6,021 research outputs found

    Performance of Al2O3/TiC mixed ceramic inserts coated with TiAlSiN, WC/C and DLC thin solid films during hard turning of AISI 52100 steel

    Get PDF
    The present work evaluates the turning performance of alumina (Al2O3) and titanium carbide (TiC) based mixed ceramic cutting inserts with TiAlSiN, WC/C and DLC thin-film depositions during machining of AISI 52100 steel hardened to 55 ± 2 HRC hardness. Based on the generated machining forces, coefficient of friction, geometrical characteristics of the chips, and tool wear, a comparative analysis of the performance of uncoated and coated cutting tools was carried out. The machining outcomes were interpreted in relation to the adhesion strength of coating with the substrate, surface roughness and hardness of the top surface of the coatings. It was observed that the reduction of friction and machining forces accounted to lower localized strain along the shear plane leading to lower deformation of the chips. The TiAlSiN coating exhibited superior wear-resistance at the highest cutting speed when compared to DLC and WC/C coatings owing to its higher hardness and higher coating/substrate adhesion strength. However, the DLC and WC/C coatings, although softer, accounted to significant reduction of machining forces due to their self-lubricating properties.This work is sponsored by FEDER National funds FCT under the projects: SMARTLUB “Smart self-lubricant coatings with controlled release of the lubricious agent for high temperature applications.” (ref. “POCI-01-0145-FEDER-031807”), MCTool21 “Manufacturing of cutting tools for the 21st century: from nano-scale material design to numerical process simulation” (ref.: “POCI-01-0247-FEDER-045940”) and CEMMPRE ref. “UIDB/ 00285/2020”.info:eu-repo/semantics/publishedVersio

    Graph Adaptive Knowledge Transfer for Unsupervised Domain Adaptation

    Get PDF
    Unsupervised domain adaptation has caught appealing attentions as it facilitates the unlabeled target learning by borrowing existing well-established source domain knowledge. Recent practice on domain adaptation manages to extract effective features by incorporating the pseudo labels for the target domain to better solve cross-domain distribution divergences. However, existing approaches separate target label optimization and domain-invariant feature learning as different steps. To address that issue, we develop a novel Graph Adaptive Knowledge Transfer (GAKT) model to jointly optimize target labels and domain-free features in a unified framework. Specifically, semi-supervised knowledge adaptation and label propagation on target data are coupled to benefit each other, and hence the marginal and conditional disparities across different domains will be better alleviated. Experimental evaluation on two cross-domain visual datasets demonstrates the effectiveness of our designed approach on facilitating the unlabeled target task learning, compared to the state-of-the-art domain adaptation approaches

    Elevated expression of artemis in human fibroblast cells is associated with cellular radiosensitivity and increased apoptosis

    Get PDF
    Copyright @ 2012 Nature Publishing GroupThis article has been made available through the Brunel Open Access Publishing Fund.Background: The objective of this study was to determine the molecular mechanism(s) responsible for cellular radiosensitivity in two human fibroblast cell lines 84BR and 175BR derived from two cancer patients. Methods: Clonogenic assays were performed following exposure to increasing doses of gamma radiation to confirm radiosensitivity. γ-H2AX foci assays were used to determine the efficiency of DNA double strand break (DSB) repair in cells. Quantitative-PCR (Q-PCR) established the expression levels of key DNA DSB repair proteins. Imaging flow cytometry using Annexin V-FITC was used to compare artemis expression and apoptosis in cells. Results: Clonogenic cellular hypersensitivity in the 84BR and 175BR cell lines was associated with a defect in DNA DSB repair measured by the γ-H2AX foci assay. Q-PCR analysis and imaging flow cytometry revealed a two-fold overexpression of the artemis DNA repair gene which was associated with an increased level of apoptosis in the cells before and after radiation exposure. Over-expression of normal artemis protein in a normal immortalised fibroblast cell line NB1-Tert resulted in increased radiosensitivity and apoptosis. Conclusion: We conclude elevated expression of artemis is associated with higher levels of DNA DSB, radiosensitivity and elevated apoptosis in two radio-hypersensitive cell lines. These data reveal a potentially novel mechanism responsible for radiosensitivity and show that increased artemis expression in cells can result in either radiation resistance or enhanced sensitivity.This work was supported in part by The Vidal Sassoon Foundation USA. This article is made available through the Brunel Open Access Publishing Fund

    Heart rate recovery in patients with hypertrophic cardiomyopathy

    Get PDF
    Recovery in heart rate (HR) after exercise is a measure of autonomic function and a prognostic indicator in cardiovascular disease. The aim of this study was to characterize heart rate recovery (HRR) and to determine its relation to cardiac function and morphology in patients with hypertrophic cardiomyopathy (HC). We studied 18 healthy volunteers and 41 individuals with HC. All patients underwent clinical assessment and transthoracic echocardiography. Continuous beat-by-beat assessment of HR was obtained during and after cardiopulmonary exercise testing using finger plethysmography. HRR and power spectral densities were calculated on 3 minutes of continuous RR recordings. Absolute HRR was lower in patients than that in controls at 1, 2, and 3 minutes (25.7 ± 8.4 vs 35.3 ± 11.0 beats/min, p <0.001; 36.8 ± 9.4 vs 53.6 ± 13.2 beats/min, p <0.001; 41.2 ± 12.2 vs 62.1 ± 14.5 beats/min, p <0.001, respectively). HRR remained lower in patients at 2 and 3 minutes after normalization to peak HR. After normalization to the difference in HR between peak exercise and rest, HRR was significantly impaired in individuals with obstructive HC at 3 minutes compared with controls. HR at 3 minutes correlated with peak left ventricular outflow tract gradient (B 0.154 beats/min/mm Hg, confidence interval 0.010 to 0.299, p = 0.037) and remained a significant predictor of HRR after multivariable analysis. Spectral analysis showed a trend toward an increased low-frequency to high-frequency ratio in patients (p = 0.08) suggesting sympathetic predominance. In conclusion, HRR is impaired in HC and correlates with the severity of left ventricular outflow tract gradient. Prospective studies of the prognostic implications of impaired HRR in HC are warranted. © 2014 Elsevier Inc. All rights reserved

    Measurement of T1 Mapping in Patients With Cardiac Devices: Off-Resonance Error Extends Beyond Visual Artifact but Can Be Quantified and Corrected

    Get PDF
    Background: Measurement of myocardial T1 is increasingly incorporated into standard cardiovascular magnetic resonance (CMR) protocols, however accuracy may be reduced in patients with metallic cardiovascular implants. Measurement is feasible in segments free from visual artifact, but there may still be off-resonance induced error. Aim: To quantify off-resonance induced T1 error in patients with metallic cardiovascular implants, and validate a method for error correction for a conventional MOLLI pulse sequence. Methods: Twenty-four patients with cardiac implantable electronic devices (CIEDs: 46% permanent pacemakers, PPMs; 33% implantable loop recorders, ILRs; and 21% implantable cardioverter-defibrillators, ICDs); and 31 patients with aortic valve replacement (AVR) (45% metallic) were studied. Paired mid-myocardial short-axis MOLLI and single breath-hold off-resonance field maps were acquired at 1.5 T. T1 values were measured by AHA segment, and segments with visual artifact were excluded. T1 correction was applied using a published relationship between off-resonance and T1. The accuracy of the correction was assessed in 10 healthy volunteers by measuring T1 before and after external placement of an ICD generator next to the chest to generate off-resonance. Results: T1 values in healthy volunteers with an ICD were underestimated compared to without (967 ± 52 vs. 997 ± 26 ms respectively, p = 0.0001), but were similar after correction (p = 0.57, residual difference 2 ± 27 ms). Artifact was visible in 4 ± 12, 42 ± 31, and 53 ± 27% of AHA segments in patients with ILRs, PPMs, and ICDs, respectively. In segments without artifact, T1 was underestimated by 63 ms (interquartile range: 7–143) per patient. The greatest error for patients with ILRs, PPMs and ICDs were 79, 146, and 191 ms, respectively. The presence of an AVR did not generate T1 error. Conclusion: Even when there is no visual artifact, there is error in T1 in patients with CIEDs, but not AVRs. Off-resonance field map acquisition can detect error in measured T1, and a correction can be applied to quantify T1 MOLLI accurately

    Towards Quantum Repeaters with Solid-State Qubits: Spin-Photon Entanglement Generation using Self-Assembled Quantum Dots

    Full text link
    In this chapter we review the use of spins in optically-active InAs quantum dots as the key physical building block for constructing a quantum repeater, with a particular focus on recent results demonstrating entanglement between a quantum memory (electron spin qubit) and a flying qubit (polarization- or frequency-encoded photonic qubit). This is a first step towards demonstrating entanglement between distant quantum memories (realized with quantum dots), which in turn is a milestone in the roadmap for building a functional quantum repeater. We also place this experimental work in context by providing an overview of quantum repeaters, their potential uses, and the challenges in implementing them.Comment: 51 pages. Expanded version of a chapter to appear in "Engineering the Atom-Photon Interaction" (Springer-Verlag, 2015; eds. A. Predojevic and M. W. Mitchell

    Management of chest keloids

    Get PDF
    Keloid formation is one of the most challenging clinical problems in wound healing. With increasing frequency of open heart surgery, chest keloid formations are not infrequent in the clinical practice. The numerous treatment methods including surgical excision, intralesional steroid injection, radiation therapy, laser therapy, silicone gel sheeting, and pressure therapy underscore how little is understood about keloids. Keloids have a tendency to recur after surgical excision as a single treatment. Stretching tension is clearly associated with keloid generation, as keloids tend to occur on high tension sites such as chest region. The authors treated 58 chest keloid patients with surgical excision followed by intraoperative and postoperative intralesional steroid injection. Even with minor complications and recurrences, our protocol results in excellent outcomes in cases of chest keloids

    High yield synthesis of electrolyte heating assisted electrochemically exfoliated graphene for electromagnetic interference shielding applications

    Get PDF
    Herein, we demonstrate a facile one pot synthesis of graphene nanosheets by electrochemical exfoliation of graphite. In the present study, we report a significant increase in the yield of graphene by electrolyte heating assisted electrochemical exfoliation method. The obtained results of heating assisted electrochemically exfoliated graphene (utilizing H2SO4 + KOH + DW) synthesis clearly exhibit that the yield increases similar to 4.5 times i.e. from similar to 17% (room temperature) to similar to 77% (at 80 degrees C). A plausible mechanism for the enhanced yield based on lattice expansion and vibration of intercalated ions has been put forward and discussed in details. The quality of graphene was examined by Raman, XPS, FTIR, AFM, SEM, TEM/HRTEM and TGA techniques. The Raman as well as morphogenesis results confirm the quality of the graphene nanosheets. We have used this graphene as electromagnetic interference shielding material where a comparatively large quantity of graphene is required. This graphene exhibits enhanced shielding effectiveness (46 dB at 1 mm thickness of stacked graphene sheets in frequency region 12.4 to 18 GHz) as compared to conventional electromagnetic interference shielding materials, which is greater than the recommended limit (similar to 30 dB) for techno-commercial applications. Thus the present work is suggestive for future studies on enhancement of yield of high quality graphene by proposed method and the use of synthesized graphene in electromagnetic interference shielding and other possible applications
    corecore