890 research outputs found
Poloidal asymmetries in edge transport barriers
Measurements of impurities in Alcator C-Mod indicate that in the pedestal region, significant poloidal asymmetries can exist in the impurity density, ion temperature, and main ion density. In light of the observation that ion temperature and electrostatic potential are not constant on a flux surface [Theiler et al., Nucl. Fusion 54, 083017 (2014)], a technique based on total pressure conservation to align profiles measured at separate poloidal locations is presented and applied. Gyrokinetic neoclassical simulations with XGCa support the observed large poloidal variations in ion temperature and density, and that the total pressure is approximately constant on a flux surface. With the updated alignment technique, the observed in-out asymmetry in impurity density is reduced from previous publishing [Churchill et al., Nucl. Fusion 53, 122002 (2013)], but remains substantial (nz,H/nz,L∼6). Candidate asymmetry drivers are explored, showing that neither non-uniform impurity sources nor localized fluctuation-driven transport are able to explain satisfactorily the impurity density asymmetry. Since impurity density asymmetries are only present in plasmas with strong electron density gradients, and radial transport timescales become comparable to parallel transport timescales in the pedestal region, it is suggested that global transport effects relating to the strong electron density gradients in the pedestal are the main driver for the pedestal in-out impurity density asymmetry.United States. Department of Energy (DE-FC02-99ER54512)United States. Department of Energy (DE-FG02-06ER54845)United States. Department of Energy (DE-FG02-86ER53223)United States. Department of Energy (DE-AC02-09CH11466
Double quantum dot with integrated charge sensor based on Ge/Si heterostructure nanowires
Coupled electron spins in semiconductor double quantum dots hold promise as
the basis for solid-state qubits. To date, most experiments have used III-V
materials, in which coherence is limited by hyperfine interactions. Ge/Si
heterostructure nanowires seem ideally suited to overcome this limitation: the
predominance of spin-zero nuclei suppresses the hyperfine interaction and
chemical synthesis creates a clean and defect-free system with highly
controllable properties. Here we present a top gate-defined double quantum dot
based on Ge/Si heterostructure nanowires with fully tunable coupling between
the dots and to the leads. We also demonstrate a novel approach to charge
sensing in a one-dimensional nanostructure by capacitively coupling the double
dot to a single dot on an adjacent nanowire. The double quantum dot and
integrated charge sensor serve as an essential building block required to form
a solid-state spin qubit free of nuclear spin.Comment: Related work at http://marcuslab.harvard.edu and
http://cmliris.harvard.ed
Electrical control over single hole spins in nanowire quantum dots
Single electron spins in semiconductor quantum dots (QDs) are a versatile
platform for quantum information processing, however controlling decoherence
remains a considerable challenge. Recently, hole spins have emerged as a
promising alternative. Holes in III-V semiconductors have unique properties,
such as strong spin-orbit interaction and weak coupling to nuclear spins, and
therefore have potential for enhanced spin control and longer coherence times.
Weaker hyperfine interaction has already been reported in self-assembled
quantum dots using quantum optics techniques. However, challenging fabrication
has so far kept the promise of hole-spin-based electronic devices out of reach
in conventional III-V heterostructures. Here, we report gate-tuneable hole
quantum dots formed in InSb nanowires. Using these devices we demonstrate Pauli
spin blockade and electrical control of single hole spins. The devices are
fully tuneable between hole and electron QDs, enabling direct comparison
between the hyperfine interaction strengths, g-factors and spin blockade
anisotropies in the two regimes
A quantum spin transducer based on nano electro-mechancial resonator arrays
Implementation of quantum information processing faces the contradicting
requirements of combining excellent isolation to avoid decoherence with the
ability to control coherent interactions in a many-body quantum system. For
example, spin degrees of freedom of electrons and nuclei provide a good quantum
memory due to their weak magnetic interactions with the environment. However,
for the same reason it is difficult to achieve controlled entanglement of spins
over distances larger than tens of nanometers. Here we propose a universal
realization of a quantum data bus for electronic spin qubits where spins are
coupled to the motion of magnetized mechanical resonators via magnetic field
gradients. Provided that the mechanical system is charged, the magnetic moments
associated with spin qubits can be effectively amplified to enable a coherent
spin-spin coupling over long distances via Coulomb forces. Our approach is
applicable to a wide class of electronic spin qubits which can be localized
near the magnetized tips and can be used for the implementation of hybrid
quantum computing architectures
The Reproducibility of a Kinematically-Derived Axis of the Knee versus Digitized Anatomical Landmarks using a Knee Navigation System
Component position is critical to longevity of knee arthroplasties. Femoral component rotation is typically referenced from the transepicondylar axis (TEA), the anterior-posterior (AP) axis or the posterior condylar axis. Other studies have shown high variability in locating the TEA while proposing digitization of other landmarks such as the AP axis as a less-variable reference. This study uses a navigation system to compare the reproducibility of computing a kinematically-derived, navigated knee axis (NKA) to digitizing the TEA and AP axis. Twelve knees from unembalmed cadavers were tested. Four arthroplasty surgeons digitized the femoral epicondyles and the AP axis direction as well as flexed and extended the knee repeatedly to allow for NKA determination. The variance of the NKA axis determined under neutral loading conditions was smaller than the variance of the TEA axis when the kinematics were measured in the closed surgical condition (P<0.001). However, varus, valgus, and internal loading of the leg increased the variability of the NKA. Distraction of the leg during knee flexion and extension preserved the low variability of the NKA. In conclusion, a kinematically-derived NKA under neutral or distraction loading is more reproducible than the TEA and AP axis determined by digitization
Elite Suppressor–Derived HIV-1 Envelope Glycoproteins Exhibit Reduced Entry Efficiency and Kinetics
Elite suppressors (ES) are a rare subset of HIV-1–infected individuals who are able to maintain HIV-1 viral loads below the limit of detection by ultra-sensitive clinical assays in the absence of antiretroviral therapy. Mechanism(s) responsible for this elite control are poorly understood but likely involve both host and viral factors. This study assesses ES plasma-derived envelope glycoprotein (env) fitness as a function of entry efficiency as a possible contributor to viral suppression. Fitness of virus entry was first evaluated using a novel inducible cell line with controlled surface expression levels of CD4 (receptor) and CCR5 (co-receptor). In the context of physiologic CCR5 and CD4 surface densities, ES envs exhibited significantly decreased entry efficiency relative to chronically infected viremic progressors. ES envs also demonstrated slow entry kinetics indicating the presence of virus with reduced entry fitness. Overall, ES env clones were less efficient at mediating entry than chronic progressor envs. Interestingly, acute infection envs exhibited an intermediate phenotypic pattern not distinctly different from ES or chronic progressor envs. These results imply that lower env fitness may be established early and may directly contribute to viral suppression in ES individuals
Optimizing Preprocessing and Analysis Pipelines for Single-Subject fMRI: 2. Interactions with ICA, PCA, Task Contrast and Inter-Subject Heterogeneity
A variety of preprocessing techniques are available to correct subject-dependant artifacts in fMRI, caused by head motion and physiological noise. Although it has been established that the chosen preprocessing steps (or “pipeline”) may significantly affect fMRI results, it is not well understood how preprocessing choices interact with other parts of the fMRI experimental design. In this study, we examine how two experimental factors interact with preprocessing: between-subject heterogeneity, and strength of task contrast. Two levels of cognitive contrast were examined in an fMRI adaptation of the Trail-Making Test, with data from young, healthy adults. The importance of standard preprocessing with motion correction, physiological noise correction, motion parameter regression and temporal detrending were examined for the two task contrasts. We also tested subspace estimation using Principal Component Analysis (PCA), and Independent Component Analysis (ICA). Results were obtained for Penalized Discriminant Analysis, and model performance quantified with reproducibility (R) and prediction metrics (P). Simulation methods were also used to test for potential biases from individual-subject optimization. Our results demonstrate that (1) individual pipeline optimization is not significantly more biased than fixed preprocessing. In addition, (2) when applying a fixed pipeline across all subjects, the task contrast significantly affects pipeline performance; in particular, the effects of PCA and ICA models vary with contrast, and are not by themselves optimal preprocessing steps. Also, (3) selecting the optimal pipeline for each subject improves within-subject (P,R) and between-subject overlap, with the weaker cognitive contrast being more sensitive to pipeline optimization. These results demonstrate that sensitivity of fMRI results is influenced not only by preprocessing choices, but also by interactions with other experimental design factors. This paper outlines a quantitative procedure to denoise data that would otherwise be discarded due to artifact; this is particularly relevant for weak signal contrasts in single-subject, small-sample and clinical datasets
Scalable quantum register based on coupled electron spins in a room temperature solid
Realization of devices based on quantum laws might lead to building
processors that outperform their classical analogues and establishing
unconditionally secure communication protocols. Solids do usually present a
serious challenge to quantum coherence. However, owing to their spin-free
lattice and low spin orbit coupling, carbon materials and particularly diamond
are suitable for hosting robust solid state quantum registers. We show that
scalable quantum logic elements can be realized by exploring long range
magnetic dipolar coupling between individually addressable single electron
spins associated with separate color centers in diamond. Strong distance
dependence of coupling was used to characterize the separation of single qubits
98 A with unprecedented accuracy (3 A) close to a crystal lattice spacing. Our
demonstration of coherent control over both electron spins, conditional
dynamics, selective readout as well as switchable interaction, opens the way
towards a room temperature solid state scalable quantum register. Since both
electron spins are optically addressable, this solid state quantum device
operating at ambient conditions provides a degree of control that is currently
available only for atomic systems.Comment: original submitted version of the manuscrip
- …