843 research outputs found

    Stable Branched Electron Flow

    Full text link
    The pattern of branched electron flow revealed by scanning gate microscopy shows the distribution of ballistic electron trajectories. The details of the pattern are determined by the correlated potential of remote dopants with an amplitude far below the Fermi energy. We find that the pattern persists even if the electron density is significantly reduced such that the change in Fermi energy exceeds the background potential amplitude. The branch pattern is robust against changes in charge carrier density, but not against changes in the background potential caused by additional illumination of the sample.Comment: Accepted for publication in New Journal of Physic

    Detecting Determinacy in Prolog Programs: 22nd International Conference, ICLP 2006, Seattle, WA, USA, August 17-20, 2006. Proceedings

    Get PDF
    In program development it is useful to know that a call to a Prolog program will not inadvertently leave a choice-point on the stack. Determinacy inference has been proposed for solving this problem yet the analysis was found to be wanting in that it could not infer determinacy conditions for programs that contained cuts or applied certain tests to select a clause. This paper shows how to remedy these serious deficiencies. It also addresses the problem of identifying those predicates which can be rewritten in a more deterministic fashion. To this end, a radically new form of determinacy inference is introduced, which is founded on ideas in ccp, that is capable of reasoning about the way bindings imposed by a rightmost goal can make a leftmost goal deterministic

    A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell

    Full text link
    A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper reports on energy, time and spatial resolution capabilities of the first LXe prototype module equipped with a Position Sensitive Photo- Multiplier tube (PSPMT) operating in the VUV range (178 nm) and at 165 K. The experimental results show that such a LXe PET configuration might be a promising solution insensitive to any parallax effect.Comment: 34 pages, 18 pages, to appear in NIM

    The effect of physical therapy treatment in patients with subjective tinnitus:A systematic review

    Get PDF
    Background: Tinnitus is a very common symptom that often causes distress and decreases the patient's quality of life. Apart from the well-known causes, tinnitus can in some cases be elicited by dysfunctions of the cervical spine or the temporomandibular joint (TMJ). To date however, it is unclear whether alleviation of these dysfunctions, by physical therapy treatment, also decreases the tinnitus complaints. Such physical therapy could be an interesting treatment option for patients that are now often left without treatment. Objectives: The aim of this review was to investigate the current evidence regarding physical therapy treatment in patients with tinnitus. Data sources: The online databases Pubmed, Web of Science, Cochrane, and Embase were searched up to March 2016. Two independent reviewers conducted the data extraction and methodological quality assessment. Study eligibility criteria: Only randomized controlled trials and quasi-experimental trials were included in the review. Studies had to be written in English, French, Dutch, or German. Participants and interventions: The included studies investigated the effect of physical therapy treatment modalities on tinnitus severity in patients suffering from subjective tinnitus. Results: Six studies were included in this review, four investigating cervical spine treatment and two investigating TMJ treatment. These studies show positive effects of cervical spine treatment (manipulations, exercises, triggerpoint treatment) on tinnitus severity. Additionally, decrease in tinnitus severity and intensity was demonstrated after TMJ treatment, following splints, occlusal adjustments as well as jaw exercises. Limitations: The risk of bias in the included studies was high, mainly due to lack of randomization, lack of blinding of subjects, therapists, and/or investigators. Additionally, risk of bias is present due to incomplete presentation of the data and selective reporting. A major issue of the reviewed papers is the heterogeneity of the included study populations, treatments and outcome measures, which inhibit data pooling and meta-analysis. Conclusions: Despite the methodological issues in the included studies and the consequent low quality evidence, it is noteworthy that all included studies show positive treatment effects. Before recommendations can be made, these results need to be confirmed in larger, high quality studies, using unambiguous inclusion criteria, state-of-the-art treatment, and high quality outcome measures

    Hadron beam test of a scintillating fibre tracker system for elastic scattering and luminosity measurement in ATLAS

    Full text link
    A scintillating fibre tracker is proposed to measure elastic proton scattering at very small angles in the ATLAS experiment at CERN. The tracker will be located in so-called Roman Pot units at a distance of 240 m on each side of the ATLAS interaction point. An initial validation of the design choices was achieved in a beam test at DESY in a relatively low energy electron beam and using slow off-the-shelf electronics. Here we report on the results from a second beam test experiment carried out at CERN, where new detector prototypes were tested in a high energy hadron beam, using the first version of the custom designed front-end electronics. The results show an adequate tracking performance under conditions which are similar to the situation at the LHC. In addition, the alignment method using so-called overlap detectors was studied and shown to have the expected precision.Comment: 12 pages, 8 figures. Submitted to Journal of Instrumentation (JINST

    Absorption of Scintillation Light in a 100 â„“\ell Liquid XenonÎł\gamma Ray Detector and Expected Detector Performance

    Full text link
    An 800L liquid xenon scintillation γ\gamma ray detector is being developed for the MEG experiment which will search for μ+→e+γ\mu^+\to\mathrm{e}^+\gamma decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm3^3 to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and α\alpha sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.Comment: 18 pages, 10 figures (eps). Submitted to Nucl. Instr. and Meth.

    High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    Get PDF
    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM)

    Local host response following an intramammary challenge with Staphylococcus fleurettii and different strains of Staphylococcus chromogenes in dairy heifers

    Get PDF
    Coagulase-negative staphylococci (CNS) are a common cause of subclinical mastitis in dairy cattle. The CNS inhabit various ecological habitats, ranging between the environment and the host. In order to obtain a better insight into the host response, an experimental infection was carried out in eight healthy heifers in mid-lactation with three different CNS strains: a Staphylococcus fleurettii strain originating from sawdust bedding, an intramammary Staphylococcus chromogenes strain originating from a persistent intramammary infection (S. chromogenes IM) and a S. chromogenes strain isolated from a heifer's teat apex (S. chromogenes TA). Each heifer was inoculated in the mammary gland with 1.0 x 10(6) colony forming units of each bacterial strain (one strain per udder quarter), whereas the remaining quarter was infused with phosphate-buffered saline. Overall, the CNS evoked a mild local host response. The somatic cell count increased in all S. fleurettii-inoculated quarters, although the strain was eliminated within 12 h. The two S. chromogenes strains were shed in larger numbers for a longer period. Bacterial and somatic cell counts, as well as neutrophil responses, were higher after inoculation with S. chromogenes IM than with S. chromogenes TA. In conclusion, these results suggest that S. chromogenes might be better adapted to the mammary gland than S. fleurettii. Furthermore, not all S. chromogenes strains induce the same local host response
    • …
    corecore