868 research outputs found

    DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2lasers

    Get PDF
    A parametric analysis of DIAL sensitivity with heterodyne detection is presented and comparisons with direct detection are discussed. Examples are given for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system. Results indicate that maximum sensitivity at minimum laser energy per measurement requires multiple pulse operation with the energy per pulse selected so that the measured photon rate is approximately equal to the detector IF bandwidth. Measurement sensitivities can be maximized and interference effects minimized by fine adjustment of measurement frequencies using the tunability of high pressure lasers. The use of rare isotope lasers minimizes loss due to CO2 atmospheric absorption

    DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2 lasers

    Get PDF
    Atmospheric trace constituent measurements with higher vertical resolution than attainable with passive radiometers are discussed. Infrared differential absorption lidar (DIAL), which depends on Mie scattering from aerosols, has special advantages for tropospheric and lower stratospheric applications and has great potential importance for measurements from shuttle and aircraft. Differential absorption lidar data reduction involves comparing large amplitude signals which have small differences. The accuracy of the trace constituent concentration inferred from DIAL measurements depends strongly on the errors in determining the amplitude of the signals. Thus, the commonly used SNR expression (signal divided by noise in the absence of signal) is not adequate to describe DIAL measurement accuracy and must be replaced by an expression which includes the random coherent (speckle) noise within the signal. A comprehensive DIAL computer algorithm is modified to include heterodyne detection and speckle noise. Examples for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system are given

    Study of instabilities and transition to turbulence in a linear hall accelerator

    Get PDF
    Magnetospheric instabilities and transition to plasma turbulence in Hall current accelerator

    Development of flashlamp-pumped Q-switched Ho:Tm:Cr:YAG lasers for mid-infrared LIDAR application

    Get PDF
    A flashlamp-pumped 2.1 micron Ho:Tm:Cr:YAG laser was studied for both normal mode and Q-switched operations under a wide variety of experimental conditions in order to optimize performance. Laser output energy, slope efficiency, threshold and pulselength were determined as a function of operating temperature, output mirror reflectivity, input electrical energy and Q-switch opening time. The measured normal-mode laser thresholds of a Ho(3+) (0.45 atomic percent):Tm(3+) (2.5 atomic percent):Cr(3+) (0.8 atomic percent):YAG crystal ranged form 26 to 50 J between 120 and 200 K with slope efficiencies up to 0.36 percent with a 60 percent reflective output mirror. Under Q-switched operation the slope efficiency was 90 percent of the normal-mode result. Development of solid state lasers with Ho(3+), Tm(3+) and/or Er(3+) doped crystals has been pursued by NASA for eye-dafe mid-infrared LIDAR (light detection and ranging) application. As a part of the project, the authors have been working on evaluating Ho(3+):Tm(3+):Cr(3+):YAG crystals for normal-mode and Q-switched 2.1 micron laser operations in order to determine an optimum Tm(3+) concentration under flashlamp pumping conditions. Lasing properties of the Ho(3+) in the mid-infrared region have been studied by many research groups since the early 1960's. However, the technology of those lasers is still premature for lidar application. In order to overcome the inefficiency related to narrow absorption bands of the Ho(3+), Tm(3+) and Er(3+), the erbium has been replaced by chromium. The improvement in flashlamp-pumped Ho(3+) laser efficiency has been demonstrated recently by several research groups by utilizing the broad absorption spectrum of Cr(3+) which covers the flashlamp's emission spectrum. Efficient energy transfer to the Tm(3+) and then the Ho(3+) occurs subsequently. It is known that high Tm(3+) concentration and low Ho(3+) concentration are preferred to achieve a quantum efficiency approaching two and to avoid large reabsorption losses. However, determination of the optimum Tm(3+) concentration required to ensure efficient energy transfer from Cr(3+) to Tm(3+) and from Tm(3+) to Ho(3+) has not been made in the Ho:Tm:CR:YAG crystal. The results obtained so far are given

    Measuring the Plasticity of Social Approach: A Randomized Controlled Trial of the Effects of the PEERS Intervention on EEG Asymmetry in Adolescents with Autism Spectrum Disorders

    Get PDF
    This study examined whether the Program for the Education and Enrichment of Relational Skills (PEERS: Social skills for teenagers with developmental and autism spectrum disorders: The PEERS treatment manual, Routledge, New York, 2010a) affected neural function, via EEG asymmetry, in a randomized controlled trial of adolescents with Autism spectrum disorders (ASD) and a group of typically developing adolescents. Adolescents with ASD in PEERS shifted from right-hemisphere gamma-band EEG asymmetry before PEERS to left-hemisphere EEG asymmetry after PEERS, versus a waitlist ASD group. Left-hemisphere EEG asymmetry was associated with more social contacts and knowledge, and fewer symptoms of autism. Adolescents with ASD in PEERS no longer differed from typically developing adolescents in left-dominant EEG asymmetry at post-test. These findings are discussed via the Modifier Model of Autism (Mundy et al. in Res Pract Persons Severe Disabl 32(2):124, 2007), with emphasis on remediating isolation/withdrawal in ASD

    Surgical valvulotomy for tricuspid valve stenosis in a dog

    Get PDF
    A 2 year 4 month old female neutered Labrador retriever was presented for evaluation right sided congestive heart failure. Echocardiographic examination revealed tricuspid valve dysplasia with only two small orifices in the valve resulting in severe tricuspid stenosis. The dog underwent a right fifth lateral intercostal thoracotomy and surgical tricuspid valvulotomy, under cardiopulmonary bypass. The stenosis was relieved by dividing the valve leaflets between the two orifices with continuation to the commissures, creating a ‘bi-leaflet’ valve. The dog made a good recovery initially with echocardiography at 48 hours after surgery showing a reduction in tricuspid valve E and A wave velocities and pressure half time (from 230 ms to to 65 ms). She was discharged five days after surgery with spironolactone, benazepril, pimobendan and clopidogrel. The dog was re-presented two days later having collapsed, with pyrexia, facial swelling and pitting edema on the ventral neck and intermandibular region. Investigations did not reveal an underlying cause and the clinical signs resolved with supportive therapy. Two years after surgery the dog was free of clinical signs with normal exercise tolerance and only mild tricuspid regurgitation on echocardiography, with discontinuation of all medications

    Technological Devices in the Archives: A Policy Analysis

    Get PDF
    Doing research in the archive is the cornerstone of humanities scholarship. Various archives institute policies regarding the use of technological devices, such as mobile phones, laptops, and cameras in their reading rooms. Such policies directly affect the scholars as the devices mediate the nature of their interaction with the source materials in terms of capturing, organizing, note taking, and record keeping for future use of found materials. In this paper, we present our analysis of the policies of thirty archives regarding the use of technology in their reading rooms. This policy analysis, along with data from interviews of scholars and archivists, is intended to serve as a basis for developing mobile applications for assisting scholars in their research activities. In this paper we introduce an early prototype of such a mobile application— AMTracker.Informatio

    Modeling methanogenesis with a genome-scale metabolic reconstruction of Methanosarcina barkeri

    Get PDF
    We present a genome-scale metabolic model for the archaeal methanogen Methanosarcina barkeri. We characterize the metabolic network and compare it to reconstructions from the prokaryotic, eukaryotic and archaeal domains. Using the model in conjunction with constraint-based methods, we simulate the metabolic fluxes and resulting phenotypes induced by different environmental and genetic conditions. This represents the first large-scale simulation of either a methanogen or an archaeal species. Model predictions are validated by comparison to experimental growth measurements and phenotypes of M. barkeri on different substrates. The predicted growth phenotypes for wild type and mutants of the methanogenic pathway have a high level of agreement with experimental findings. We further examine the efficiency of the energy-conserving reactions in the methanogenic pathway, specifically the Ech hydrogenase reaction, and determine a stoichiometry for the nitrogenase reaction. This work demonstrates that a reconstructed metabolic network can serve as an analysis platform to predict cellular phenotypes, characterize methanogenic growth, improve the genome annotation and further uncover the metabolic characteristics of methanogenesis
    corecore