2,247 research outputs found
Laboratory von H\'amos X-ray Spectroscopy for Routine Sample Characterization
High energy resolution, hard X-ray spectroscopies are powerful element
selective probes of the electronic and local structure of matter, with diverse
applications in chemistry, physics, biology and materials science. The routine
application of these techniques is hindered by the complicated and slow access
to synchrotron radiation facilities. Here we propose a new, economic, easily
operated laboratory high resolution von H\'amos type X-ray spectrometer, which
offers rapid transmission experiments for X-ray absorption, and is also capable
of recording X-ray emission spectra. The use of a cylindrical analyzer crystal
and a position sensitive detector enabled us to build a maintenance free,
flexible setup with low operational costs, while delivering synchrotron grade
signal to noise measurements in reasonable acquisition times. We demonstrate
the proof of principle and give examples for both measurement types. Finally,
tracking of a several day long chemical transformation, a case better suited
for laboratory than synchrotron investigation, is also presented
A star-forming galaxy at z= 5.78 in the Chandra Deep Field South
We report the discovery of a luminous z = 5.78 star-forming galaxy in the Chandra Deep Field South. This galaxy was selected as an ‘i-drop’ from the GOODS public survey imaging with the Hubble Space Telescope/Advanced Camera for Surveys (object 3 in the work of Stanway, Bunker & McMahon 2003). The large colour of (i′−z′)AB = 1.6 indicated a spectral break consistent with the Lyman α forest absorption shortward of Lyman α at z≈ 6. The galaxy is very compact (marginally resolved with ACS with a half-light radius of 0.08 arcsec, so rhl 5. Our spectroscopic redshift for this object confirms the validity of the i′-drop technique of Stanway et al. to select star-forming galaxies atz≈ 6
Construction and measurements of a vacuum-swing-adsorption radon-mitigation system
Long-lived alpha and beta emitters in the Rn decay chain on (and
near) detector surfaces may be the limiting background in many experiments
attempting to detect dark matter or neutrinoless double-beta decay, and in
screening detectors. In order to reduce backgrounds from radon-daughter
plate-out onto the wires of the BetaCage during its assembly, an
ultra-low-radon cleanroom is being commissioned at Syracuse University using a
vacuum-swing-adsorption radon-mitigation system. The radon filter shows
~20 reduction at its output, from 7.470.56 to 0.370.12
Bq/m, and the cleanroom radon activity meets project requirements, with a
lowest achieved value consistent with that of the filter, and levels
consistently < 2 Bq/m.Comment: 5 pages, 3 figures, Proceedings of Low Radioactivity Techniques (LRT)
2013, Gran Sasso, Italy, April 10-12, 201
XAFS Debye-Waller factors for deformed hemes and metal substituted hemes
We present an efficient and accurate method for calculating XAFS Debye-Waller factors for deformed active sites of hemoproteins and metal substituted hemes. Based on the Normal Coordinate Structural Decomposition scheme, the deformation of the porphyrin macrocycle is expressed as a linear combination of the normal modes of the planar species. In our approach, we identify the modes that contribute most to the deformation. Small metal-porphyrin structures which match the macrocycle structural deformation of the deformed hemoprotein site are used to calculate the Debye-Waller parameters at sample\u27s temperature. The Debye-Waller factors are directly obtained by calculating the normal mode spectrum of the corresponding metal-porphyrin structure using Density Functional Theory. Our method is tested on Ni-tetraadamantyl porphyrin and cytochrome c structures with more than 500 available scattering paths. © 2009 IOP Publishing Ltd
Longitudinal magnetic excitations in classical spin systems
Using spin dynamics simulations we predict the splitting of the longitudinal
spin wave peak in all antiferromagnets with single site anisotropy into two
peaks separated by twice the energy gap at the Brillouin zone center. This
phenomenon has yet to be observed experimentally but can be easily investigated
through neutron scattering experiments on MnF and FeF. We have also
determined that for all classical Heisenberg models the longitudinal
propagative excitations are entirely multiple spin-wave in nature.Comment: four pages three figures, the last two postscript files are two parts
of the third figur
Recommended from our members
Notations and conventions in molecular spectroscopy: part 1. General spectroscopic notation
The field of Molecular Spectroscopy was surveyed in order to determine a set of
conventions and symbols which are in common use in the spectroscopic literature. This
document, which is Part I in a series, establishes the notations and conventions used for
general spectroscopic notations and deals with quantum mechanics, quantum numbers
(vibrational states, angular momentum and energy levels), spectroscopic transitions, and
miscellaneous notations (e.g. spectroscopic terms). Further parts will follow, dealing inter
alia with symmetry notation, permutation and permutation-inversion symmetry notation,
vibration-rotation spectroscopy and electronic spectroscopy
Hydrogeology and stratigraphy of the Dakota formation in Northwest Iowa
https://ir.uiowa.edu/igs_wsb/1012/thumbnail.jp
Cold guided beams of water isotopologs
Electrostatic velocity filtering and guiding is an established technique to
produce high fluxes of cold polar molecules. In this paper we clarify different
aspects of this technique by comparing experiments to detailed calculations. In
the experiment, we produce cold guided beams of the three water isotopologs
H2O, D2O and HDO. Their different rotational constants and orientations of
electric dipole moments lead to remarkably different Stark shift properties,
despite the molecules being very similar in a chemical sense. Therefore, the
signals of the guided water isotopologs differ on an absolute scale and also
exhibit characteristic electrode voltage dependencies. We find excellent
agreement between the relative guided fractions and voltage dependencies of the
investigated isotopologs and predictions made by our theoretical model of
electrostatic velocity filtering.Comment: 14 pages, 13 figures; small changes to the text, updated reference
- …