9,773 research outputs found

    Latin America and the Mexican Conference

    Get PDF
    n/

    Hypersonic test facility Patent

    Get PDF
    Hypersonic test facility for studying ablation in models under high pressure and high temperatur

    Kinetic pathways of multi-phase surfactant systems

    Full text link
    The relaxation following a temperature quench of two-phase (lamellar and sponge phase) and three-phase (lamellar, sponge and micellar phase) samples, has been studied in an SDS/octanol/brine system. In the three-phase case we have observed samples that are initially mainly sponge phase with lamellar and micellar phase on the top and bottom respectively. Upon decreasing temperature most of the volume of the sponge phase is replaced by lamellar phase. During the equilibriation we have observed three regimes of behaviour within the sponge phase: (i) disruption in the sponge texture, then (ii) after the sponge phase homogenises there is a lamellar nucleation regime and finally (iii) a bizarre plume connects the lamellar phase with the micellar phase. The relaxation of the two-phase sample proceeds instead in two stages. First lamellar drops nucleate in the sponge phase forming a onion `gel' structure. Over time the lamellar structure compacts while equilibriating into a two phase lamellar/sponge phase sample. We offer possible explanatioins for some of these observations in the context of a general theory for phase kinetics in systems with one fast and one slow variable.Comment: 1 textfile, 20 figures (jpg), to appear in PR

    The 1st Balloon Valvuloplasty: An Historical Note

    Get PDF
    Balloon valvuloplasty (BV) is currently the treatment of choice for pulmonic stenosis in humans and dogs. Before permission was obtained to attempt the 1st BV in a child in 1982, the safety and efficacy of the procedure were tested in 1980 in an English Bulldog with spontaneous pulmonic stenosis. A fatal outcome would have caused indefinite postponement of BV in human patients, a procedure that currently benefits over 25,000 patients a year worldwide. This article describes the initial test procedure and its fortunate outcome in spite of unrecognized coronary anomalies in the bulldog. A small balloon was used in the test procedure, and fatal disruption of the anomalous left coronary artery (CA) did not occur as it has in several bulldogs since that time

    Instability of Myelin Tubes under Dehydration: deswelling of layered cylindrical structures

    Full text link
    We report experimental observations of an undulational instability of myelin figures. Motivated by this, we examine theoretically the deformation and possible instability of concentric, cylindrical, multi-lamellar membrane structures. Under conditions of osmotic stress (swelling or dehydration), we find a stable, deformed state in which the layer deformation is given by \delta R ~ r^{\sqrt{B_A/(hB)}}, where B_A is the area compression modulus, B is the inter-layer compression modulus, and h is the repeat distance of layers. Also, above a finite threshold of dehydration (or osmotic stress), we find that the system becomes unstable to undulations, first with a characteristic wavelength of order \sqrt{xi d_0}, where xi is the standard smectic penetration depth and d_0 is the thickness of dehydrated region.Comment: 5 pages + 3 figures [revtex 4

    Power-law random walks

    Full text link
    We present some new results about the distribution of a random walk whose independent steps follow a qq-Gaussian distribution with exponent 11q;qR\frac{1}{1-q}; q \in \mathbb{R}. In the case q>1q>1 we show that a stochastic representation of the point reached after nn steps of the walk can be expressed explicitly for all nn. In the case q<1,q<1, we show that the random walk can be interpreted as a projection of an isotropic random walk, i.e. a random walk with fixed length steps and uniformly distributed directions.Comment: 5 pages, 4 figure

    Coiling Instabilities in Multilamellar Tubes

    Full text link
    Myelin figures are densely packed stacks of coaxial cylindrical bilayers that are unstable to the formation of coils or double helices. These myelin figures appear to have no intrinsic chirality. We show that such cylindrical membrane stacks can develop an instability when they acquire a spontaneous curvature or when the equilibrium distance between membranes is decreased. This instability breaks the chiral symmetry of the stack and may result in coiling. A unilamellar cylindrical vesicle, on the other hand, will develop an axisymmetric instability, possibly related to the pearling instability.Comment: 6 pages, 2 figure

    COVARIANCE ADJUSTMENT IN STUDIES INVOLVING OBSERVATIONAL FACTORS OR COVARIATES INFLUENCED BY TREATMENTS

    Get PDF
    We extend the definition of adjusted treatment means in the analysis of covariance to deal with the case where some of the covariates are influenced by treatments or where some of the factors are observational. In these cases, comparison of treatment means adjusted to a common value of the covariate may be inappropriate. Partially adjusted means are defined and it is shown that special cases include the usual adjusted means (adjusted to a common value for each of the covariates) and unadjusted means. In fact, in a multifactorial experiment, one can, by appropriate choice of adjustment, compare adjusted means for one factor but unadjusted means for the second factor. Partially adjusted means can be computed by any linear models software which will estimate linear combinations of the parameters

    Coiling Instability of Multilamellar Membrane Tubes with Anchored Polymers

    Full text link
    We study experimentally a coiling instability of cylindrical multilamellar stacks of phospholipid membranes, induced by polymers with hydrophobic anchors grafted along their hydrophilic backbone. Our system is unique in that coils form in the absence of both twist and adhesion. We interpret our experimental results in terms of a model in which local membrane curvature and polymer concentration are coupled. The model predicts the occurrence of maximally tight coils above a threshold polymer occupancy. A proper comparison between the model and experiment involved imaging of projections from simulated coiled tubes with maximal curvature and complicated torsions.Comment: 11 pages + 7 GIF figures + 10 JPEG figure

    Morphological Observations of Mineralizing Pericardium Cardiac Grafts

    Get PDF
    Pericardial patch grafters were implanted in the hearts of young sheep for periods ranging from two to 120 days. Explants seven to 21 days old revealed the formation of a pseudoneointima (PNI) on the blood contacting surface of the pericardium. The PNI was more heavily mineralized than the pericardium. Mineralization was most intense on the blood contacting surface of the PNI and on the chamber surface of the pericardium. After three weeks of implantation, the PNI was much thinner and was organized into a thin fibrous capsule without any signs of mineralization. In the pericardium, mineral deposits were seen in fibroblasts. Moreover, cell-related mineralization was evident prior to calcification of the surrounding collagen matri
    corecore