14 research outputs found

    Good Reasons and Natural Ends: Rosalind Hursthouse's Hermeneutical Naturalism

    Get PDF
    My aims are exegetical rather than critical: I offer a systematic account of Hursthouse's ethical naturalism with an emphasis on the normative authority of the four ends, and try to correct some misconceptions found in the literature. Specifically, I argue that the four ends function akin to Wittgensteinian hinge-propositions for our practice of ethical reasoning and as such form part of a description of the logical grammar of said practice

    Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration

    Full text link
    BACKGROUND: Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES: To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor feedback. METHODS: Five healthy subjects and 12 patients with lung disease were monitored by portable RIP with sensors incorporated within a body garment. Unrestrained individuals were studied during 40-60 min while supine, sitting and upright/walking. Position was changed repeatedly every 5-10 min. Initial qualitative diagnostic calibration followed by volume scaling in absolute units during 20 breaths in different positions by flow meter provided position-specific volume-motion coefficients for RIP. These were applied during subsequent monitoring in corresponding positions according to feedback from 4 accelerometers placed at the chest and thigh. Accuracy of RIP was evaluated by face mask pneumotachography. RESULTS: Position sensor feedback allowed accurate adjustment of RIP calibration during repeated position changes in subjects and patients as reflected in a minor mean difference (bias) in breath-by-breath tidal volumes estimated by RIP and flow meter of 0.02 liters (not significant) and limits of agreement (+/-2 SD) of +/-19% (2,917 comparisons). An average of 10 breaths improved precision of RIP (limits of agreement +/-14%). CONCLUSIONS: RIP calibration incorporating position sensor feedback greatly enhances the application of RIP as a valuable, unobtrusive tool to investigate respiratory physiology and ventilatory limitation in unrestrained healthy subjects and patients with lung disease during everyday activities including position change

    Elevated γ-glutamyltransferase in implantable cardioverter defibrillator patients

    Full text link
    BACKGROUND: Elevated γ-glutamyltransferase (GGT) is a new risk factor for cardiovascular diseases, but its impact on ventricular tachyarrhythmia occurrence and survival in patients with an implantable cardioverter defibrillator (ICD) is unknown. METHODS AND RESULTS: Considering that GGT levels are gender-dependent, female ICD recipients were excluded from our database because of the low incidence of events. In a retrospective analysis, appropriate ICD therapy (both shocks and antitachycardia pacing due to ventricular tachyarrhythmias) occurred in 31.9% of 320 male patients who had received an ICD for primary prevention (median follow-up of 2.3 years), and in 55.1% of 423 male patients who had received an ICD for secondary prevention (median follow-up of 3.9 years). Compared to normal low GGT plasma levels (below 28 U/L), total mortality but not risk for appropriate ICD therapy was elevated for higher GGT categories (p for trend = 0.004 in primary prevention and p for trend = 0.002 in secondary prevention, respectively). In Cox regression analysis, elevated GGT (>56 U/L) remained an independent predictor of death both in primary (p = 0.011) and in secondary prevention (p = 0.006). Patients with elevated GGT and renal insufficiency defined by an estimated glomerular filtration rate <60 ml/min/1.73 m(2) suffered from excess total mortality jeopardizing the benefit of ICD therapy. CONCLUSION: Elevation of GGT is an important adverse prognostic parameter in ICD patients. A possible role of GGT for improved patient selection for ICD therapy deserves further investigation

    Time-varying signal analysis to detect high-altitude periodic breathing in climbers ascending to extreme altitude

    Get PDF
    This work investigates the performance of cardiorespiratory analysis detecting periodic breathing (PB) in chest wall recordings in mountaineers climbing to extreme altitude. The breathing patterns of 34 mountaineers were monitored unobtrusively by inductance plethysmography, ECG and pulse oximetry using a portable recorder during climbs at altitudes between 4497 and 7546 m on Mt. Muztagh Ata. The minute ventilation (VE) and heart rate (HR) signals were studied, to identify visually scored PB, applying time-varying spectral, coherence and entropy analysis. In 411 climbing periods, 30–120 min in duration, high values of mean power (MPVE) and slope (MSlopeVE) of the modulation frequency band of VE, accurately identified PB, with an area under the ROC curve of 88 and 89 %, respectively. Prolonged stay at altitude was associated with an increase in PB. During PB episodes, higher peak power of ventilatory (MPVE) and cardiac (MP LF HR ) oscillations and cardiorespiratory coherence (MP LF Coher ), but reduced ventilation entropy (SampEnVE), was observed. Therefore, the characterization of cardiorespiratory dynamics by the analysis of VE and HR signals accurately identifies PB and effects of altitude acclimatization, providing promising tools for investigating physiologic effects of environmental exposures and diseases
    corecore