19,899 research outputs found

    Endurance test and evaluation of alkaline water electrolysis cells

    Get PDF
    Utilization in the development of multi-kW low orbit power systems is discussed. The following technological developments of alkaline water electrolysis cells for space power application were demonstrated: (1) four 92.9 cm2 single water electrolysis cells, two using LST's advanced anodes and two using LST's super anodes; (2) four single cell endurance test stands for life testing of alkaline water electrolyte cells; (3) the solid performance of the advanced electrode and 355 K; (4) the breakthrough performance of the super electrode; (5) the four single cells for over 5,000 hours each significant cell deterioration or cell failure. It is concluded that the static feed water electrolysis concept is reliable and due to the inherent simplicity of the passive water feed mechanism coupled with the use of alkaline electrolyte has greater potential for regenerative fuel cell system applications than alternative electrolyzers. A rise in cell voltage occur after 2,000-3,000 hours which was attributed to deflection of the polysulfone end plates due to creepage of the thermoplastic. More end plate support was added, and the performance of the cells was restored to the initial performance level

    Improved charge injection device and a focal plane interface electronics board for stellar tracking

    Get PDF
    An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered

    Analysis of GOES imagery and digitized data for the SEV-UPS period, August 1979

    Get PDF
    In support of the Southeastern Virginia Urban Plume Study (SEV-UPS), GOES satellite imagery was analyzed for the month of August 1979. The analyzed GOES images provide an additional source of meteorological input useful in the evaluation of air quality data collected during the month long period of the SEV-UPS experiment. In addition to the imagery analysis, GOES digitized data were analyzed for the period of August 6 to 11, during which a regional haze pattern was detectable in the imagery. The results of the study indicate that the observed haze patterns correspond closely with areas shown in surface based measurements to have reduced visibilities and elevated pollution levels. Moreover, the results of the analysis of digitized data indicate that digital reflectance counts can be directly related to haze intensity both over land and ocean. The model results agree closely with the observed GOES digital reflectance counts, providing further indication that satellite remote sensing can be a useful tool for monitoring regional elevated pollution episodes

    Evaluation of the effects of varying moisture contents on microwave thermal emissions from agriculture fields

    Get PDF
    Three tasks related to soil moisture sensing at microwave wavelengths were undertaken: (1) analysis of data at L, X and K sub 21 band wavelengths over bare and vegetated fields from the 1975 NASA sponsored flight experiment over Phoenix, Arizona; (2) modeling of vegetation canopy at microwave wavelengths taking into consideration both absorption and volume scattering effects; and (3) investigation of overall atmospheric effects at microwave wavelengths that can affect soil moisture retrieval. Data for both bare and vegetated fields are found to agree well with theoretical estimates. It is observed that the retrieval of surface and near surface soil moisture information is feasible through multi-spectral and multi-temporal analysis. It is also established that at long wavelengths, which are optimal for surface sensing, atmospheric effects are generally minimal. At shorter wavelengths, which are optimal for atmosheric retrieval, the background surface properties are also established

    Scheduling the Belgian soccer league.

    Get PDF
    Scheduling; International; Theory;

    An evaluation of the spatial resolution of soil moisture information

    Get PDF
    Rainfall-amount patterns in the central regions of the U.S. were assessed. The spatial scales of surface features and their corresponding microwave responses in the mid western U.S. were investigated. The usefulness for U.S. government agencies of soil moisture information at scales of 10 km and 1 km. was ascertained. From an investigation of 494 storms, it was found that the rainfall resulting from the passage of most types of storms produces patterns which can be resolved on a 10 km scale. The land features causing the greatest problem in the sensing of soil moisture over large agricultural areas with a radiometer are bodies of water. Over the mid-western portions of the U.S., water occupies less than 2% of the total area, the consequently, the water bodies will not have a significant impact on the mapping of soil moisture. Over most of the areas, measurements at a 10-km resolution would adequately define the distribution of soil moisture. Crop yield models and hydrological models would give improved results if soil moisture information at scales of 10 km was available

    Analysis of band-gap formation in squashed arm-chair CNT

    Full text link
    The electronic properties of squashed arm-chair carbon nanotubes are modeled using constraint free density functional tight binding molecular dynamics simulations. Independent from CNT diameter, squashing path can be divided into {\it three} regimes. In the first regime, the nanotube deforms with negligible force. In the second one, there is significantly more resistance to squashing with the force being ∼40−100\sim 40-100 nN/per CNT unit cell. In the last regime, the CNT looses its hexagonal structure resulting in force drop-off followed by substantial force enhancement upon squashing. We compute the change in band-gap as a function of squashing and our main results are: (i) A band-gap initially opens due to interaction between atoms at the top and bottom sides of CNT. The π−\pi-orbital approximation is successful in modeling the band-gap opening at this stage. (ii) In the second regime of squashing, large π−σ\pi-\sigma interaction at the edges becomes important, which can lead to band-gap oscillation. (iii) Contrary to a common perception, nanotubes with broken mirror symmetry can have {\it zero} band-gap. (iv) All armchair nanotubes become metallic in the third regime of squashing. Finally, we discuss both differences and similarities obtained from the tight binding and density functional approaches.Comment: 16 pages and 6 figures, To appear in PR

    Recent developments in CID imaging

    Get PDF
    Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated

    Static Feed Water Electrolysis Subsystem Testing and Component Development

    Get PDF
    A program was carried out to develop and test advanced electrochemical cells/modules and critical electromechanical components for a static feed (alkaline electrolyte) water electrolysis oxygen generation subsystem. The accomplishments were refurbishment of a previously developed subsystem and successful demonstration for a total of 2980 hours of normal operation; achievement of sustained one-person level oxygen generation performance with state-of-the-art cell voltages averaging 1.61 V at 191 ASF for an operating temperature of 128F (equivalent to 1.51V when normalized to 180F); endurance testing and demonstration of reliable performance of the three-fluid pressure controller for 8650 hours; design and development of a fluid control assembly for this subsystem and demonstration of its performance; development and demonstration at the single cell and module levels of a unitized core composite cell that provides expanded differential pressure tolerance capability; fabrication and evaluation of a feed water electrolyte elimination five-cell module; and successful demonstration of an electrolysis module pressurization technique that can be used in place of nitrogen gas during the standby mode of operation to maintain system pressure and differential pressures

    Alloreactive cytotoxic T lymphocytes generated in the presence of viral- derived peptides show exquisite peptide and MHC specificity

    Get PDF
    The nature of alloreactivity to MHC molecules has been enigmatic, primarily because of the observation that allogeneic responses are considerably stronger than syngeneic responses. To better determine the specificity potential of allogeneic responses, we have generated alloreactive CTL specific for exogenous, viral-derived peptide ligands. This approach allowed us to critically evaluate both the peptide- and MHC-specificity of these alloreactive T cells. Exploiting the accessibility of the H-2Ld class I molecule for exogenous peptide ligands, alloreactive CTL were generated that are specific for either murine cytomegalovirus (MCMV) or lymphocytic choriomeningitis virus (LCMV) peptides bound by Ld alloantigens. Peptide specificity was initially observed in bulk cultures of alloreactive CTL only when tested on peptide-sensitized T2.Ld target cells that have defective presentation of endogenous peptides. Subsequent cloning of bulk alloreactive CTL lines generated to MCMV yielded CTL clones that had exquisitely specific MCMV peptide recognition requirement. All of the MCMV/Ld alloreactive CTL clones were also exquisitely MHC-specific in that none of the CTL clones lysed targets expressing MCMV/Lq complexes, even though Lq differs from Ld by only six amino acid residues and Lq also binds the MCMV peptide. This observation clearly demonstrates that alloreactive CTL are capable of the same degree of specificity for target cell recognition as are syngeneic CTL in MHC-restricted responses
    • …
    corecore