474 research outputs found

    UK survey of occupational therapist’s and physiotherapist’s experiences and attitudes towards hip replacement precautions and equipment

    Get PDF
    Background: Total hip replacement (THR) is one of the most common orthopaedic procedures in the United Kingdom (UK). Historically, people following THR have been provided with hip precautions and equipment such as: raised toilet seats and furniture rises, in order to reduce the risks of dislocation post-operation. The purpose of this study was to determine current practices in the provision of these interventions in the UK for people following primary THR. Methods: A 27-question, self-administered online survey was developed and distributed to UK physiotherapists and occupational therapists involved in the management of people following primary THR (target respondents). The survey included questions regarding the current practices in the provision of equipment and hip precautions for THR patients, and physiotherapist’s and occupational therapist’s attitudes towards these practices. The survey was disseminated through print and web-based/social media channels. Results: 170 health professionals (87 physiotherapists and 83 occupational therapists), responded to the survey. Commonly prescribed equipment in respondent’s health trusts were raised toilet seats (95%), toilet frames and rails (88%), furniture raises (79%), helping hands/grabbers (77%), perching stools (75%) and long-handled shoe horns (75%). Hip precautions were routinely prescribed by 97% of respondents. Hip precautions were most frequently taught in a pre-operative group (52% of respondents). Similarly equipment was most frequently provided pre-operatively (61% respondents), and most commonly by occupational therapists (74% respondents). There was variability in the advice provided on the duration of hip precautions and equipment from up to six weeks post-operatively to life-time usage. Conclusions: Current practice on hip precautions and provision of equipment is not full representative of clinician’s perceptions of best care after THR. Future research is warranted to determine whether and to whom hip precautions and equipment should be prescribed post-THR as opposed to the current ‘blanket’ provision of equipment and movement restriction provided in UK practice

    The role of mentorship in protege performance

    Full text link
    The role of mentorship on protege performance is a matter of importance to academic, business, and governmental organizations. While the benefits of mentorship for proteges, mentors and their organizations are apparent, the extent to which proteges mimic their mentors' career choices and acquire their mentorship skills is unclear. Here, we investigate one aspect of mentor emulation by studying mentorship fecundity---the number of proteges a mentor trains---with data from the Mathematics Genealogy Project, which tracks the mentorship record of thousands of mathematicians over several centuries. We demonstrate that fecundity among academic mathematicians is correlated with other measures of academic success. We also find that the average fecundity of mentors remains stable over 60 years of recorded mentorship. We further uncover three significant correlations in mentorship fecundity. First, mentors with small mentorship fecundity train proteges that go on to have a 37% larger than expected mentorship fecundity. Second, in the first third of their career, mentors with large fecundity train proteges that go on to have a 29% larger than expected fecundity. Finally, in the last third of their career, mentors with large fecundity train proteges that go on to have a 31% smaller than expected fecundity.Comment: 23 pages double-spaced, 4 figure

    Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem.</p> <p>Methods</p> <p>Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined.</p> <p>Results</p> <p>On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively).</p> <p>Conclusion</p> <p>Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. Level of Evidence: Therapeutic Level III.</p

    Development and evaluation of a hand held computer based on-call pack for health protection out of hours duty: A pilot study

    Get PDF
    BACKGROUND: The on call service for health protection in most parts of the UK is provided by general public health consultants, registrars and nurses as the first tier of response backed up by medical consultants in health protection. The first tier responder usually carries a large bag of papers containing both local and national guidance on the management of common cases/incidents. An electronic on call pack may provide a suitable practical alternative to large paper based systems and help professionals deliver out of hours health protection advice and response to incidents. METHODS: We developed and piloted an electronic on call pack in Hertfordshire for use at the health protection unit level containing key local and national guidelines, contact information and useful references. The on-call pack was initially piloted using a laptop and more recently using a personal digital assistant (PDA). The use of the on-call pack was evaluated. RESULTS: Key advantages of the electronic system include reduced size, faster access to information that is clearly indexed and the relative ease of updating information. As part of the pilot, the electronic on call pack was presented to a local and regional training meeting with good response from participants using qualitative and quantitative methods. CONCLUSION: It is anticipated that with suitable evaluation this system can be adapted and utilised by other health protection practitioners. This system provides a fast, reliable and easily maintained source of information for the public health on-call team

    Word add-in for ontology recognition: semantic enrichment of scientific literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the current era of scientific research, efficient communication of information is paramount. As such, the nature of scholarly and scientific communication is changing; cyberinfrastructure is now absolutely necessary and new media are allowing information and knowledge to be more interactive and immediate. One approach to making knowledge more accessible is the addition of machine-readable semantic data to scholarly articles.</p> <p>Results</p> <p>The Word add-in presented here will assist authors in this effort by automatically recognizing and highlighting words or phrases that are likely information-rich, allowing authors to associate semantic data with those words or phrases, and to embed that data in the document as XML. The add-in and source code are publicly available at <url>http://www.codeplex.com/UCSDBioLit</url>.</p> <p>Conclusions</p> <p>The Word add-in for ontology term recognition makes it possible for an author to add semantic data to a document as it is being written and it encodes these data using XML tags that are effectively a standard in life sciences literature. Allowing authors to mark-up their own work will help increase the amount and quality of machine-readable literature metadata.</p
    corecore