598 research outputs found

    Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: a pilot trial comparing sealant and standard treatment

    Get PDF
    A pilot trial to compare the efficacy of two different procedures to prevent postoperative air-leak in chronic obstructive pulmonary disease (COPD) patients submitted to upper lobectomy for non-small cell lung cancer. Sixty patients with COPD and lung cancer at the upper pulmonary lobes eligible for lobectomy were enrolled and randomly assigned either to standard treatment (ST) with stapling device or to electrocautery dissection and application of a collagen patch coated with human fibrinogen and thrombin (TachoSil) (experimental treatment [ET]) for the intra-operative completion of their fused fissures. Thirty patients were enrolled in each group during a three-year period. Preoperative characteristics were similar between the two groups. Statistically significant reduction of air-leak was registered in the ET group when overall incidence of postoperative air-leak (55% vs. 96%; P=0.03), postoperative air-leak (mean 1.63+/-1.96 vs. 4.33+/-4.12 days; P=0.0018), chest-drain (mean 3.53+/-1.59 vs. 5.90+/-3.72 days; P=0.0021) and hospital stay duration (mean 5.87+/-1.07 vs. 7.50+/-3.20 days; P=0.01) were considered. The use of TachoSil to prevent postoperative air-leak after interlobar fissure completion in patients with COPD submitted to upper lobectomy seems to be safe and more effective than the ST based on stapling device application

    Optical properties of polystyrene-ZnO nanocomposite scattering layer to improve light extraction in organic light-emitting diode

    Get PDF
    In this work, experimental measurements on polystyrene-ZnO nanocomposite scattering films and on organic light-emitting device with and without the scattering layers are presented. The results are also compared with Henyey-Greenstein radiative-transfer model to narrow down the parameters that can be important in the identification of more suitable scattering layers. As a result, an increase of efficiency of about 30% has been obtained that it can be translated in 60% of outcoupled light in respect to the total generated amount

    Crystallographic evidence of theoretically novel anion- interactions

    Get PDF
    Metals in Catalysis, Biomimetics & Inorganic Material

    Surface Modification of Bioresorbable Phosphate Glasses for Controlled Protein Adsorption

    Get PDF
    The traditional silicate bioactive glasses exhibit poor thermal processability, which inhibits fiber drawing or sintering into scaffolds. The composition of the silicate glasses has been modified to enable hot processing. However, the hot forming ability is generally at the expense of bioactivity. Metaphosphate glasses, on the other hand, possess excellent thermal processability, congruent dissolution, and a tailorable degradation rate. However, due to the layer-by-layer dissolution mechanism, cells do not attach to the material surface. Furthermore, the congruent dissolution leads to a low density of OH groups forming on the glass surface, limiting the adsorption of proteins. It is well regarded that the initial step of protein adsorption is critical as the cells interact with this protein layer, rather than the biomaterial itself. In this paper, we explore the possibility of improving protein adsorption on the surface of phosphate glasses through a variety of surface treatments, such as washing the glass surface in acidic (pH 5), neutral, and basic (pH 9) buffer solutions followed or not by a treatment with (3-aminopropyl)triethoxysilane (APTS). The impact of these surface treatments on the surface chemistry (contact angle, ζ-potential) and glass structure (FTIR) was assessed. In this manuscript, we demonstrate that understanding of the material surface chemistry enables to selectively improve the adsorption of albumin and fibronectin (used as model proteins). Furthermore, in this study, well-known silicate bioactive glasses (i.e., S53P4 and 13-93) were used as controls. While surface treatments clearly improved proteins adsorption on the surface of both silicate and phosphate glasses, it is of interest to note that protein adsorption on phosphate glasses was drastically improved to reach similar protein grafting ability to the silicate bioactive glasses. Overall, this study demonstrates that the limited cell/phosphate glass biological response can easily be overcome through deep understanding and control of the glass surface chemistry

    A Grassmann integral equation

    Full text link
    The present study introduces and investigates a new type of equation which is called Grassmann integral equation in analogy to integral equations studied in real analysis. A Grassmann integral equation is an equation which involves Grassmann integrations and which is to be obeyed by an unknown function over a (finite-dimensional) Grassmann algebra G_m. A particular type of Grassmann integral equations is explicitly studied for certain low-dimensional Grassmann algebras. The choice of the equation under investigation is motivated by the effective action formalism of (lattice) quantum field theory. In a very general setting, for the Grassmann algebras G_2n, n = 2,3,4, the finite-dimensional analogues of the generating functionals of the Green functions are worked out explicitly by solving a coupled system of nonlinear matrix equations. Finally, by imposing the condition G[{\bar\Psi},{\Psi}] = G_0[{\lambda\bar\Psi}, {\lambda\Psi}] + const., 0<\lambda\in R (\bar\Psi_k, \Psi_k, k=1,...,n, are the generators of the Grassmann algebra G_2n), between the finite-dimensional analogues G_0 and G of the (``classical'') action and effective action functionals, respectively, a special Grassmann integral equation is being established and solved which also is equivalent to a coupled system of nonlinear matrix equations. If \lambda \not= 1, solutions to this Grassmann integral equation exist for n=2 (and consequently, also for any even value of n, specifically, for n=4) but not for n=3. If \lambda=1, the considered Grassmann integral equation has always a solution which corresponds to a Gaussian integral, but remarkably in the case n=4 a further solution is found which corresponds to a non-Gaussian integral. The investigation sheds light on the structures to be met for Grassmann algebras G_2n with arbitrarily chosen n.Comment: 58 pages LaTeX (v2: mainly, minor updates and corrections to the reference section; v3: references [4], [17]-[21], [39], [46], [49]-[54], [61], [64], [139] added

    Complex pleural empyema can be safely treated with vacuum-assisted closure

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>For patients with postoperative pleural empyema, open window thoracostomy (OWT) is often necessary to prevent sepsis. Vacuum-assisted closure (VAC) is a well-known therapeutic option in wound treatment. The efficacy and safety of intrathoracal VAC therapy, especially in patients with pleural empyema with bronchial stump insufficiency or remain lung, has not yet been investigated.</p> <p>Methods</p> <p>Between October 2009 and July 2010, eight consecutive patients (mean age of 66.1 years) with multimorbidity received an OWT with VAC for the treatment of postoperative or recurrent pleural empyema. Two of them had a bronchial stump insufficiency (BPF).</p> <p>Results</p> <p>VAC therapy ensured local control of the empyema and control of sepsis. The continuous suction up to 125 mm Hg cleaned the wound and thoracic cavity and supported the rapid healing. Additionally, installation of a stable vacuum was possible in the two patients with BPF. The smaller bronchus stump fistula closed spontaneously due to the VAC therapy, but the larger remained open.</p> <p>The direct contact of the VAC sponge did not create any air leak or bleeding from the lung or the mediastinal structures. The VAC therapy allowed a better re-expansion of remaining lung.</p> <p>One patient died in the late postoperative period (day 47 p.o.) of multiorgan failure. In three cases, VAC therapy was continued in an outpatient service, and in four patients, the OWT was treated with conventional wound care. After a mean time of three months, the chest wall was closed in five of seven cases. However, two patients rejected the closure of the OWT. After a follow-up at 7.7 months, neither recurrent pleural empyema nor BPF was observed.</p> <p>Conclusion</p> <p>VAC therapy was effective and safe in the treatment of complicated pleural empyema. The presence of smaller bronchial stump fistula and of residual lung tissue are not a contraindication for VAC therapy.</p

    Contrast-enhanced computed tomography assessment of aortic stenosis

    Get PDF
    Objectives Non-contrast CT aortic valve calcium scoring ignores the contribution of valvular fibrosis in aortic stenosis. We assessed aortic valve calcific and non-calcific disease using contrast-enhanced CT. Methods This was a post hoc analysis of 164 patients (median age 71 (IQR 66-77) years, 78% male) with aortic stenosis (41 mild, 89 moderate, 34 severe; 7% bicuspid) who underwent echocardiography and contrast-enhanced CT as part of imaging studies. Calcific and non-calcific (fibrosis) valve tissue volumes were quantified and indexed to annulus area, using Hounsfield unit thresholds calibrated against blood pool radiodensity. The fibrocalcific ratio assessed the relative contributions of valve fibrosis and calcification. The fibrocalcific volume (sum of indexed non-calcific and calcific volumes) was compared with aortic valve peak velocity and, in a subgroup, histology and valve weight. Results Contrast-enhanced CT calcium volumes correlated with CT calcium score (r=0.80, p<0.001) and peak aortic jet velocity (r=0.55, p<0.001). The fibrocalcific ratio decreased with increasing aortic stenosis severity (mild: 1.29 (0.98-2.38), moderate: 0.87 (1.48-1.72), severe: 0.47 (0.33-0.78), p<0.001) while the fibrocalcific volume increased (mild: 109 (75-150), moderate: 191 (117-253), severe: 274 (213-344) mm 3 /cm 2). Fibrocalcific volume correlated with ex vivo valve weight (r=0.72, p<0.001). Compared with the Agatston score, fibrocalcific volume demonstrated a better correlation with peak aortic jet velocity (r=0.59 and r=0.67, respectively), particularly in females (r=0.38 and r=0.72, respectively). Conclusions Contrast-enhanced CT assessment of aortic valve calcific and non-calcific volumes correlates with aortic stenosis severity and may be preferable to non-contrast CT when fibrosis is a significant contributor to valve obstruction

    Contrast-enhanced computed tomography assessment of aortic stenosis

    Get PDF
    Abstract Objectives Non-contrast CT aortic valve calcium scoring ignores the contribution of valvular fibrosis in aortic stenosis. We assessed aortic valve calcific and non-calcific disease using contrast-enhanced CT. Methods This was a post hoc analysis of 164 patients (median age 71 (IQR 66–77) years, 78% male) with aortic stenosis (41 mild, 89 moderate, 34 severe; 7% bicuspid) who underwent echocardiography and contrast-enhanced CT as part of imaging studies. Calcific and non-calcific (fibrosis) valve tissue volumes were quantified and indexed to annulus area, using Hounsfield unit thresholds calibrated against blood pool radiodensity. The fibrocalcific ratio assessed the relative contributions of valve fibrosis and calcification. The fibrocalcific volume (sum of indexed non-calcific and calcific volumes) was compared with aortic valve peak velocity and, in a subgroup, histology and valve weight. Results Contrast-enhanced CT calcium volumes correlated with CT calcium score (r=0.80, p<0.001) and peak aortic jet velocity (r=0.55, p<0.001). The fibrocalcific ratio decreased with increasing aortic stenosis severity (mild: 1.29 (0.98–2.38), moderate: 0.87 (1.48–1.72), severe: 0.47 (0.33–0.78), p<0.001) while the fibrocalcific volume increased (mild: 109 (75–150), moderate: 191 (117–253), severe: 274 (213–344) mm3/cm2). Fibrocalcific volume correlated with ex vivo valve weight (r=0.72, p<0.001). Compared with the Agatston score, fibrocalcific volume demonstrated a better correlation with peak aortic jet velocity (r=0.59 and r=0.67, respectively), particularly in females (r=0.38 and r=0.72, respectively). Conclusions Contrast-enhanced CT assessment of aortic valve calcific and non-calcific volumes correlates with aortic stenosis severity and may be preferable to non-contrast CT when fibrosis is a significant contributor to valve obstruction
    corecore