift with the nanofiber arrangement and to compare their values with those of tendons. The results of this study will be of extreme interest for the material scientists working in the field, to model and improve the design of their electrospun structures and scaffolds and enable building a new generation of artificial tendons and ligaments

    Epífitos vasculares predominantes em zonas ecológicas de forófitos, Santa Catarina, Brasil.

    Get PDF
    Espécies epifíticas apresentam formas, dimensões e biomassa distintas e colonizam os forófitos em regime temporário ou permanente. O presente trabalho teve como objetivo avaliar a distribuição de epífitos vasculares de biomassa visualmente dominante nas zonas ecológicas dos forófitos (fuste, copa interna e copa externa) da Floresta Ombrófila Densa de Santa Catarina. Os estudos foram realizados em 13 unidades amostrais, no interior das quais foram selecionados oito forófitos. Para a coleta dos dados, foi empregada a técnica de arvorismo e observação a partir do solo. De modo geral, as espécies registradas puderam ser classificadas como holoepífitos característicos e facultativos, e hemiepífitos primários e secundários. A família Bromeliaceae destacou-se dentre as demais nas três zonas ecológicas dos forófitos, reunindo as espécies com maiores biomassas. Relacionando as categorias ecológicas, os holoepífitos característicos, como bromeliáceas e orquidáceas, concentraram-se na região da copa e os hemiepífitos, como as aráceas Philodendron loefgrenii e Philodendron appendiculatum, foram encontradas geralmente na região do fuste.Edição especial: II Seminário sobre Inventário Florestal
    • …
    corecore