333 research outputs found

    Summary of community technology needs

    Get PDF
    Applications of the social sciences and engineering to solution of the problem of airport noise are summarized. Specific needs are outlined

    Community noise

    Get PDF
    Airport and community land use planning as they relate to airport noise reduction are discussed. Legislation, community relations, and the physiological effect of airport noise are considered. Noise at the Logan, Los Angeles, and Minneapolis/St. Paul airports is discussed

    Strategic planning for aircraft noise route impact analysis: A three dimensional approach

    Get PDF
    The strategic routing of aircraft through navigable and controlled airspace to minimize adverse noise impact over sensitive areas is critical in the proper management and planning of the U.S. based airport system. A major objective of this phase of research is to identify, inventory, characterize, and analyze the various environmental, land planning, and regulatory data bases, along with potential three dimensional software and hardware systems that can be potentially applied for an impact assessment of any existing or planned air route. There are eight data bases that have to be assembled and developed in order to develop three dimensional aircraft route impact methodology. These data bases which cover geographical information systems, sound metrics, land use, airspace operational control measures, federal regulations and advisories, census data, and environmental attributes have been examined and aggregated. A three dimensional format is necessary for planning, analyzing space and possible noise impact, and formulating potential resolutions. The need to develop this three dimensional approach is essential due to the finite capacity of airspace for managing and planning a route system, including airport facilities. It appears that these data bases can be integrated effectively into a strategic aircraft noise routing system which should be developed as soon as possible, as part of a proactive plan applied to our FAA controlled navigable airspace for the United States

    Tantalum versus Titanium Acetabular Shells in Young Active THR Patients: A Radiostereometric Analysis (RSA) Study

    Get PDF
    Introduction: In the active THR (total hip replacement) population, acetabular component stability is crucial for preventing implant failure. Titanium fiber metal coating is the most common material used in cementless THR. Trabecular metal, composed of porous tantalum, is designed to improve tissue infiltration and limit migration. It is unknown if tantalum offers an advantage over titanium in the biologic fixation of porous-coated acetabular shells. Radiostereometric analysis (RSA) provides highly precise measurements of micromotion that are otherwise not detectable by routine radiographs. Methods: In this IRB approved, prospective, randomized, blinded study, 46 patients received a primary THR by a single surgeon. Each patient was randomized to receive a titanium (23) or tantalum (23) uncemented cup. Tantalum RSA markers were implanted around the polyethylene liner and into the patient’s femur and periacetabular bone. Also, patients received either a highly cross-linked (n=25) or a conventional liner (n=21). RSA examinations, Harris Hip, UCLA, WOMAC, SF-12 scores were obtained at 10 days, 6 months, and annually through 5 years. Results: The randomized groups had comparable mean age, preoperative activity, and average BMI. The tantalum shells demonstrated less median translation than the titanium shells at each time-point, but there was no statistical difference between the two shells. At 6 months median translation of tantalum and titanium was -0.01mm and 0.04mm and remained stable with median translation of -0.02mm and 0.04mm at four years. Mean UCLA, WOMAC, Harris Hip, and SF-12 PCS and MCS scores improved similarly in both groups. Conclusions: After THR, both patient cohorts had excellent clinical outcomes with statistically significant improvements in function and pain relief. Although tantalum porous-coated acetabular shells demonstrated less y-translation and y-rotation at all time points, there was no statistically significant difference in shell migration and both shells demonstrated excellent stability with minimal micromotion at four years

    Adrenergic Dysregulation and Pain With and Without Acute Beta-Blockade in Women With Fibromyalgia and Temporomandibular Disorder

    Get PDF
    In patients with fibromyalgia syndrome (FMS) and temporomandibular disorder (TMD), stress and pain may chronically enhance sympathetic activity, altering cardiovascular responses and worsening pain. This study examined cardiovascular, epinephrine (EPI), norepinephrine (NE), cortisol and clinical pain responses in 54 female patients with these disorders and 34 controls. In a subsample of 10 FMS, 10 TMD patients and 16 controls, using a counterbalanced, double-blind, cross-over design, the same responses were assessed after intravenous administration of low dose propranolol vs. placebo. Testing included baseline, postural, speech and ischemic pain stressors. FMS patients showed lesser heart rate (HR) increases to posture challenge but greater blood pressure (BP) increases to postural and speech tasks than Controls, as well as higher overall BP and greater total vascular resistance (TVR) than TMDs or Controls. TMDs showed higher overall cardiac output and lower TVR than Controls. Both FMS and TMD groups showed lower baseline NE than Controls, and TMDs showed lower overall EPI and NE levels. Group differences in HR, EPI and NE were abolished after propranolol although BP, CO and TVR differences persisted. In both FMS and TMD, number of painful body sites and ratings of total clinical pain obtained 4 times during each session were significantly lower after beta-blockade vs. placebo

    Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: A pilot Roentgen stereophotogrammetric analysis in 10 patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are presently few methods described for in vivo monitoring of the mechanics of healing human tendon ruptures, and no methods for prediction of clinical outcome. We tested if Roentgen stereophotogrammetric analysis (RSA) can be used to follow the restoration of mechanical properties during healing of ruptured Achilles tendons, and if early measurements can predict clinical results.</p> <p>Methods</p> <p>Achilles tendon repair was studied with RSA in 10 patients with a total rupture. Tantalum beads were implanted in conjunction with surgical repair. The patients were evaluated at 6, 12 and 18 weeks, and after 1 year. RSA was performed with two different mechanical loadings, and the strain induced by increasing load was measured. The transverse area was determined by ultrasound. CT scan at 12 weeks confirmed that the tantalum beads were located within the tendons. Functional testing was done after 1 year. A heel raise index was chosen as primary clinical outcome variable.</p> <p>Results</p> <p>The strain was median 0.90, 0.32 and 0.14 percent per 100 N tendon force at 6 weeks, 18 weeks and one year respectively. The error of measurement was 0.04 percent units at 18 weeks. There was a large variation between patients, which appears to reflect biological variation. From 6 to 18 weeks, there was a negative correlation between increase in transverse area and increase in material properties, suggesting that healing is regulated at the organ level, to maximize stiffness. Modulus of elasticity during this time correlated with a heel raise index at one year (Rho = 0.76; p = 0.02).</p> <p>Conclusion</p> <p>We conclude that the RSA method might have potential for comparing different treatments of Achilles tendon ruptures.</p

    Polyethylene Oxidation in Total Hip Arthroplasty: Evolution and New Advances

    Get PDF
    Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs

    A Mi\u27kmaq First Nation cosmology: investigating the practice of contemporary Aboriginal Traditional Medicine in dialogue with counselling – toward an Indigenous therapeutics

    Get PDF
    This paper explores from a Mi’kmaq and Aboriginal standpoint foundational knowledge in Indigenous therapeutics. Based on an eco-social-psycho-spiritual way of working, the article proposes Indigenous cultural models that open a window to a rich cultural repository of meanings associated with Indigenous cosmology, ontology and epistemology. The three layers of meaning, theory and practice within the symbolic ‘Medicine Lodge’ or ‘Place of The Dreaming’ give rise to ways of working that are deeply integrative and wholistic. These forms of Indigenous theory and practice have much to offer the counselling and complimentary health professions

    Assessment of bone ingrowth potential of biomimetic hydroxyapatite and brushite coated porous E-beam structures

    Get PDF
    The bone ingrowth potential of biomimetic hydroxyapatite and brushite coatings applied on porous E-beam structure was examined in goats and compared to a similar uncoated porous structure and a conventional titanium plasma spray coating. Specimens were implanted in the iliac crest of goats for a period of 3 (4 goats) or 15 weeks (8 goats). Mechanical implant fixation generated by bone ingrowth was analyzed by a push out test. Histomorphometry was performed to assess the bone ingrowth depth and bone implant contact. The uncoated and hydroxyapatite-coated cubic structure had significantly higher mechanical strength at the interface compared to the Ti plasma spray coating at 15 weeks of implantation. Bone ingrowth depth was significantly larger for the hydroxyapatite- and brushite-coated structures compared to the uncoated structure. In conclusion, the porous E-beam surface structure showed higher bone ingrowth potential compared to a conventional implant surface after 15 weeks of implantation. Addition of a calcium phosphate coating to the E-beam structure enhanced bone ingrowth significantly. Furthermore, the calcium phosphate coating appears to work as an accelerator for bone ingrowth

    Local Application of BMP-2 Specific Plasmids in Fibrin Glue does not Promote Implant Fixation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>BMP-2 is known to accelerate fracture healing and might also enhance osseointegration and implant fixation. Application of recombinant BMP-2 has a time-limited effect. Therefore, a gene transfer approach with a steady production of BMP-2 appears to be attractive. The aim of this study was to examine the effect of locally applied BMP-2 plasmids on the bone-implant integration in a non-weight bearing rabbit tibia model using a comparatively new non-viral copolymer-protected gene vector (COPROG).</p> <p>Methods</p> <p>Sixty rabbits were divided into 4 groups. All of them received nailing of both tibiae. The verum group had the nails inserted with the COPROG vector and BMP-2 plasmids using fibrin glue as a carrier. Controls were a group with fibrin glue only and a blank group. After 28 and 56 days, these three groups were sacrificed and one tibia was randomly chosen for biomechanical testing, while the other tibia underwent histomorphometrical examination. In a fourth group, a reporter-gene was incorporated in the fibrin glue instead of the BMP-2 formula to prove that transfection was successful.</p> <p>Results</p> <p>Implant fixation strength was significantly lower after 28 and 56 days in the verum group. Histomorphometry supported the findings after 28 days, showing less bone-implant contact.</p> <p>In the fourth group, successful transfection could be confirmed by detection of the reporter-gene in 20 of 22 tibiae. But, also systemic reporter-gene expression was found in heterotopic locations, showing an undesired spreading of the locally applied gene formula.</p> <p>Conclusion</p> <p>Our results underline the transfecting capability of this vector and support the idea that BMP-2 might diminish osseointegration. Further studies are necessary to specify the exact mechanisms and the systemic effects.</p
    corecore