3,917 research outputs found
Study and design of a cryogenic propellant acquisition system
The development of an acquisition system for supplying subcooled liquid hydrogen and liquid oxygen under in-orbit conditions is discussed. The system will be applied to the integrated cryogenic feed requirements for space systems such as a space shuttle cryogenic auxiliary propulsion system (APS) and main propulsion for an advanced spacecraft propulsion module (ASPM). Concepts that use the favorable surface tension characteristics of fine mesh screens are emphasized. The specific objectives of the program are: (1) to evolve conceptual designs for candidate acquisition systems, (2) to formulate the analytical models needed to analyze the systems, and (3) to generate parametric data on overall candidate system performance, characteristics, and operational features in sufficient depth to establish critical design problems and criteria to support a sound system design and evaluation
Study and design of cryogenic propellant acquisition systems. Volume 2: Supporting experimental program
Areas of cryogenic fuel systems were identified where critical experimental information was needed either to define a design criteria or to establish the feasibility of a design concept or a critical aspect of a particular design. Such data requirements fell into three broad categories: (1) basic surface tension screen characteristics; (2) screen acquisition device fabrication problems; and (3) screen surface tension device operational failure modes. To explore these problems and to establish design criteria where possible, extensive laboratory or bench test scale experiments were conducted. In general, these proved to be quite successful and, in many instances, the test results were directly used in the system design analyses and development. In some cases, particularly those relating to operational-type problems, areas requiring future research were identified, especially screen heat transfer and vibrational effects
Randomised positive control trial of NSAID and antimicrobial treatment for calf fever caused by pneumonia
One hundred and fifty-four preweaning calves were followed between May and October 2015. Calves were fitted with continuous monitoring temperature probes (TempVerified FeverTag), programmed so a flashing light emitting diode (LED) light was triggered following six hours of a sustained ear canal temperature of ≥39.7°C. A total of 83 calves (61.9 per cent) developed undifferentiated fever, with a presumptive diagnosis of pneumonia through exclusion of other calf diseases. Once fever was detected, calves were randomly allocated to treatment groups. Calves in group 1 (NSAID) received 2 mg/kg flunixin meglumine (Allevinix, Merial) for three consecutive days and group 2 (antimicrobial) received 6 mg/kg gamithromycin (Zactran, Merial). If fever persisted for 72 hours after the initial treatment, calves were given further treatment (group 1 received antimicrobial and group 2 received NSAID). Calves in group 1 (NSAID) were five times more likely (P=0.002) to require a second treatment (the antimicrobial) after 72 hours to resolve the fever compared with the need to give group 2 (antimicrobial) calves a second treatment (NSAID). This demonstrates the importance of ongoing monitoring and follow-up of calves with respiratory disease. However, of calves with fever in group 1 (NSAID), 25.7 per cent showed resolution following NSAID-only treatment with no detrimental effect on the development of repeated fever or daily live weight gain. This suggests that NSAID alone may be a useful first-line treatment, provided adequate attention is given to ongoing monitoring to identify those cases that require additional antimicrobial treatment
A computational design of experiments based method for evaluation of off-the-shelf total knee replacement implants
A methodology to explore the design space of off-the-shelf total knee replacement implant designs is outlined. Generic femur component and tibia plate designs were scaled to thousands of sizes and virtually fitted to 244 test subjects. Various implant designs and sizing requirements between genders and ethnicities were evaluated. 5 sizes optimised via the methodology produced a good global fit for most subjects. However, clinically significant over/underhang was present in 19% of subjects for tibia plates and 25% for femur components, reducing to 11/20% with 8 sizes. The analysis highlighted subtly better fit performance was obtained using sizes with unequal spacing
Applying machine learning methods to enable automatic customisation of knee replacement implants from CT data
The aim of this study was to develop an automated pipeline capable of designing custom total knee replacement implants from CT scans. The developed pipeline firstly utilised a series of machine learning methods including classification, object detection, and image segmentation models, to extract geometrical information from inputted DICOM files. Statistical shape models then used the information to create femur and tibia 3D surface model predictions which were ultimately used by computer aided design scripts to generate customised implant designs. The developed pipeline was trained and tested using CT scan images, along with segmented 3D models, obtained for 98 Korean Asian subjects. The performance of the pipeline was tested computationally by virtually fitting outputted implant designs with ‘ground truth’ 3D models for each test subject’s bones. This demonstrated the pipeline was capable of repeatably producing highly accurate designs, and its performance was not impacted by subject sex, height, age, or knee side. In conclusion, a robust, accurate and automatic, CT-based total knee replacement customisation pipeline was shown to be feasible and could afford significant time and cost advantages over conventional methods. The pipeline framework could also be adapted to enable customisation of other medical implants
Clinical investigation of an outbreak of alveolitis and asthma in a car engine manufacturing plant
Background Exposure to metal working fluid (MWF) has been associated with outbreaks of EAA in the US, with bacterial contamination of MWF being a possible cause, but was uncommon in the UK. Twelve workers developed extrinsic allergic alveolitis (EAA) in a car engine manufacturing plant in the UK, presenting clinically between December 2003 and May 2004. This paper reports the subsequent epidemiological investigation of the whole workforce. This had three aims:-
• To measure the extent of the outbreak by identifying other workers who may have developed EAA or other work-related respiratory diseases.
• To provide case-detection so that those affected can be treated.
• To provide epidemiological data to identify the cause of the outbreak.
Methods The outbreak was investigated in a three-phase cross-sectional survey of the workforce.
Phase I A respiratory screening questionnaire was completed by 808/836 workers (96.7%) in May 2004.
Phase II 481 employees with at least one respiratory symptom on screening and 50 asymptomatic controls were invited for investigation at the factory in June 2004. This included a questionnaire, spirometry and clinical opinion. 454/481(94.4%) responded along with 48/50(96%) controls. Workers were identified who needed further investigation and serial measurements of peak expiratory flow (PEF).
Phase III 162 employees were seen at the Birmingham Occupational Lung Disease clinic. 198 employees returned PEF records, including 141 of the 162 who attended for clinical investigation. Case definitions for diagnoses were agreed.
Results 87 workers (10.4% of workforce) met case definitions for occupational lung disease, comprising EAA(19), occupational asthma(74) and humidifier fever(7). 12 workers had more than one diagnosis. The peak onset of work-related breathlessness was Spring 2003. The proportion of workers affected was higher for those using metal working fluid (MWF) from a large sump(27.3%) compared with working all over the manufacturing area (7.9%) (OR=4.39,p<0.001). Two workers had positive specific provocation tests to the used but not the unused MWF solution.
Conclusions Extensive investigation of the outbreak of EAA detected a large number of affected workers, not only with EAA but also occupational asthma. This is the largest reported outbreak in Europe. Mist from used MWF is the likely cause. In workplaces using MWF, there is a need to carry out risk assessments, to monitor and maintain fluid quality, to control mist and to carry out respiratory health surveillance
Application of qPCR Technologies in Stormwater Source Tracking and Determination of Host Contributions of Fecal Indicator Bacteria
2012 S.C. Water Resources Conference - Exploring Opportunities for Collaborative Water Research, Policy and Managemen
Study and design of cryogenic propellant acquisition systems. Volume 1: Design studies
An in-depth study and selection of practical propellant surface tension acquisition system designs for two specific future cryogenic space vehicles, an advanced cryogenic space shuttle auxiliary propulsion system and an advanced space propulsion module is reported. A supporting laboratory scale experimental program was also conducted to provide design information critical to concept finalization and selection. Designs using localized pressure isolated surface tension screen devices were selected for each application and preliminary designs were generated. Based on these designs, large scale acquisition prototype hardware was designed and fabricated to be compatible with available NASA-MSFC feed system hardware
- …