6 research outputs found

    Tuning of Static and Dynamic Mechanical Response of Laser Powder Bed Fused AlSi10Mg Lattice Structures through Heat Treatments

    Get PDF
    The use of additive manufacturing allows the production of complex designs, including metallic lattice structures, which combine lightness and good mechanical properties. Herein, the production of AlSi10Mg lattice structures by laser powder bed fusion is explored and consistent processing parameters are selected. Thereafter, it is demonstrated that heat treatments, specifically designed on the basis of the alloy's metallurgy, can be used to selectively induce different microstructural modifications and, consequently, finely tune the static and dynamic mechanical behavior of the aluminum lattice structures. In particular, removal of residual stresses results to be the dominant factor in allowing a smooth quasistatic compressive behavior and improving the structure's ability to absorb energy during collapse. On the contrary, the increase in ductility connected to the spheroidization of the Si network is shown to be of paramount importance in improving the structure's dynamic damping ability by allowing local plasticization

    In Vitro Assessment of the Neuro-Compatibility of Fe-20Mn as a Potential Bioresorbable Material for Craniofacial Surgery

    Get PDF
    Background and Objectives:Spring-assisted surgery is a popular option for the treatment of non-syndromic craniosynostosis. The main drawback of this procedure is the need for a second surgery for spring removal, which could be avoided if a distractor material could be metabolised over time. Iron–Manganese alloys (FeMn) have a good trade-off between degradation rate and strength; however, their biocompatibility is still debated. Materials and Methods: In this study, the neuro-compatibility of Fe-20Mn (wt.%) was assessed using standard assays. PC-12 cells were exposed to Fe-20Mn (wt.%) and stainless steel via indirect contact. To examine the cytotoxicity, a Cell Tox Green assay was carried out after 1, 2, and 3 days of incubation. Following differentiation, a neurite morphological examination after 1 and 7 days of incubation time was carried out. The degradation response in modified Hank’s solution at 1, 3, and 7 days was investigated, too. Results: The cytotoxicity assay showed a higher toxicity of Fe-20Mn than stainless steel at earlier time points; however, at the latest time point, no differences were found. Neurite morphology was similar for cells exposed to Fe-20Mn and stainless steel.Conclusions: In conclusion, the Fe-20Mn alloy shows promising neuro-compatibility. Future studies will focus on in vivo studies to confirm the cellular response to Fe-20Mn.</p

    In Vitro Assessment of the Neuro-Compatibility of Fe-20Mn as a Potential Bioresorbable Material for Craniofacial Surgery

    Get PDF
    Background and Objectives: Spring-assisted surgery is a popular option for the treatment of non-syndromic craniosynostosis. The main drawback of this procedure is the need for a second surgery for spring removal, which could be avoided if a distractor material could be metabolised over time. Iron–Manganese alloys (FeMn) have a good trade-off between degradation rate and strength; however, their biocompatibility is still debated. Materials and Methods: In this study, the neuro-compatibility of Fe-20Mn (wt.%) was assessed using standard assays. PC-12 cells were exposed to Fe-20Mn (wt.%) and stainless steel via indirect contact. To examine the cytotoxicity, a Cell Tox Green assay was carried out after 1, 2, and 3 days of incubation. Following differentiation, a neurite morphological examination after 1 and 7 days of incubation time was carried out. The degradation response in modified Hank’s solution at 1, 3, and 7 days was investigated, too. Results: The cytotoxicity assay showed a higher toxicity of Fe-20Mn than stainless steel at earlier time points; however, at the latest time point, no differences were found. Neurite morphology was similar for cells exposed to Fe-20Mn and stainless steel. Conclusions: In conclusion, the Fe-20Mn alloy shows promising neuro-compatibility. Future studies will focus on in vivo studies to confirm the cellular response to Fe-20Mn

    Sensors and Actuation Technologies in Exoskeletons: A Review

    Get PDF
    Exoskeletons are robots that closely interact with humans and that are increasingly used for different purposes, such as rehabilitation, assistance in the activities of daily living (ADLs), performance augmentation or as haptic devices. In the last few decades, the research activity on these robots has grown exponentially, and sensors and actuation technologies are two fundamental research themes for their development. In this review, an in-depth study of the works related to exoskeletons and specifically to these two main aspects is carried out. A preliminary phase investigates the temporal distribution of scientific publications to capture the interest in studying and developing novel ideas, methods or solutions for exoskeleton design, actuation and sensors. The distribution of the works is also analyzed with respect to the device purpose, body part to which the device is dedicated, operation mode and design methods. Subsequently, actuation and sensing solutions for the exoskeletons described by the studies in literature are analyzed in detail, highlighting the main trends in their development and spread. The results are presented with a schematic approach, and cross analyses among taxonomies are also proposed to emphasize emerging peculiarities

    Retrospective Characterization of the 2006–2007 Swine Vesicular Disease Epidemic in Northern Italy by Whole Genome Sequence Analysis

    No full text
    Advances in the epidemiological tracing of pathogen transmission have been largely driven by the increasing characterisation of whole-genome sequence data obtained at a finer resolution from infectious disease outbreaks. Dynamic models that integrate genomic and epidemiological data further enhance inference on the evolutionary history and transmission dynamics of epidemic outbreaks by reconstructing the network of ‘who-infected-whom’. Swine Vesicular Disease (SVD) was present in Italy from 1966 until 2015, and since the mid-1990s, it has mainly been circulating within Italy’s central-southern regions with sporadic incursions to the north of the country. However, a recrudescence of SVD in northern Italy was recorded between November 2006 and October 2007, leading to a large-scale epidemic that significantly affected the intensive pig industry of the Lombardy region. In this study, by using whole-genome sequence data in combination with epidemiological information on disease occurrences, we report a retrospective epidemiological investigation of the 2006–2007 SVD epidemic, providing new insights into the transmission dynamics and evolutionary mode of the two phases that characterised the epidemic event. Our analyses support evidence of undetected premises likely missed in the chain of observed infections, of which the role as the link between the two phases is reinforced by the tempo of SVD virus evolution. These silent transmissions, likely resulting from the gradual loss of a clear SVD clinical manifestation linked to sub-clinical infections, may pose a risk of failure in the early detection of new cases. This study emphasises the power of joint inference schemes based on genomic and epidemiological data integration to inform the transmission dynamics of disease epidemics, ultimately aimed at better disease control

    Large-scale quantification of human osteocyte lacunar morphological biomarkers as assessed by ultra-high-resolution desktop micro-computed tomography

    No full text
    Ultra-high-resolution imaging of the osteocyte lacuno-canalicular network (LCN) three-dimensionally (3D) in a high-throughput fashion has greatly improved the morphological knowledge about the constituent structures – positioning them as potential biomarkers. Technologies such as serial focused ion beam/scanning electron microscopy (FIB/SEM) and confocal scanning laser microscopy (CLSM) can image in extremely high resolution, yet only capture a small number of lacunae. Synchrotron radiation computed tomography (SR-CT) can image with both high resolution and high throughput but has a limited availability. Desktop micro-computed tomography (micro-CT) provides an attractive balance: high-throughput imaging on the micron level without the restrictions of SR-CT availability. In this study, accuracy, reproducibility, and sensitivity of large-scale quantification of human osteocyte lacunar morphometries were assessed by ultra-high-resolution desktop micro-computed tomography. For this purpose, thirty-one transiliac human bone biopsies containing trabecular and cortical regions were imaged using ultra-high-resolution desktop micro-CT at a nominal isotropic voxel resolution of 1.2 µm. The resulting 3D images were segmented, component labeled, and the following morphometric parameters of 7.71 million lacunae were measured: Lacunar number (Lc.N), density (Lc.N/BV), porosity (Lc.TV/BV), volume (Lc.V), surface area (Lc.S), surface area to volume ratio (Lc.S/Lc.V), stretch (Lc.St), oblateness (Lc.Ob), sphericity (Lc.Sr), equancy (Lc.Eq), and angle (Lc.θ). Accuracy was quantified by comparing automated lacunar identification to manual identification. Mean true positive rate (TPR), false positive rate (FPR), and false negative rate (FNR) were 89.0%, 3.4%, and 11.0%, respectively. Regarding the reproducibility of lacunar morphometry from repeated measurements, precision errors were low (0.2–3.0%) and intraclass correlation coefficients were high (0.960–0.999). Significant differences between cortical and trabecular regions (p), and local lacunar volume (), all of which demonstrate the sensitivity of the method and are possible biomarker candidates. This study provides the foundation required for future large-scale morphometric studies using ultra-high-resolution desktop micro-CT and high-throughput analysis of millions of osteocyte lacunae in human bone samples.ISSN:8756-328
    corecore