207 research outputs found

    Evidence of two-dimensional macroscopic quantum tunneling of a current-biased DC-SQUID

    Get PDF
    The escape probability out of the superconducting state of a hysteretic DC-SQUID has been measured at different values of the applied magnetic flux. At low temperature, the escape current and the width of the probability distribution are temperature independent but they depend on flux. Experimental results do not fit the usual one-dimensional (1D) Macroscopic Quantum Tunneling (MQT) law but are perfectly accounted for by the two-dimensional (2D) MQT behaviour as we propose here. Near zero flux, our data confirms the recent MQT observation in a DC-SQUID \cite{Li02}.Comment: 4 pages, 4 figures Accepted to PR

    Are violations to temporal Bell inequalities there when somebody looks?

    Get PDF
    The possibility of observing violations of temporal Bell inequalities, originally proposed by Leggett as a mean of testing the quantum mechanical delocalization of suitably chosen macroscopic bodies, is discussed by taking into account the effect of the measurement process. A general criterion quantifying this possibility is defined and shown not to be fulfilled by the various experimental configurations proposed so far to test inequalities of different forms.Comment: 7 pages, 1 eps figure, needs europhys.sty and euromacr.tex, enclosed in the .tar.gz file; accepted for publication in Europhysics Letter

    Modeling and Simulation of a Microstrip-SQUID Amplifier

    Full text link
    Using a simple lumped-circuit model, we numerically study the dependence of the voltage gain and noise on the amplifier's parameters. Linear, quasi-linear, and nonlinear regimes are studied. We have shown that the voltage gain of the amplifier cannot exceed a characteristic critical value, which decreases with the increase of the input power. We have also shown that the spectrum of the voltage gain depends significantly on the level of the Johnson noise generated by the SQUID resistors.Comment: 13 page

    Quantum effects after decoherence in a quenched phase transition

    Full text link
    We study a quantum mechanical toy model that mimics some features of a quenched phase transition. Both by virtue of a time-dependent Hamiltonian or by changing the temperature of the bath we are able to show that even after classicalization has been reached, the system may display quantum behaviour again. We explain this behaviour in terms of simple non-linear analysis and estimate relevant time scales that match the results of numerical simulations of the master-equation. This opens new possibilities both in the study of quantum effects in non-equilibrium phase transitions and in general time-dependent problems where quantum effects may be relevant even after decoherence has been completed.Comment: 7 pages, 7 figures, revtex, important revisions made. To be published in Phys. Rev.

    Self-aligned nanoscale SQUID on a tip

    Get PDF
    A nanometer-sized superconducting quantum interference device (nanoSQUID) is fabricated on the apex of a sharp quartz tip and integrated into a scanning SQUID microscope. A simple self-aligned fabrication method results in nanoSQUIDs with diameters down to 100 nm with no lithographic processing. An aluminum nanoSQUID with an effective area of 0.034 μ\mum2^2 displays flux sensitivity of 1.8106\cdot 10^{-6} Φ0/Hz1/2andoperatesinfieldsashighas0.6T.Withprojectedspinsensitivityof65\Phi_0/\mathrm{Hz}^{1/2} and operates in fields as high as 0.6 T. With projected spin sensitivity of 65 \mu_B/\mathrm{Hz}^{1/2}$ and high bandwidth, the SQUID on a tip is a highly promising probe for nanoscale magnetic imaging and spectroscopy.Comment: 14 manuscript pages, 5 figure

    Continuous weak measurement of quantum coherent oscillations

    Full text link
    We consider the problem of continuous quantum measurement of coherent oscillations between two quantum states of an individual two-state system. It is shown that the interplay between the information acquisition and the backaction dephasing of the oscillations by the detector imposes a fundamental limit, equal to 4, on the signal-to-noise ratio of the measurement. The limit is universal, e.g., independent of the coupling strength between the detector and system, and results from the tendency of quantum measurement to localize the system in one of the measured eigenstates

    Optimal Monitoring of Position in Nonlinear Quantum Systems

    Get PDF
    We discuss a model of repeated measurements of position in a quantum system which is monitored for a finite amount of time with a finite instrumental error. In this framework we recover the optimum monitoring of a harmonic oscillator proposed in the case of an instantaneous collapse of the wavefunction into an infinite-accuracy measurement result. We also establish numerically the existence of an optimal measurement strategy in the case of a nonlinear system. This optimal strategy is completely defined by the spectral properties of the nonlinear system.Comment: 4 pages, REVTeX 3.0, 4 PostScript figure

    Quantum behavior of the dc SQUID phase qubit

    Full text link
    We analyze the behavior of a dc Superconducting Quantum Interference Device (SQUID) phase qubit in which one junction acts as a phase qubit and the rest of the device provides isolation from dissipation and noise in the bias leads. Ignoring dissipation, we find the two-dimensional Hamiltonian of the system and use numerical methods and a cubic approximation to solve Schrodinger's equation for the eigenstates, energy levels, tunneling rates, and expectation value of the currents in the junctions. Using these results, we investigate how well this design provides isolation while preserving the characteristics of a phase qubit. In addition, we show that the expectation value of current flowing through the isolation junction depends on the state of the qubit and can be used for non-destructive read out of the qubit state.Comment: 38 pages, 7 figure

    Airborne observations of the Eyjafjalla volcano ash cloud over Europe during air space closure in April and May 2010

    Get PDF
    © Author(s) 2011. This work is distributed under the Creative Commons Attribution 3.0 LicenseAirborne lidar and in-situ measurements of aerosols and trace gases were performed in volcanic ash plumes over Europe between Southern Germany and Iceland with the Falcon aircraft during the eruption period of the Eyjafjalla1 volcano between 19 April and 18 May 2010. Flight planning and measurement analyses were supported by a refined Meteosat ash product and trajectory model analysis. The volcanic ash plume was observed with lidar directly over the volcano and up to a distance of 2700 km downwind, and up to 120 h plume ages. Aged ash layers were between a few 100 m to 3 km deep, occurred between 1 and 7 km altitude, and were typically 100 to 300 km wide. Particles collected by impactors had diameters up to 20 μm diameter, with size and age dependent composition. Ash mass concentrations were derived from optical particle spectrometers for a particle density of 2.6 g cm-3 and various values of the refractive index (RI, real part: 1.59; 3 values for the imaginary part: 0, 0.004 and 0.008). The mass concentrations, effective diameters and related optical properties were compared with ground-based lidar observations. Theoretical considerations of particle sedimentation constrain the particle diameters to those obtained for the lower RI values. The ash mass concentration results have an uncertainty of a factor of two. The maximum ash mass concentration encountered during the 17 flights with 34 ash plume penetrations was below 1 mg m-3. The Falcon flew in ash clouds up to about 0.8 mg m-3 for a few minutes and in an ash cloud with approximately 0.2 mg -3 mean-concentration for about one hour without engine damage. The ash plumes were rather dry and correlated with considerable CO and SO2 increases and O3 decreases. To first order, ash concentration and SO2 mixing ratio in the plumes decreased by a factor of two within less than a day. In fresh plumes, the SO2 and CO concentration increases were correlated with the ash mass concentration. The ash plumes were often visible slantwise as faint dark layers, even for concentrations below 0.1 mg m-3. The large abundance of volatile Aitken mode particles suggests previous nucleation of sulfuric acid droplets. The effective diameters range between 0.2 and 3 μm with considerable surface and volume contributions from the Aitken and coarse mode aerosol, respectively. The distal ash mass flux on 2 May was of the order of 500 (240-1600) kgs -1. The volcano induced about 10 (2.5-50) Tg of distal ash mass and about 3 (0.6-23) Tg of SO2 during the whole eruption period. The results of the Falcon flights were used to support the responsible agencies in their decisions concerning air traffic in the presence of volcanic ash.Peer reviewe
    corecore