46 research outputs found
Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators
We present new results from our test of Lorentz invariance, which compares
two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We
have now acquired over 1 year of data, allowing us to avoid the short data set
approximation (less than 1 year) that assumes no cancelation occurs between the
and parameters from the photon
sector of the standard model extension. Thus, we are able to place independent
limits on all eight and parameters.
Our results represents up to a factor of 10 improvement over previous non
rotating measurements (which independently constrained 7 parameters), and is a
slight improvement (except for ) over results from
previous rotating experiments that assumed the short data set approximation.
Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a
new limit on the isotropy parameter of
, an improvement of a factor of 2.Comment: Accepted for publication in Phys. Rev.
Cryogenic sapphire oscillator with exceptionally high long-term frequency stability
We report on the development of a sapphire cryogenic microwave resonator
oscillator long-term fractional frequency stability of 2x10^-17Sqrt[\tau] for
integration times \tau>10^3 s and negative drift of about 2.2x10^-15/day. The
short-term frequency instability of the oscillator is highly reproducible and
also state-of-the-art: 5.6x10^-16 for an integration time of \tau ~ 20 s.Comment: Accepted for publication in Applied Physics Letter
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
We present the first results from a rotating Michelson-Morley experiment that
uses two orthogonally orientated cryogenic sapphire resonator-oscillators
operating in whispering gallery modes near 10 GHz. The experiment is used to
test for violations of Lorentz Invariance in the frame-work of the photon
sector of the Standard Model Extension (SME), as well as the isotropy term of
the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on
the previously unmeasured component of
, and set more stringent bounds by up to a factor of 7
on seven other components. In the RMS a more stringent bound of
on the isotropy parameter, is set, which is more than a factor of 7 improvement. More detailed
description of the experiment and calculations can be found in: hep-ph/0506200Comment: Final published version, 4 pages, references adde
Relativity tests by complementary rotating Michelson-Morley experiments
We report Relativity tests based on data from two simultaneous
Michelson-Morley experiments, spanning a period of more than one year. Both
were actively rotated on turntables. One (in Berlin, Germany) uses optical
Fabry-Perot resonators made of fused silica; the other (in Perth, Australia)
uses microwave whispering-gallery sapphire resonators. Within the standard
model extension, we obtain simultaneous limits on Lorentz violation for
electrons (5 coefficients) and photons (8) at levels down to ,
improved by factors between 3 and 50 compared to previous work.Comment: 5 pages revtex, 2 figure
Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics
In this work we outline the two most commonly used test theories (RMS and
SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop
the general framework of applying these test theories to resonator experiments
with an emphasis on rotating experiments in the laboratory. We compare the
inherent sensitivity factors of common experiments and propose some new
configurations. Finally we apply the test theories to the rotating cryogenic
experiment at the University of Western Australia, which recently set new
limits in both the RMS and SME frameworks [hep-ph/0506074].Comment: Submitted to Lecture Notes in Physics, 36 pages, minor modifications,
updated list of reference
Far-field optical imaging and manipulation of individual spins with nanoscale resolution
A fundamental limit to existing optical techniques for measurementand manipulation of spin degrees of freedom is set by diffraction, which does not allow spins separated by less than about a quarter of a micrometre to be resolved using conventional far-field optics. Here, we report an efficient far-field optical technique that overcomes the limiting role of diffraction, allowing individual electronic spins to be detected, imaged and manipulated coherently with nanoscale resolution. The technique involves selective flipping of the orientation of individual spins, associated with nitrogen-vacancy centres in room-temperature diamond, using a focused beam of light with intensity vanishing at a controllable location, which enables simultaneous single-spin imaging and magnetometry at the nanoscale with considerably less power than conventional techniques. Furthermore, by inhibiting spin transitions away from the laser intensity null, selective coherent rotation of individual spins is realized. This technique can be extended to subnanometre dimensions, thus enabling applications in diverse areas ranging from quantum information science to bioimaging
Fourier Magnetic Imaging with Nanoscale Resolution and Compressed Sensing Speed-up using Electronic Spins in Diamond
Optically-detected magnetic resonance using Nitrogen Vacancy (NV) color
centres in diamond is a leading modality for nanoscale magnetic field imaging,
as it provides single electron spin sensitivity, three-dimensional resolution
better than 1 nm, and applicability to a wide range of physical and biological
samples under ambient conditions. To date, however, NV-diamond magnetic imaging
has been performed using real space techniques, which are either limited by
optical diffraction to 250 nm resolution or require slow, point-by-point
scanning for nanoscale resolution, e.g., using an atomic force microscope,
magnetic tip, or super-resolution optical imaging. Here we introduce an
alternative technique of Fourier magnetic imaging using NV-diamond. In analogy
with conventional magnetic resonance imaging (MRI), we employ pulsed magnetic
field gradients to phase-encode spatial information on NV electronic spins in
wavenumber or k-space followed by a fast Fourier transform to yield real-space
images with nanoscale resolution, wide field-of-view (FOV), and compressed
sensing speed-up.Comment: 31 pages, 10 figure
Points to consider in cardiovascular disease risk management among patients with rheumatoid arthritis living in South Africa, an unequal middle income country
Background: It is plausible that optimal cardiovascular disease (CVD) risk management differs in patients with rheumatoid arthritis (RA) from low or middle income compared to high income populations. This study aimed at producing evidence-based points to consider for CVD prevention in South African RA patients. Methods: Five rheumatologists, one cardiologist and one epidemiologist with experience in CVD risk management in RA patients, as well as two patient representatives, two health professionals and one radiologist, one rheumatology fellow and 11 rheumatologists that treat RA patients regularly contributed. Systematic literature searches were performed and the level of evidence was determined according to standard guidelines. Results: Eighteen points to consider were formulated. These were grouped into 6 categories that comprised overall CVD risk assessment and management (n = 4), and specific interventions aimed at reducing CVD risk including RA control with disease modifying anti-rheumatic drugs, glucocorticoids and non-steroidal anti-inflammatory drugs (n = 3), lipid lowering agents (n = 8), antihypertensive drugs (n = 1), low dose aspirin (n = 1) and lifestyle modification (n = 1). Each point to consider differs partially or completely from recommendations previously reported for CVD risk management in RA patients from high income populations. Currently recommended CVD risk calculators do not reliably identify South African black RA patients with very high-risk atherosclerosis as represented by carotid artery plaque presence on ultrasound. Conclusions: Our findings indicate that optimal cardiovascular risk management likely differs substantially in RA patients from low or middle income compared to high income populations. There is an urgent need for future multicentre longitudinal studies on CVD risk in black African patients with RA
A Review of One-Way and Two-Way Experiments to Test the Isotropy of the Speed of Light
As we approach the 125th anniversary of the Michelson-Morley experiment in
2012, we review experiments that test the isotropy of the speed of light.
Previous measurements are categorized into one-way (single-trip) and two-way
(round-trip averaged or over closed paths) approaches and the level of
experimental verification that these experiments provide is discussed. The
isotropy of the speed of light is one of the postulates of the Special Theory
of Relativity (STR) and, consequently, this phenomenon has been subject to
considerable experimental scrutiny. Here, we tabulate significant experiments
performed since 1881 and attempt to indicate a direction for future
investigation.Comment: Updated Fig. 7 and references; Revised sections 3.2 and 4. Accepted
in the Indian Journal of Physics on March 30, 201