65,292 research outputs found

    Relative energetics of acetyl-histidine protomers with and without Zn<sup>2+</sup> and a benchmark of energy methods

    No full text
    We studied acetylhistidine (AcH), bare or microsolvated with a zinc cation by simulations in isolation. First, a global search for minima of the potential energy surface combining both, empirical and first-principles methods, is performed individually for either one of five possible protonation states. Comparing the most stable structures between tautomeric forms of negatively charged AcH shows a clear preference for conformers with the neutral imidazole ring protonated at the N-epsilon-2 atom. When adding a zinc cation to the system, the situation is reversed and N-delta-1-protonated structures are energetically more favorable. Obtained minima structures then served as basis for a benchmark study to examine the goodness of commonly applied levels of theory, i.e. force fields, semi-empirical methods, density-functional approximations (DFA), and wavefunction-based methods with respect to high-level coupled-cluster calculations, i.e. the DLPNO-CCSD(T) method. All tested force fields and semi-empirical methods show a poor performance in reproducing the energy hierarchies of conformers, in particular of systems involving the zinc cation. Meta-GGA, hybrid, double hybrid DFAs, and the MP2 method are able to describe the energetics of the reference method within chemical accuracy, i.e. with a mean absolute error of less than 1kcal/mol. Best performance is found for the double hybrid DFA B3LYP+XYG3 with a mean absolute error of 0.7 kcal/mol and a maximum error of 1.8 kcal/mol. While MP2 performs similarly as B3LYP+XYG3, computational costs, i.e. timings, are increased by a factor of 4 in comparison due to the large basis sets required for accurate results

    The Chandra X-ray view of the power sources in Cepheus A

    Full text link
    The central part of the massive star-forming region Cepheus A contains several radio sources which indicate multiple outflow phenomena, yet the driving sources of the individual outflows have not been identified. We present a high-resolution Chandra observation of this region that shows the presence of bright X-ray sources, consistent with active pre-main sequence stars, while the strong absorption hampers the detection of less luminous objects. A new source has been discovered located on the line connecting H_2 emission regions at the eastern and western parts of Cepheus A. This source could be the driving source of HH 168. We present a scenario relating the observed X-ray and radio emission.Comment: 7 pages, 6 figures, accepted for publication in A&

    Numerical Implementation of Harmonic Polylogarithms to Weight w = 8

    Full text link
    We present the FORTRAN-code HPOLY.f for the numerical calculation of harmonic polylogarithms up to w = 8 at an absolute accuracy of 4.91015\sim 4.9 \cdot 10^{-15} or better. Using algebraic and argument relations the numerical representation can be limited to the range x[0,21]x \in [0, \sqrt{2}-1]. We provide replacement files to map all harmonic polylogarithms to a basis and the usual range of arguments x],+[x \in ]-\infty,+\infty[ to the above interval analytically. We also briefly comment on a numerical implementation of real valued cyclotomic harmonic polylogarithms.Comment: 19 pages LATEX, 3 Figures, ancillary dat

    The evolution of the X-ray emission of HH 2 - Investigating heating and cooling processes

    Full text link
    Young stellar objects often drive powerful bipolar outflows which evolve on time scales of a few years. An increasing number of these outflows has been detected in X-rays implying the existence of million degree plasma almost co-spatial with the lower temperature gas observed in the optical and near-IR. The details of the heating and cooling processes of the X-ray emitting part of these so-called Herbig-Haro objects are still ambiguous, e.g., whether the cooling is dominated by expansion, radiation or thermal conduction. We present a second epoch Chandra observation of the first X-ray detected Herbig-Haro object (HH 2) and derive the proper-motion of the X-ray emitting plasma and its cooling history. We argue that the most likely explanation for the constancy of the X-ray luminosity, the alignment with the optical emission and the proper-motion is that the cooling is dominated by radiative losses leading to cooling times exceeding a decade. We explain that a strong shock caused by fast material ramming into slower gas in front of it about ten years ago can explain the X-ray emission while being compatible with the available multi-wavelength data of HH 2.Comment: 5 pages with 4 figures; accepted for publication by Astronomy and Astrophysic

    Study of leakage currents in pCVD diamonds as function of the magnetic field

    Full text link
    pCVD diamond sensors are regularly used as beam loss monitors in accelerators by measuring the ionization of the lost particles. In the past these beam loss monitors showed sudden increases in the dark leakage current without beam losses and these erratic leakage currents were found to decrease, if magnetic fields were present. Here we report on a systematic study of leakage currents inside a magnetic field. The decrease of erratic currents in a magnetic field was confirmed. On the contrary, diamonds without erratic currents showed an increase of the leakage current in a magnetic field perpendicular to the electric field for fields up to 0.6T, for higher fields it decreases. A preliminary model is introduced to explain the observations.Comment: 6 pages, 16 figures, poster at Hasselt Diamond Workshop, Mar 2009, accepted version for publicatio

    Energy-limited escape revised

    Full text link
    Gas planets in close proximity to their host stars experience photoevaporative mass loss. The energy-limited escape concept is generally used to derive estimates for the planetary mass-loss rates. Our photoionization hydrodynamics simulations of the thermospheres of hot gas planets show that the energy-limited escape concept is valid only for planets with a gravitational potential lower than log10(ΦG)<13.11 \log_\mathrm{10}\left( -\Phi_{\mathrm{G}}\right) < 13.11~erg\,g1^{-1} because in these planets the radiative energy input is efficiently used to drive the planetary wind. Massive and compact planets with log10(ΦG)13.6 \log_\mathrm{10}\left( -\Phi_{\mathrm{G}}\right) \gtrsim 13.6~erg\,g1^{-1} exhibit more tightly bound atmospheres in which the complete radiative energy input is re-emitted through hydrogen Lyα\alpha and free-free emission. These planets therefore host hydrodynamically stable thermospheres. Between these two extremes the strength of the planetary winds rapidly declines as a result of a decreasing heating efficiency. Small planets undergo enhanced evaporation because they host expanded atmospheres that expose a larger surface to the stellar irradiation. We present scaling laws for the heating efficiency and the expansion radius that depend on the gravitational potential and irradiation level of the planet. The resulting revised energy-limited escape concept can be used to derive estimates for the mass-loss rates of super-Earth-sized planets as well as massive hot Jupiters with hydrogen-dominated atmospheres.Comment: 5 pages, 5 figures, accepted for publication in A&

    Advanced dosimetry systems for the space transport and space station

    Get PDF
    Advanced dosimetry system concepts are described that will provide automated and instantaneous measurement of dose and particle spectra. Systems are proposed for measuring dose rate from cosmic radiation background to greater than 3600 rads/hr. Charged particle spectrometers, both internal and external to the spacecraft, are described for determining mixed field energy spectra and particle fluxes for both real time onboard and ground-based computer evaluation of the radiation hazard. Automated passive dosimetry systems consisting of thermoluminescent dosimeters and activation techniques are proposed for recording the dose levels for twelve or more crew members. This system will allow automatic onboard readout and data storage of the accumulated dose and can be transmitted to ground after readout or data records recovered with each crew rotation

    Experimental active and passive dosimetry systems for the NASA Skylab program

    Get PDF
    Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis
    corecore