1,044 research outputs found

    Pituitary apoplexy can mimic acute meningoencephalitis or subarachnoid haemorrhage

    Get PDF
    Pituitary apoplexy is an uncommon but life-threatening condition that is often overlooked and underdiagnosed. We report a 45-year-old man who presented to our emergency department with a sudden onset headache, acute confusion, signs of meningeal irritation and ophthalmoplegia. An initial diagnosis of acute meningoencephalitis was made, which was amended to pituitary apoplexy following thorough investigation within the emergency department

    Endocrine therapy and related issues in hormone receptor-positive early breast cancer: a roundtable discussion by the breast cancer therapy expert group (BCTEG)

    Get PDF
    Purpose: Management of breast cancer is a rapidly evolving field, and, although evidence-based guidelines are available for clinicians to provide direction on critical issues in patient care, clinicians often left to address these issues in the context of community practice situations with their patients. These include the patient’s comorbid conditions, actual versus perceived benefit of treatments, patient’s compliance as well as financial/reimbursement issues, and long-term tolerability of therapy. Methods: A meeting of global oncology experts was convened in January 2017 with the belief that there is a gap in clinical practice guidance on several fundamental issues in breast cancer care, particularly in the community setting, where oncologists may encounter multiple tumor types. The goal was to discuss some of the most important questions in this area and provide some guidance for practicing oncologists. Results: Topics addressed included risk of contralateral breast cancer recurrence in patients with estrogen receptor-positive early breast cancer who have undergone 5 years of adjuvant endocrine therapy, adverse events associated with endocrine therapy and their management, emergent data on adjuvant bisphosphonate therapy and its apparent benefit in reducing breast cancer recurrence, recent findings of extended adjuvant endocrine therapy trials, and the use of currently available genomic biomarker tests as a means of further informing treatment decisions. Conclusions: A summary of the discussion on these topics and several ‘expert opinion statements’ are provided herein in an effort to convey the collective insights of the panel as it relates to current standard practice

    Presumed small vessel disease, imaging and cognition markers in the Alzheimer's Disease Neuroimaging Initiative

    Get PDF
    MRI-derived features of presumed cerebral small vessel disease are frequently found in Alzheimer’s disease. Influences of such markers on disease-progression measures are poorly understood. We measured markers of presumed small vessel disease (white matter hyperintensity volumes; cerebral microbleeds) on baseline images of newly enrolled individuals in the Alzheimer’s Disease Neuroimaging Initiative cohort (GO and 2) and used linear mixed models to relate these to subsequent atrophy and neuropsychological score change. We also assessed heterogeneity in white matter hyperintensity positioning within biomarker abnormality sequences, driven by the data, using the Subtype and Stage Inference algorithm. This study recruited both sexes and included: controls: [n = 159, mean(SD) age = 74(6) years]; early and late mild cognitive impairment [ns = 265 and 139, respectively, mean(SD) ages =71(7) and 72(8) years, respectively]; Alzheimer’s disease [n = 103, mean(SD) age = 75(8)] and significant memory concern [n = 72, mean(SD) age = 72(6) years]. Baseline demographic and vascular risk-factor data, and longitudinal cognitive scores (Mini-Mental State Examination; logical memory; and Trails A and B) were collected. Whole-brain and hippocampal volume change metrics were calculated. White matter hyperintensity volumes were associated with greater whole-brain and hippocampal volume changes independently of cerebral microbleeds (a doubling of baseline white matter hyperintensity was associated with an increase in atrophy rate of 0.3 ml/year for brain and 0.013 ml/year for hippocampus). Cerebral microbleeds were found in 15% of individuals and the presence of a microbleed, as opposed to none, was associated with increases in atrophy rate of 1.4 ml/year for whole brain and 0.021 ml/year for hippocampus. White matter hyperintensities were predictive of greater decline in all neuropsychological scores, while cerebral microbleeds were predictive of decline in logical memory (immediate recall) and Mini-Mental State Examination scores. We identified distinct groups with specific sequences of biomarker abnormality using continuous baseline measures and brain volume change. Four clusters were found; Group 1 showed early Alzheimer’s pathology; Group 2 showed early neurodegeneration; Group 3 had early mixed Alzheimer’s and cerebrovascular pathology; Group 4 had early neuropsychological score abnormalities. White matter hyperintensity volumes becoming abnormal was a late event for Groups 1 and 4 and an early event for 2 and 3. In summary, white matter hyperintensities and microbleeds were independently associated with progressive neurodegeneration (brain atrophy rates) and cognitive decline (change in neuropsychological scores). Mechanisms involving white matter hyperintensities and progression and microbleeds and progression may be partially separate. Distinct sequences of biomarker progression were found. White matter hyperintensity development was an early event in two sequences

    Heterotic Black Horizons

    Full text link
    We show that the supersymmetric near horizon geometry of heterotic black holes is either an AdS_3 fibration over a 7-dimensional manifold which admits a G_2 structure compatible with a connection with skew-symmetric torsion, or it is a product R^{1,1} * S^8, where S^8 is a holonomy Spin(7) manifold, preserving 2 and 1 supersymmetries respectively. Moreover, we demonstrate that the AdS_3 class of heterotic horizons can preserve 4, 6 and 8 supersymmetries provided that the geometry of the base space is further restricted. Similarly R^{1,1} * S^8 horizons with extended supersymmetry are products of R^{1,1} with special holonomy manifolds. We have also found that the heterotic horizons with 8 supersymmetries are locally isometric to AdS_3 * S^3 * T^4, AdS_3 * S^3 * K_3 or R^{1,1} * T^4 * K_3, where the radii of AdS_3 and S^3 are equal and the dilaton is constant.Comment: 35 pages, latex. Minor alterations to equation (3.11) and section 4.1, the conclusions are not affecte

    Needle stick injuries among dental students: risk factors and recommendations for prevention

    Get PDF
    Aim: To evaluate the risk factors of needle stick injuries (NSIs) sustained by undergraduate dental students and nurse students at the King's College London (KCL) Dental Institute. Materials and methods: A retrospective study evaluated the incident reports relating to NSIs reported over a period of 2 years. Factors including the dental department, study year, and when the injury took place during administration of local anaesthesia (LA) and recapping conventional syringe or clearing work surface or during disposal. Results: This report showed that students are at the highest risk of NSIs at the fourth year of their 5-year BDS course. About one-third of injuries were reported among this group of students followed by year 5 students (25%). Oral surgery clinics were the major source of incident reporting when compared with other specialised dental clinics within the institute. The left hands of the students were the most frequently affected by such injuries and then the right hands of student dental nurses. The attempt of needle recapping of conventional syringes was the least reported mechanism of injuries and constituted only 15% of the total injuries and mainly occurred in third year students. The most frequent injuries among student nurses were during disposal of the needle. Conclusion: Less NSIs occur when using safety syringes. A non-recapping policy with immediate disposal of either the conventional or safety syringe systems after injection would prevent all clearance-related NSIs sustained by nurses. To avoid NSIs, education plays a vital role particularly with effective implementation of the change to safety syringes with appropriate training

    Computer simulation of breast reduction surgery

    Get PDF
    Background: Plastic surgery of the breast, particularly breast reduction, is considered difficult. It can become a challenge for a less experienced surgeon to understand exactly what to do when facing a particular type of breast and how to avoid unsatisfactory results. Methods: The goal of this study was to create a computer model of the breast that provides a basis for the simulation of breast surgery, particularly breast reduction. The reconstruction of elastic parameters is based on observations of the breast with the patient in different positions. Results: It is shown that several measurements with the patient in different positions allow one to choose the parameters of the model and determine the elastic coefficients of the breast and the skin. The geometry of the breast before and after surgery is simulated. A qualitative study of the incision parameters’ influence on the final geometry of the breast is presented. Conclusion: The developed methodology and software allow one to estimate the form of the breast after the surgery by knowing its form before surgery and taking into consideration the parameters of incision applied by the surgeon at the time of surgery. The described approach can be used for the qualitative and quantitative study of breast reduction surgery with a satisfactory result. Level of Evidence: V (This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266.
    corecore