515 research outputs found

    New pixelized Micromegas detector with low discharge rate for the COMPASS experiment

    Full text link
    New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micromegas detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Two solutions of reduction of discharge impact have been studied, with Micromegas detectors using resistive layers and using an additional GEM foil. Performance of such detectors has also been measured. A large size prototypes with nominal active area and pixelized read-out has been produced and installed at COMPASS in 2010. In 2011 prototypes featuring an additional GEM foil, as well as an resistive prototype, are installed at COMPASS and preliminary results from those detectors presented very good performance. We present here the project and report on its status, in particular the performance of large size prototypes with an additional GEM foil.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japa

    Neutrinos in a spherical box

    Full text link
    In the present paper we study some neutrino properties as they may appear in the low energy neutrinos emitted in triton decay with maximum neutrino energy of 18.6 keV. The technical challenges to this end can be achieved by building a very large TPC capable of detecting low energy recoils, down to a a few tenths of a keV, within the required low background constraints. More specifically We propose the development of a spherical gaseous TPC of about 10-m in radius and a 200 Mcurie triton source in the center of curvature. One can list a number of exciting studies, concerning fundamental physics issues, that could be made using a large volume TPC and low energy antineutrinos: 1) The oscillation length involving the small angle of the neutrino mixing matrix, directly measured in this disappearance experiment, is fully contained inside the detector. Measuring the counting rate of neutrino-electron elastic scattering as a function of the distance of the source will give a precise and unambiguous measurement of the oscillation parameters free of systematic errors. In fact first estimates show that even with a year's data taking a sensitivity of a few percent for the measurement of the above angle will be achieved. 2) The low energy detection threshold offers a unique sensitivity for the neutrino magnetic moment which is about two orders of magnitude beyond the current experimental limit. 3) Scattering at such low neutrino energies has never been studied and any departure from the expected behavior may be an indication of new physics beyond the standard model. In this work we mainly focus on the various theoretical issues involved including a precise determination of the Weinberg angle at very low momentum transfer.Comment: 16 Pages, LaTex, 7 figures, talk given at NANP 2003, Dubna, Russia, June 23, 200

    Many-body effects in 16O(e,e'p)

    Get PDF
    Effects of nucleon-nucleon correlations on exclusive (e,ep)(e,e'p) reactions on closed-shell nuclei leading to single-hole states are studied using 16O(e,ep)15N^{16}O(e,e'p)^{15}N (6.326.32 MeV, 3/23/2^-) as an example. The quasi-hole wave function, calculated from the overlap of translationally invariant many-body variational wave functions containing realistic spatial, spin and isospin correlations, seems to describe the initial state of the struck proton accurately inside the nucleus, however it is too large at the surface. The effect of short-range correlations on the final state is found to be largely cancelled by the increase in the transparency for the struck proton. It is estimated that the values of the spectroscopic factors obtained with the DWIA may increase by a few percent due to correlation effects in the final state.Comment: 21 Pages, PHY-7849-TH-9

    Strange form factors of the proton: a new analysis of the neutrino (antineutrino) data of the BNL-734 experiment

    Full text link
    We consider ratios of elastic neutrino(antineutrino)-proton cross sections measured by the Brookhaven BNL-734 experiment and use them to obtain the neutral current (NC) over charged current (CC) neutrino-antineutrino asymmetry. We discuss the sensitivity of these ratios and of the asymmetry to the electric, magnetic and axial strange form factors of the nucleon and to the axial cutoff mass M_A. We show that the effects of the nuclear structure and interactions on the asymmetry and, in general, on ratios of cross sections are negligible. We find some restrictions on the possible values of the parameters characterizing the strange form factors. We show that a precise measurement of the neutrino-antineutrino asymmetry would allow the extraction of the axial and vector magnetic strange form factors in a model independent way. The neutrino-antineutrino asymmetry turns out to be almost independent on the electric strange form factor and on the axial cutoff mass.Comment: 12 page

    New pixelized Micromegas detector for the COMPASS experiment

    Get PDF
    New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for the present detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Studies were done with the present detectors moved in the beam, and two first pixelized prototypes are being tested with muon and hadron beams in real conditions at COMPASS. We present here this new project and report on two series of tests, with old detectors moved into the beam and with pixelized prototypes operated in real data taking condition with both muon and hadron beams.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous Detectors conference (MPGD2009), 12-15 June 2009, Kolympari, Crete, Greece Minor details added and language corrections don

    Quantum Einstein-Maxwell Fields: A Unified Viewpoint from the Loop Representation

    Get PDF
    We propose a naive unification of Electromagnetism and General Relativity based on enlarging the gauge group of Ashtekar's new variables. We construct the connection and loop representations and analyze the space of states. In the loop representation, the wavefunctions depend on two loops, each of them carrying information about both gravitation and electromagnetism. We find that the Chern-Simons form and the Jones Polynomial play a role in the model.Comment: 13pp. no figures, Revtex, UU-HEP-92/9, IFFI 92-1

    Realistic Model of the Nucleon Spectral Function in Few- and Many- Nucleon Systems

    Get PDF
    By analysing the high momentum features of the nucleon momentum distribution in light and complex nuclei, it is argued that the basic two-nucleon configurations generating the structure of the nucleon Spectral Function at high values of the nucleon momentum and removal energy, can be properly described by a factorised ansatz for the nuclear wave function, which leads to a nucleon Spectral Function in the form of a convolution integral involving the momentum distributions describing the relative and center-of-mass motion of a correlated nucleon-nucleon pair embedded in the medium. The Spectral Functions of 3He^3He and infinite nuclear matter resulting from the convolution formula and from many-body calculations are compared, and a very good agreement in a wide range of values of nucleon momentum and removal energy is found. Applications of the model to the analysis of inclusive and exclusive processes are presented, illustrating those features of the cross section which are sensitive to that part of the Spectral Function which is governed by short-range and tensor nucleon-nucleon correlations.Comment: 40 pages Latex , 16 ps figures available from the above e-mail address or from [email protected]

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06
    corecore