Recommended from our members
Downstream Intensification Effects Associated with CO2 Laser Mitigation of Fused Silica
Mitigation of 351nm laser-induced damage sites on fused silica exit surfaces by selective CO{sub 2} treatment has been shown to effectively arrest the exponential growth responsible for limiting the lifetime of optics in high-fluence laser systems. However, the perturbation to the optical surface profile following the mitigation process introduces phase contrast to the beam, causing some amount of downstream intensification with the potential to damage downstream optics. Control of the laser treatment process and measurement of the associated phase modulation is essential to preventing downstream 'fratricide' in damage-mitigated optical systems. In this work we present measurements of the surface morphology, intensification patterns and damage associated with various CO{sub 2} mitigation treatments on fused silica surfaces. Specifically, two components of intensification pattern, one on-axis and another off-axis can lead to damage of downstream optics and are related to rims around the ablation pit left from the mitigation process. It is shown that control of the rim structure around the edge of typical mitigation sites is crucial in preventing damage to downstream optics
Results of applying a non-evaporative mitigation technique to laser-initiated surface damage on fused-silica
We present results from a study to determine an acceptable CO{sub 2} laser-based non-evaporative mitigation protocol for use on surface damage sites in fused-silica optics. A promising protocol is identified and evaluated on a set of surface damage sites created under ICF-type laser conditions. Mitigation protocol acceptability criteria for damage re-initiation and growth, downstream intensification, and residual stress are discussed. In previous work, we found that a power ramp at the end of the protocol effectively minimizes the residual stress (<25 MPa) left in the substrate. However, the biggest difficulty in determining an acceptable protocol was balancing between low re-initiation and problematic downstream intensification. Typical growing surface damage sites mitigated with a candidate CO{sub 2} laser-based mitigation protocol all survived 351 nm, 5 ns damage testing to fluences >12.5 J/cm{sup 2}. The downstream intensification arising from the mitigated sites is evaluated, and all but one of the sites has 100% passing downstream damage expectation values. We demonstrate, for the first time, a successful non-evaporative 10.6 {micro}m CO{sub 2} laser mitigation protocol applicable to fused-silica optics used on fusion-class lasers like the National Ignition Facility (NIF)
Recommended from our members
In-situ monitoring of surface post-processing in large aperture fused silica optics with Optical Coherence Tomography
Optical Coherence Tomography is explored as a method to image laser-damage sites located on the surface of large aperture fused silica optics during post-processing via CO{sub 2} laser ablation. The signal analysis for image acquisition was adapted to meet the sensitivity requirements for this application. A long-working distance geometry was employed to allow imaging through the opposite surface of the 5-cm thick optic. The experimental results demonstrate the potential of OCT for remote monitoring of transparent material processing applications
Novel linear analysis for a gyrotron oscillator based on a spectral approach
With the aim of gaining a better physical insight into linear regimes in gyrotrons, a new linear model was developed. This model is based on a spectral approach for solving the self-consistent system of equations describing the wave-particle interaction in the cavity of a gyrotron oscillator. Taking into account the wall-losses self-consistently and including the main system inhomogeneities in the cavity geometry and in the magnetic field, the model is appropriate to consider real system parameters. The main advantage of the spectral approach, compared with a time-dependent approach, is the possibility to describe all of the stable and unstable modes, respectively, with negative and positive growth rates. This permits to reveal the existence of a new set of eigenmodes, in addition to the usual eigenmodes issued from cold-cavity modes. The proposed model can be used for studying other instabilities such as, for instance, backward waves potentially excited in gyrotron beam tunnels
Start-up scenario studies in gyrotron oscillator using a novel linear and spectral code
A linear and spectral model has recently been developed [1], describing the self-consistent wave-particle interaction in a gyrotron oscillator. The spectral approach, compared to commonly used time-evolution approaches, has the possibility to describe all of the stable and unstable modes, respectively, with negative and positive growth rates. Moreover, this approach is numerically efficient and thus appropriate for parameter scans or start-up scenario studies. The model has been successfully benchmarked against real experiments for gyrotron cavity interaction, in particular concerning start-up scenario studies. In order to study backward-wave instabilities in smooth-wall beam ducts, the numerical model has been recently extended to include a higher order finite element discretization. The model, its numerical implementation and simulation results for high power gyrotrons as well as first results for smooth-wall beam ducts will be presented
Outer-Sphere Contributions to the Electronic Structure of Type Zero Copper Proteins
Bioinorganic canon states that active-site
thiolate coordination promotes rapid electron transfer (ET)
to and from type 1 copper proteins. In recent work, we have
found that copper ET sites in proteins also can be constructed
without thiolate ligation (called “type zero” sites). Here we
report multifrequency electron paramagnetic resonance
(EPR), magnetic circular dichroism (MCD), and nuclear
magnetic resonance (NMR) spectroscopic data together with
density functional theory (DFT) and spectroscopy-oriented
configuration interaction (SORCI) calculations for type zero Pseudomonas aeruginosa azurin variants. Wild-type (type 1) and type
zero copper centers experience virtually identical ligand fields. Moreover, O-donor covalency is enhanced in type zero centers
relative that in the C112D (type 2) protein. At the same time, N-donor covalency is reduced in a similar fashion to type 1
centers. QM/MM and SORCI calculations show that the electronic structures of type zero and type 2 are intimately linked to the
orientation and coordination mode of the carboxylate ligand, which in turn is influenced by outer-sphere hydrogen bonding
Pre-hospital management protocols and perceived difficulty in diagnosing acute heart failure
Aim To illustrate the pre-hospital management arsenals and protocols in different EMS units, and to estimate the perceived difficulty of diagnosing suspected acute heart failure (AHF) compared with other common pre-hospital conditions. Methods and results A multinational survey included 104 emergency medical service (EMS) regions from 18 countries. Diagnostic and therapeutic arsenals related to AHF management were reported for each type of EMS unit. The prevalence and contents of management protocols for common medical conditions treated pre-hospitally was collected. The perceived difficulty of diagnosing AHF and other medical conditions by emergency medical dispatchers and EMS personnel was interrogated. Ultrasound devices and point-of-care testing were available in advanced life support and helicopter EMS units in fewer than 25% of EMS regions. AHF protocols were present in 80.8% of regions. Protocols for ST-elevation myocardial infarction, chest pain, and dyspnoea were present in 95.2, 80.8, and 76.0% of EMS regions, respectively. Protocolized diagnostic actions for AHF management included 12-lead electrocardiogram (92.1% of regions), ultrasound examination (16.0%), and point-of-care testings for troponin and BNP (6.0 and 3.5%). Therapeutic actions included supplementary oxygen (93.2%), non-invasive ventilation (80.7%), intravenous furosemide, opiates, nitroglycerine (69.0, 68.6, and 57.0%), and intubation 71.5%. Diagnosing suspected AHF was considered easy to moderate by EMS personnel and moderate to difficult by emergency medical dispatchers (without significant differences between de novo and decompensated heart failure). In both settings, diagnosis of suspected AHF was considered easier than pulmonary embolism and more difficult than ST-elevation myocardial infarction, asthma, and stroke. Conclusions The prevalence of AHF protocols is rather high but the contents seem to vary. Difficulty of diagnosing suspected AHF seems to be moderate compared with other pre-hospital conditions
- …