271 research outputs found

    Absolute frequency measurement of the magnesium intercombination transition 1S03P1^1S_0 \to ^3P_1

    Full text link
    We report on a frequency measurement of the (3s2)1S0(3s3p)3P1(3s^2)^1S_0\to(3s3p)^3P_1 clock transition of 24^{24}Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of a femtosecond fiber laser frequency comb. The achieved uncertainty is 2.5×10122.5\times10^{-12} which corresponds to an increase in accuracy of six orders of magnitude compared to previous results. The measured frequency value permits the calculation of several other optical transitions from 1S0^1S_0 to the 3PJ^3P_J-level system for 24^{24}Mg, 25^{25}Mg and 26^{26}Mg. We describe in detail the components of our optical frequency standard like the stabilized spectroscopy laser, the atomic beam apparatus used for Ramsey-Bord\'e interferometry and the frequency comb generator and discuss the uncertainty contributions to our measurement including the first and second order Doppler effect. An upper limit of 3×10133\times10^{-13} in one second for the short term instability of our optical frequency standard was determined by comparison with a GPS disciplined quartz oscillator.Comment: 8 pages, 8 figure

    A retrospective in-depth analysis of continuous glucose monitoring datasets for patients with hepatic glycogen storage disease:Recommended outcome parameters for glucose management

    Get PDF
    Continuous glucose monitoring (CGM) systems have great potential for real-time assessment of glycemic variation in patients with hepatic glycogen storage disease (GSD). However, detailed descriptions and in-depth analysis of CGM data from hepatic GSD patients during interventions are scarce. This is a retrospective in-depth analysis of CGM parameters, acquired in a continuous, real-time fashion describing glucose management in 15 individual GSD patients. CGM subsets are obtained both in-hospital and at home, upon nocturnal dietary intervention (n = 1), starch loads (n = 11) and treatment of GSD Ib patients with empagliflozin (n = 3). Descriptive CGM parameters, and parameters reflecting glycemic variation and glycemic control are considered useful CGM outcome parameters. Furthermore, the combination of first and second order derivatives, cumulative sum and Fourier analysis identified both subtle and sudden changes in glucose management; hence, aiding assessment of dietary and medical interventions. CGM data interpolation for nocturnal intervals reduced confounding by physical activity and diet. Based on these analyses, we conclude that in-depth CGM analysis can be a powerful tool to assess glucose management and optimize treatment in individual hepatic GSD patients

    Growth of High-Mobility Bi2Te2Se Nanoplatelets on hBN Sheets by van der Waals Epitaxy

    Full text link
    The electrical detection of the surface states of topological insulators is strongly impeded by the interference of bulk conduction, which commonly arises due to pronounced doping associated with the formation of lattice defects. As exemplified by the topological insulator Bi2Te2Se, we show that via van der Waals epitaxial growth on thin hBN substrates the structural quality of such nanoplatelets can be substantially improved. The surface state carrier mobility of nanoplatelets on hBN is increased by a factor of about 3 compared to platelets on conventional Si/SiOx substrates, which enables the observation of well-developed Shubnikov-de Haas oscillations. We furthermore demonstrate the possibility to effectively tune the Fermi level position in the films with the aid of a back gate

    Modeling the properties of carbon nanotubes for sensor-based devices

    Get PDF
    We acknowledge funding from the European Community through NoE Nanoquanta (NMP4-CT-2004-500198), SANES (NMP4-T-2006-017310), DNA-NANODEVICES (IST-2006-029192) and NANO-ERA Chemistry projects, UPV/EHU (SGIker Arina) and the Basque Governement.Peer reviewe

    Mapping of functionalized regions on carbon nanotubes by scanning tunneling microscopy

    Full text link
    Scanning tunneling microscopy (STM) gives us the opportunity to map the surface of functionalized carbon nanotubes in an energy resolved manner and with atomic precision. But this potential is largely untapped, mainly due to sample stability issues which inhibit reliable measurements. Here we present a simple and straightforward solution that makes away with this difficulty, by incorporating the functionalized multiwalled carbon nanotubes (MWCNT) into a few layer graphene - nanotube composite. This enabled us to measure energy resolved tunneling conductance maps on the nanotubes, which shed light on the level of doping, charge transfer between tube and functional groups and the dependence of defect creation or functionalization on crystallographic orientation.Comment: Keywords: functionalization, carbon nanotubes, few layer graphene, STM, CITS, ST

    High Electron Mobility in Vacuum and Ambient for PDIF-CN2 Single-Crystal Transistors

    Full text link
    We have investigated the electron mobility on field-effect transistors based on PDIF-CN2_{2} single crystals. The family of the small molecules PDI8-CN2_{2} has been chosen for the promising results obtained for vapour-deposited thin film FETs. We used as gate dielectric a layer of PMMA (spinned on top of the SiO2_{2}), to reduce the possibility of electron trapping by hydroxyl groups present at surface of the oxide. For these devices we obtained a room temperature mobility of 6 cm2^{2}/Vs in vacuum and 3 cm2^{2}/Vs in air. Our measurements demonstrate the possibility to obtain n-type OFETs with performances comparable to those of p-type devices.Comment: published online in JAC
    corecore