85 research outputs found

    Involving the public in restoring the role of fire in the longleaf pine ecosystem of Upland Island Wilderness

    Get PDF
    The 13,250-acre Upland Island Wilderness (UIW) in Texas was established in 1984 and is managed by the United States Forest Service (USFS). Historically, portions of it consisted of open and diverse longleaf pine (Pinus palustris) ecosystems which depend on frequent, low-intensity surface fires. As in many other relatively small wilderness areas, the vegetation and fuel conditions in the UIW underwent extensive changes after wilderness designation. Lightning-caused wildfires were no longer allowed to burn with the frequency or intensity that characterized the natural fire regime. This has resulted in an increase of shade-tolerant trees and shrubs, heavy accumulations of duff and pine litter, and loss of suitable habitat for several rare species, including the red-cockaded woodpecker (Picoides borealis). In addition, the unnatural fuel accumulations have created a serious fire hazard that threatens the safety of firefighters, private citizens, adjacent properties, and the wilderness resource itself

    Loss of mouse Stmn2 function causes motor neuropathy

    Get PDF
    Amyotrophic lateral sclerosis (ALS) is characterized by motor neuron degeneration accompanied by aberrant accumulation and loss of function of the RNA-binding protein TDP43. Thus far, it remains unresolved to what extent TDP43 loss of function directly contributes to motor system dysfunction. Here, we employed gene editing to find whether the mouse ortholog of the TDP43-regulated gene STMN2 has an important function in maintaining the motor system. Both mosaic founders and homozygous loss-of-function Stmn2 mice exhibited neuromuscular junction denervation and fragmentation, resulting in muscle atrophy and impaired motor behavior, accompanied by an imbalance in neuronal microtubule dynamics in the spinal cord. The introduction of human STMN2 through BAC transgenesis was sufficient to rescue the motor phenotypes observed in Stmn2 mutant mice. Collectively, our results demonstrate that disrupting the ortholog of a single TDP43-regulated RNA is sufficient to cause substantial motor dysfunction, indicating that disruption of TDP43 function is likely a contributor to ALS

    The initial U.S. experience with the Tempo active fixation temporary pacing lead in structural heart interventions

    Full text link
    ObjectivesThis multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead.BackgroundDespite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability.MethodsData from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed.ResultsThe Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device‐related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5–221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment.ConclusionThe Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/154941/1/ccd28476.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/154941/2/ccd28476_am.pd

    Stratification of Outcomes After Transcatheter Aortic Valve Replacement According to Surgical Inoperability for Technical Versus Clinical Reasons

    Get PDF
    ObjectivesThe goal of this study was to examine the impact of reasons for surgical inoperability on outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundPatients with severe aortic stenosis may be deemed inoperable due to technical or clinical reasons. The relative impact of each designation on early and late outcomes after TAVR is unclear.MethodsPatients were studied from the inoperable arm (cohort B) of the randomized PARTNER (Placement of Aortic Transcatheter Valve) trial and the nonrandomized continued access registry. Patients were classified according to whether they were classified as technically inoperable (TI) or clinically inoperable (CLI). Reasons for TI included porcelain aorta, previous mediastinal radiation, chest wall deformity, and potential for injury to previous bypass graft on sternal re-entry. Reasons for CLI were systemic factors that were deemed to make survival unlikely.ResultsOf the 369 patients, 23.0% were considered inoperable for technical reasons alone; the remaining were judged to be CLI. For TI, the most common cause was a porcelain aorta (42%); for CLI, it was multiple comorbidities (48%) and frailty (31%). Quality of life and 2-year mortality were significantly better among TI patients compared with CLI patients (mortality 23.3% vs. 43.8%; p < 0.001). Nonetheless, TAVR led to substantial survival benefits compared with standard therapy in both inoperable cohorts.ConclusionsPatients undergoing TAVR based solely on TI have better survival and quality of life improvements than those who are inoperable due to clinical comorbidities. Both TI and CLI TAVR have significant survival benefit in the context of standard therapy. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894

    Two-year outcomes after transcatheter or surgical aortic-valve replacement.

    Get PDF
    BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS: The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS: A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.)

    Prospective Study of TMVR Using Balloon-Expandable Aortic Transcatheter Valves in MAC: MITRAL Trial 1-Year Outcomes

    Get PDF
    OBJECTIVES: The aim of this study was to evaluate 1-year outcomes of valve-in-mitral annular calcification (ViMAC) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating the feasibility of ViMAC using balloon-expandable aortic transcatheter heart valves. METHODS: A multicenter prospective study was conducted, enrolling high-risk surgical patients with severe mitral annular calcification and symptomatic severe mitral valve dysfunction at 13 U.S. sites. RESULTS: Between February 2015 and December 2017, 31 patients were enrolled (median age 74.5 years [interquartile range (IQR): 71.3 to 81.0 years], 71% women, median Society of Thoracic Surgeons score 6.3% [IQR: 5.0% to 8.8%], 87.1% in New York Heart Association functional class III or IV). Access was transatrial (48.4%), transseptal (48.4%), or transapical (3.2%). Technical success was 74.2%. Left ventricular outflow tract obstruction (LVOTO) with hemodynamic compromise occurred in 3 patients (transatrial, n = 1; transseptal, n = 1; transapical, n = 1). After LVOTO occurred in the first 2 patients, pre-emptive alcohol septal ablation was implemented to decrease risk in high-risk patients. No intraprocedural deaths or conversions to open heart surgery occurred during the index procedures. All-cause mortality at 30 days was 16.7% (transatrial, 21.4%; transseptal, 6.7%; transapical, 100% [n = 1]; p = 0.33) and at 1 year was 34.5% (transatrial, 38.5%; transseptal, 26.7%; p = 0.69). At 1-year follow-up, 83.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.1 mm Hg (IQR: 5.6 to 7.1 mm Hg), and all patients had ≤1+ mitral regurgitation. CONCLUSIONS: At 1 year, ViMAC was associated with symptom improvement and stable transcatheter heart valve performance. Pre-emptive alcohol septal ablation may prevent transcatheter mitral valve replacement-induced LVOTO in patients at risk. Thirty-day mortality of patients treated via transseptal access was lower than predicted by the Society of Thoracic Surgeons score. Further studies are needed to evaluate safety and efficacy of ViMAC

    Transcatheter or surgical aortic-valve replacement in intermediate-risk patients

    Get PDF
    BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aorticvalve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan–Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoralaccess cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313
    • …
    corecore