907 research outputs found

    Pacing in hypertrophic obstructive cardiomyopathy: A randomized crossover study

    Get PDF
    Background Uncontrolled studies have shown that short atrioventricular delay dual chamber pacing reduces outflow tract obstruction in hypertrophic obstructive cardiomyopathy. Although the exact mechanism of this beneficial effect is unclear, this seems a promising potential new treatment for hypertrophic obstructive cardiomyopathy. Method In order to evaluate the impact of pacing therapy, we performed a randomized multicentre double-blind crossover (pacemaker activated vs non activated) study to investigate modification of echocardiography, exercise tolerance, angina, dyspnoea and quality of life in 83 patients with a mean age of 53 (range 22-87) years with symptoms refractory or intolerant to classical drug treatment. Results After 12 weeks of activated or inactivated pacing, independent of which phase was first, the pressure gradient fell from 59±36 mmHg to 30±25 mmHg (P<0·001) with active pacing. Exercise tolerance improved by 21% in those patients who at baseline tolerated less than 10 min of Bruce protocol; symptoms of dyspnoea and angina also improved significantly from NYHA class 2·4 to 1·4 and 1·0 to 0·4, respectively (P<0·007). Quality of life assessment with a validated questionnaire objectivated the subjective improvement. Conclusion Pacemaker therapy is of clinical and haemodynamic benefit for patients with hypertrophic obstructive cardiomyopathy, left ventricular outflow gradient at rest over 30 mmHg who are symptomatic despite drug treatmen

    Nonlinear ac response of anisotropic composites

    Full text link
    When a suspension consisting of dielectric particles having nonlinear characteristics is subjected to a sinusoidal (ac) field, the electrical response will in general consist of ac fields at frequencies of the higher-order harmonics. These ac responses will also be anisotropic. In this work, a self-consistent formalism has been employed to compute the induced dipole moment for suspensions in which the suspended particles have nonlinear characteristics, in an attempt to investigate the anisotropy in the ac response. The results showed that the harmonics of the induced dipole moment and the local electric field are both increased as the anisotropy increases for the longitudinal field case, while the harmonics are decreased as the anisotropy increases for the transverse field case. These results are qualitatively understood with the spectral representation. Thus, by measuring the ac responses both parallel and perpendicular to the uniaxial anisotropic axis of the field-induced structures, it is possible to perform a real-time monitoring of the field-induced aggregation process.Comment: 14 pages and 4 eps figure

    Abnormal ECG Findings in Athletes: Clinical Evaluation and Considerations.

    Get PDF
    PURPOSE OF REVIEW: Pre-participation cardiovascular evaluation with electrocardiography is normal practice for most sporting bodies. Awareness about sudden cardiac death in athletes and recognizing how screening can help identify vulnerable athletes have empowered different sporting disciplines to invest in the wellbeing of their athletes. RECENT FINDINGS: Discerning physiological electrical alterations due to athletic training from those representing cardiac pathology may be challenging. The mode of investigation of affected athletes is dependent on the electrical anomaly and the disease(s) in question. This review will highlight specific pathological ECG patterns that warrant assessment and surveillance, together with an in-depth review of the recommended algorithm for evaluation

    Initial Independent Outcomes from Focal Impulse and Rotor Modulation Ablation for Atrial Fibrillation: Multicenter FIRM Registry

    Get PDF
    Introduction The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. Methods We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View™; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. Results Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145–354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). Conclusions Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center’s first cases
    corecore