105 research outputs found

    Frequency Offset Correction in a Software Defined HiperLAN/2 Demodulator using Preamble Section A

    Get PDF
    In our Software Defined Radio project we perform a feasibility study of a software defined radio for two communication standards: HiperLAN/2 and Bluetooth. In this paper the Matlab/Simulink implementation of the HiperLAN/2 demodulator for the demonstrator of the project is discussed, with special attention for the frequency offset corrector. This type of correction is necessary to prevent large bit error rates that are caused by inter-subcarrier interference. The method that is proposed in this paper uses preamble section A to estimate the frequency offset. Simulation results for an AWGN channel show that the method is capable of correcting frequency offsets up to the boundary defined in the standard [1]. It was observed that frequency offset correction using only preamble section A is sensitive to ΒΏfor exampleΒΏ synchronization errors in case real-life analog front-end signals are used

    On the design of an image compression scheme based upon a priori knowledge about imaging system and image statistics

    Get PDF
    This contribution is about the design of an image compression scheme for near loss-less image compression of a restricted class of images and a specific application. The images are digital diagnostic X-ray images of the coronary vessels of the human heart. This paper proposes a novel compression scheme with a compression ratio of 8-10 with preservation of the diagnostic image quality. Central in our approach is the amount of information a trained and highly skilled observer i.e. the cardiologist is able discern at a given exposure and thus quantum noise level. The physics of the image detection process together with the a priori knowledge of the imaging system are the basis of the image statistics. Relevant elements of the human visual system complete the stochastic characterization of imaging process whereon the compression scheme is based. 1

    Development of a dynamic myocardial perfusion phantom model for tracer kinetic measurements

    Get PDF
    BACKGROUND: Absolute myocardial perfusion imaging (MPI) is beneficial in the diagnosis and prognosis of patients with suspected or known coronary artery disease. However, validation and standardization of perfusion estimates across centers is needed to ensure safe and adequate integration into the clinical workflow. Physical myocardial perfusion models can contribute to this clinical need as these can provide ground-truth validation of perfusion estimates in a simplified, though controlled setup. This work presents the design and realization of such a myocardial perfusion phantom and highlights initial performance testing of the overall phantom setup using dynamic single photon emission computed tomography. RESULTS: Due to anatomical and (patho-)physiological representation in the 3D printed myocardial perfusion phantom, we were able to acquire 22 dynamic MPI datasets in which 99mTc-labelled tracer kinetics was measured and analyzed using clinical MPI software. After phantom setup optimization, time activity curve analysis was executed for measurements with normal myocardial perfusion settings (1.5 mL/g/min) and with settings containing a regional or global perfusion deficit (0.8 mL/g/min). In these measurements, a specific amount of activated carbon was used to adsorb radiotracer in the simulated myocardial tissue. Such mimicking of myocardial tracer uptake and retention over time satisfactorily matched patient tracer kinetics. For normal perfusion levels, the absolute mean error between computed myocardial blood flow and ground-truth flow settings ranged between 0.1 and 0.4 mL/g/min. CONCLUSION: The presented myocardial perfusion phantom is a first step toward ground-truth validation of multimodal, absolute MPI applications in the clinical setting. Its dedicated and 3D printed design enables tracer kinetic measurement, including time activity curve and potentially compartmental myocardial blood flow analysis

    n- исчислСниС – рСалистичная формализация класса ΠΏΠ΅Ρ€Π΅ΠΏΠΈΡΡ‹Π²Π°ΡŽΡ‰ΠΈΡ… систСм

    Get PDF
    ΠŸΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½ Π½ΠΎΠ²Ρ‹ΠΉ Ρ„ΠΎΡ€ΠΌΠ°Π»ΠΈΠ·ΠΌ Ρ‚ΠΈΠΏΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Π½ΠΎΠ³ΠΎ Ξ·-исчислСния Π² качСствС тСорСтичСской основы для ΠΏΠΎ-строСния ΡΠΏΠ΅Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… классов систСм программирования Π½Π° основС ΠΏΠ΅Ρ€Π΅ΠΏΠΈΡΡ‹Π²Π°ΡŽΡ‰ΠΈΡ… ΠΏΡ€Π°Π²ΠΈΠ». Π€ΠΎΡ€ΠΌΠ°-Π»ΠΈΠ·ΠΌ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅Ρ‚ упорядочСнныС Π½Π΅ΠΊΠΎΠ½Ρ„Π»ΡŽΡΠ½Ρ‚Π½Ρ‹Π΅ мноТСства ΠΏΡ€Π°Π²ΠΈΠ» пСрСписывания ΠΈ взаимодСйствиС с ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ½Ρ‹ΠΌ ΠΎΠΊΡ€ΡƒΠΆΠ΅Π½ΠΈΠ΅ΠΌ, Ρ‡Ρ‚ΠΎ позволяСт Ρ€Π°ΡΡˆΠΈΡ€ΠΈΡ‚ΡŒ возмоТности программирования динамичСских ΠΏΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠΉ

    A 3D-printed anatomical pancreas and kidney phantom for optimizing SPECT/CT reconstruction settings in beta cell imaging using 111In-exendin

    Get PDF
    Contains fulltext : 165641.pdf (publisher's version ) (Open Access)BACKGROUND: Quantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages. METHODS: 3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio. RESULTS: Phantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use. CONCLUSIONS: This work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use

    Three-dimensional reconstruction of myocardial contrast perfusion from biplane cineangiograms by means of linear programming techniques

    Get PDF
    The assessment of coronary flow reserve from the instantaneous distribution of the contrast agent within the coronary vessels and myocardial muscle at the control state and at maximal flow has been limited by the superimposition of myocardial regions of interest in the two-dimensional images. To overcome these limitations, we are in the process of developing a three-dimensional (3D) reconstruction technique to compute the contrast distribution in cross sections of the myocardial muscle from two orthogonal cineangiograms. To limit the number of feasible solutions in the 3D-reconstruction space, the 3D-geometry of the endo- and epicardial boundaries of the myocardium must be determined. For the geometric reconstruction of the epicardium, the centerlines of the left coronary arterial tree are manually or automatically traced in the biplane views. Next, the bifurcations are detected automatically and matched in these two views, allowing a 3D-representation of the coronary tree. Finally, the circumference of the left ventricular myocardium in a selected cross section can be computed from the intersection points of this cross section with the 3D coronary tree using B-splines. For the geometric reconstruction of the left ventricular cavity, we envision to apply the elliptical approximation technique using the LV boundaries defined in the two orthogonal views, or by applying more complex 3D-reconstruction techniques including densitometry. The actual 3D-reconstruction of the contrast distribution in the myocardium is based on a linear programming technique (Transportation model) using cost coefficient matrices. Such a cost coefficient matrix must contain a maximum amount of a priori information, provided by a computer generated model and updated with actual data from the angiographic views. We have only begun to solve this complex problem. However, based on our first experimental results we expect that the linear programming approach with advanced cost coefficient matrices and computed model will lead to a
    • …
    corecore