224 research outputs found

    Packed Red Blood Cell Transfusion Associates with Acute Kidney Injury After Transcatheter Aortic Valve Replacement

    Get PDF
    Background: Acute kidney injury after cardiac surgery significantly associates with morbidity and mortality. Despite not requiring cardiopulmonary bypass, transcatheter aortic valve replacement patients have an incidence of post-procedural acute kidney injury similar to patients who undergo open surgical aortic valve replacement. Packed red blood cell transfusion has been associated with morbidity and mortality after cardiac surgery. We hypothesized that packed red blood cell transfusion independently associates with acute kidney injury after transcatheter aortic valve replacement, after accounting for other risk factors. Methods: This is a single-center retrospective cohort study of 116 patients undergoing transcatheter aortic valve replacement. Post-transcatheter aortic valve replacement acute kidney injury was defined by Kidney Disease: Improving Global Outcomes serum creatinine-based criteria. Univariate comparisons between patients with and without post-transcatheter aortic valve replacement acute kidney injury were made for clinical characteristics. Multivariable logistic regression was used to assess independent association of packed red blood cell transfusion with post-transcatheter aortic valve replacement acute kidney injury (adjusting for pre-procedural renal function and other important clinical parameters). Results: Acute kidney injury occurred in 20 (17.2%) subjects. Total number of packed red blood cells transfused independently associated with post-procedure acute kidney injury (OR = 1.67 per unit, 95% CI 1.13–2.47, P = 0.01) after adjusting for pre-procedure estimated glomerular filtration rate (OR = 0.97 per ml/min/1.73m2, 95% CI 0.94–1.00, P = 0.05), nadir hemoglobin (OR = 0.88 per g/dL increase, CI 0.61–1.27, P = 0.50), and post-procedure maximum number of concurrent inotropes and vasopressors (OR = 2.09 per inotrope or vasopressor, 95% CI 1.19–3.67, P = 0.01). Conclusion: Packed red blood cell transfusion, along with post-procedure use of inotropes and vasopressors, independently associate with acute kidney injury after transcatheter aortic valve replacement. Further studies are needed to elucidate the pathobiology underlying these associations

    Interferon-Gamma Release Assays Differentiate Between Mycobacterium avium Complex and Tuberculous Lymphadenitis in Children

    Get PDF
    OBJECTIVES: To assess the performance of interferon-gamma release assays (IGRAs) in the differential diagnosis between Mycobacterium avium complex (MAC) and tuberculosis (TB) in children affected with subacute/chronic submandibular/cervical lymphadenitis. STUDY DESIGN: Multicenter observational study comparing children with microbiologically-confirmed MAC lymphadenitis from the European NontuberculouS MycoBacterial Lymphadenitis in childrEn (ENSeMBLE) study with children with TB lymphadenitis from the Spanish Network for the Study of Pediatric TB (pTBred) database. RESULTS: Overall, 78 patients with MAC and 34 with TB lymphadenitis were included. Among MAC cases, 44/74 (59.5%) had positive tuberculin skin test (TST) results at the 5 mm cutoff, compared with 32/33 (97%) TB cases (p<0.001); at the 10 mm cutoff TST results were positive in 23/74 (31.1%) vs. 26/31 (83.9%), respectively (P < .001). IGRA results were positive in only 1/32 (3.1%) MAC cases who had undergone IGRA testing, compared with 21/23 (91.3%) TB cases (p<0.001). Agreement between TST and IGRA results was poor in MAC (23.3%;κ=0.017), but good in TB cases (95.6%;κ=0.646). IGRAs had a specificity of 96.9% (95%CI:84.3-99.8%), positive predictive value (PPV) of 95.4% (95%CI:78.2-99.8%), and negative predictive value (NPV) of 93.9% (95%CI:80.4-98.9%) for TB lymphadenitis. CONCLUSIONS: In contrast to TST, IGRAs have high specificity, NPV and PPV for TB lymphadenitis in children with subacute/chronic lymphadenopathy, and consequently can help to discriminate between TB and MAC disease. Therefore, IGRAs are useful tools in the diagnostic work-up of children with lymphadenopathy, particularly when culture- and PCR-results are negative

    Saphenofemoral arteriovenous fistula as hemodialysis access

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>An upper limb arteriovenous (AV) fistula is the access of choice for haemodialysis (HD). There have been few reports of saphenofemoral AV fistulas (SFAVF) over the last 10-20 years because of previous suggestions of poor patencies and needling difficulties. Here, we describe our clinical experience with SFAVF.</p> <p>Methods</p> <p>SFAVFs were evaluated using the following variables: immediate results, early and late complications, intraoperative and postoperative complications (up to day 30), efficiency of the fistula after the onset of needling and complications associated to its use.</p> <p>Results</p> <p>Fifty-six SFAVF fistulas were created in 48 patients. Eight patients had two fistulas: 8 patent (16%), 10 transplanted (20%), 12 deaths (24%), 1 low flow (2%) and 20 thrombosis (39%) (first two months of preparation). One patient had severe hypotension during surgery, which caused thrombosis of the fistula, which was successfully thrombectomised, four thrombosed fistulae were successfully thrombectomised and revised on the first postoperative day. After 59 months of follow-up, primary patency was 44%.</p> <p>Conclusion</p> <p>SFAVF is an adequate alternative for patients without the possibility for other access in the upper limbs, allowing efficient dialysis with good long-term patency with a low complication rate.</p

    Impact of two interventions on timeliness and data quality of an electronic disease surveillance system in a resource limited setting (Peru): a prospective evaluation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A timely detection of outbreaks through surveillance is needed in order to prevent future pandemics. However, current surveillance systems may not be prepared to accomplish this goal, especially in resource limited settings. As data quality and timeliness are attributes that improve outbreak detection capacity, we assessed the effect of two interventions on such attributes in Alerta, an electronic disease surveillance system in the Peruvian Navy.</p> <p>Methods</p> <p>40 Alerta reporting units (18 clinics and 22 ships) were included in a 12-week prospective evaluation project. After a short refresher course on the notification process, units were randomly assigned to either a phone, visit or control group. Phone group sites were called three hours before the biweekly reporting deadline if they had not sent their report. Visit group sites received supervision visits on weeks 4 & 8, but no phone calls. The control group sites were not contacted by phone or visited. Timeliness and data quality were assessed by calculating the percentage of reports sent on time and percentage of errors per total number of reports, respectively.</p> <p>Results</p> <p>Timeliness improved in the phone group from 64.6% to 84% in clinics (+19.4 [95% CI, +10.3 to +28.6]; p < 0.001) and from 46.9% to 77.3% on ships (+30.4 [95% CI, +16.9 to +43.8]; p < 0.001). Visit and control groups did not show significant changes in timeliness. Error rates decreased in the visit group from 7.1% to 2% in clinics (-5.1 [95% CI, -8.7 to -1.4]; p = 0.007), but only from 7.3% to 6.7% on ships (-0.6 [95% CI, -2.4 to +1.1]; p = 0.445). Phone and control groups did not show significant improvement in data quality.</p> <p>Conclusion</p> <p>Regular phone reminders significantly improved timeliness of reports in clinics and ships, whereas supervision visits led to improved data quality only among clinics. Further investigations are needed to establish the cost-effectiveness and optimal use of each of these strategies.</p

    A systemic framework based on Soft OR approaches to support teamwork strategy: an aviation manufacturer Brazilian company case

    Get PDF
    The paper reports on the application of a combination of Operational Research (OR) approaches to a real-world case of re-designing the strategy of a department management team, in an aircraft manufacturing organization in Brazil. We combine approaches from ‘Soft’ OR Problem Structuring Methods in a multi-methodological framework arguing that this helps to discuss, develop and implement a new departmental strategy. The proposed framework uses elements of Soft Systems Methodology; Strategic Options Development and Analysis to understand and structure the situation; Value-Focused Thinking to define the means and objectives; and Value-Focused Brainstorming to highlight the potential solutions. We conceptualize a four-phased systemic framework linking elements of the above four ‘Soft’ OR approaches and apply it to a real-world case in a department where a new team leader was appointed with the specific brief to improve the departmental strategy and its performance in general. Findings suggest that combining the approaches into a framework encourages trust and participation from stakeholders which, in practice, is translated into an improved strategy for the organization. A reflection on the multi-methodological approach is proposed. Conclusions and points for further research are suggested

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of δCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter

    A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

    Get PDF
    This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model
    corecore