81 research outputs found

    Statistical evaluation of tablet coating processes: influence of pan design and solvent type

    Get PDF
    Partially and fully perforated pan coaters are among the most relevant types of equipment currently used in the process of coating tablets. The goal of this study was to assess the performance differences among these types of equipment employing a factorial design. This statistical approach allowed the simultaneous study of the process variables and verification of interactions among them. The study included partially-perforated and fully-perforated pan coaters, aqueous and organic solvents, as well as hypromellose-based immediate-release coating. The dependent variables were process time, energy consumption, mean weight of tablets and process yield. For the tests, placebo tablets with a mean weight of 250 mg were produced, divided into eight lots of two kilograms each and coated in duplicate, using both partially perforated pan and fully perforated pan coaters. The results showed a significant difference between the type of equipment used (partially and fully perforated pan coaters) with regard to process time and energy consumption, whereas no significant difference was identified for mean weight of the coated tablets and process yield.Entre os tipos de equipamentos de maior relevância utilizados atualmente no processo de revestimento de comprimidos estão os de tambor parcial e totalmente perfurados. A proposta desse trabalho foi avaliar as diferenças de desempenho entre esses equipamentos empregando projeto fatorial. Essa abordagem estatística possibilitou o estudo simultâneo das variáveis do processo, permitindo verificar interações entre elas. O trabalho incluiu equipamento com tambor parcialmente perfurado e totalmente perfurado, solventes aquoso e orgânico, assim como revestimento de liberação imediata à base de hipromelose. As variáveis dependentes ou respostas foram tempo de processo, consumo de energia, peso médio e rendimento do processo. Para os ensaios, foram produzidos comprimidos de placebo de 250 mg de peso médio, divididos em 8 lotes de dois quilogramas cada e revestidos em duplicata, tanto no equipamento com tambor parcialmente perfurado quanto no equipamento de tambor totalmente perfurado, obedecendo a matriz de ensaio previamente definida. Os resultados mostraram que existe diferença significativa entre equipamento de tambor parcialmente perfurado e totalmente perfurado, para tempo de processo e consumo de energia. Já para peso médio dos comprimidos revestidos e rendimento do processo, os dois equipamentos não apresentaram diferença significativa

    Statistical evaluation of tablet coating processes: influence of pan design and solvent type

    Get PDF
    Partially and fully perforated pan coaters are among the most relevant types of equipment currently used in the process of coating tablets. The goal of this study was to assess the performance differences among these types of equipment employing a factorial design. This statistical approach allowed the simultaneous study of the process variables and verification of interactions among them. The study included partially-perforated and fully-perforated pan coaters, aqueous and organic solvents, as well as hypromellose-based immediate-release coating. The dependent variables were process time, energy consumption, mean weight of tablets and process yield. For the tests, placebo tablets with a mean weight of 250 mg were produced, divided into eight lots of two kilograms each and coated in duplicate, using both partially perforated pan and fully perforated pan coaters. The results showed a significant difference between the type of equipment used (partially and fully perforated pan coaters) with regard to process time and energy consumption, whereas no significant difference was identified for mean weight of the coated tablets and process yield.Entre os tipos de equipamentos de maior relevância utilizados atualmente no processo de revestimento de comprimidos estão os de tambor parcial e totalmente perfurados. A proposta desse trabalho foi avaliar as diferenças de desempenho entre esses equipamentos empregando projeto fatorial. Essa abordagem estatística possibilitou o estudo simultâneo das variáveis do processo, permitindo verificar interações entre elas. O trabalho incluiu equipamento com tambor parcialmente perfurado e totalmente perfurado, solventes aquoso e orgânico, assim como revestimento de liberação imediata à base de hipromelose. As variáveis dependentes ou respostas foram tempo de processo, consumo de energia, peso médio e rendimento do processo. Para os ensaios, foram produzidos comprimidos de placebo de 250 mg de peso médio, divididos em 8 lotes de dois quilogramas cada e revestidos em duplicata, tanto no equipamento com tambor parcialmente perfurado quanto no equipamento de tambor totalmente perfurado, obedecendo a matriz de ensaio previamente definida. Os resultados mostraram que existe diferença significativa entre equipamento de tambor parcialmente perfurado e totalmente perfurado, para tempo de processo e consumo de energia. Já para peso médio dos comprimidos revestidos e rendimento do processo, os dois equipamentos não apresentaram diferença significativa

    Validation of method to evaluate sanitary quality of lipophilic base cosmetics

    Get PDF
    A validação de método para a avaliação da qualidade sanitária de produto cosmético de base lipófila foi efetuada empregando-se neutralizantes químicos e diluição para a eliminação de efeito inibitório no crescimento microbiano. Para a preparação da amostra foi empregado miristato de isopropila e polissorbato 20. Além dessas substâncias, foi adicionado ao diluente 0,5% (p/v) de lecitina de soja visando à neutralização do cloreto de benzalcônio. Os ensaios foram efetuados objetivando a comprovação da ausência de efeito inibitório no crescimento microbiano decorrente de atividade antimicrobiana do produto, assim como dos agentes neutralizantes, tensoativos e solubilizante empregados no ensaio. Na avaliação quantitativa, os resultados demonstraram ausência de efeito inibitório no crescimento microbiano nas diluições 1:10 e 1:100. A porcentagem de microrganismos recuperados foi de, no mínimo, 93,2% indicando a validade do método de acordo com o critério oficial adotado. Com referência ao ensaio qualitativo, foi observado efeito inibitório na diluição 1:20 para os seguintes microrganismos: Pseudomonas aeruginosaeStaphylococcus aureus.Esse efeito foi eliminado empregando-se diluição 1:200, sendo, desta forma, essa diluição considerada válida para o ensaio.The validation of method to evaluate the sanitary quality of lipophilic base cosmetics was performed using chemical neutralizers and dilution in order to eliminate the inhibitory effect on the microbial growth. The preparation of the sample was performed aiming the homogeneity in the culture media. Isopropyl miristate was used for the solubilization of the sample and polysorbate 20 was used as surfactant. Besides these substances, it was added to the diluent 0.5% (w/v) of soy lecithin to neutralize the antimicrobial activity of the benzalkonium chloride. The purpose of the assays was to demonstrate the lack of inhibitory effect on the microbial growth due to antimicrobial activity of the product as well as of the neutralizing and solubilizing agents and the surfactant used in the assay. With regard to a quantitative evaluation, the results showed a lack of inhibitory effect of the product on the microbial growth in dilutions 1:10 and 1:100. The percentage of microbial recovery was at least 93.2% indicating the validation of the method in accordance with the official criteria adopted. As for the qualitative analysis, in dilution 1:20, it was noticed an inhibitory effect for the following microorganisms: Pseudomonas aeruginosa and Staphylococcus aureus.Since this mentioned effect was not noticed when dilution was 1:200, the latter dilution was considered valid for the assay

    Atividade antimicrobiana de quatro formulações diferentes de géis dentais em bactérias cariogênicas avaliada pelo método de regressão linear

    Get PDF
    The antimicrobial activity of four different dental gel formulas was evaluated on three microorganisms associated with cariogenesis: Streptococcus mutans, Lactobacillus casei and Actinomyces viscosus. The preliminary antimicrobial activity evaluation was performed using an agar diffusion method. In addition, the formulas were challenged using each microorganism with subsequent determinations of survivors at time intervals of 1, 5, 10, 20 and 30 minutes. The decimal reduction time (D-value) calculated from the obtained curves (logCFU/mL vs. time) was employed for the antimicrobial activity comparison of the formulas. The selected method for survivor enumeration was validated according to official compendia. Results revealed intense bactericidal activity, even at 1:2 dilution, on S. mutans and L. casei. The data concerning A. viscosus showed the absence of microbial reduction in the challenge employing diluted formulas at the selected time interval. The obtained D-values were 0.21, 2.08, 1.93 and 5.79 minutes for formulas 1, 2, 3 and 4, respectively. After comparing the obtained results, formula 1 can be considered to have the highest bactericidal activity.A atividade antimicrobiana de quatro diferentes fórmulas de gel dental foi avaliada empregando três microrganismos associados à cariogênese: Streptococcus mutans, Lactobacillus casei e Actinomyces viscosus. A avaliação preliminar foi efetuada utilizando método por difusão em ágar. Além disso, as fórmulas foram desafiadas empregando cada microrganismo e as determinações relativas aos sobreviventes foram efetuadas após 1, 5, 10, 20 e 30 minutos do desafio. O tempo de redução decimal (valor-D) foi calculado por meio das curvas obtidas (UFC/mL x tempo), objetivando a comparação da atividade antimicrobiana entre as fórmulas. O método selecionado para a enumeração dos sobreviventes foi validado de acordo com compêndio oficial. Os resultados revelaram intensa atividade antimicrobiana, inclusive na avaliação empregando diluição 1:2 dos produtos para os microrganismos Streptococcus mutans e Lactobacillus casei. Os dados relativos ao Actinomyces viscosus indicaram ausência de redução da população microbiana no desafio empregando produto diluído (1:2). Os valores-D obtidos foram 0,21, 2,08, 1,93 e 5,79 minutos para as fórmulas 1, 2, 3 e 4 respectivamente. Após comparação dos resultados obtidos, a fórmula 1 pode ser considerada aquela que apresentou maior atividade antimicrobiana

    Chitosan nanogels for biomedical applications: choosing a suitable sterilization method

    Get PDF
    Poster presented at the 10th World Biomaterials Congress. Montreal, Canada, 17-22 May 2016N/

    Co-delivery of buparvaquone and polymyxin B in a nanostructured lipid carrier for leishmaniasis treatment

    Get PDF
    Objectives: This study aimed to describe the preparation and in vitro evaluation of a surface-modified nanostructured lipid carrier (NLC) using chitosan and dextran for co-delivery of buparvaquone (BPQ) and polymyxin B (PB) against leishmaniasis. Methods: The NLC was prepared using high-pressure homogenisation. Polymyxin B binding and surface modification with biopolymers were achieved by electrostatic interaction. In vitro cytotoxicity was assessed in mouse peritoneal macrophages, and leishmanicidal activity in amastigotes of Leishmania infantum. Results: The performance attributes of BPQ-NLC, BPQ-NLC-PB[A −] (anionic) and BPQ-NLC-PB[C +] (cationic) were respectively: Z-average 173.9 ± 1.6, 183.8 ± 4.5 and 208.8 ± 2.6 nm; zeta potential −19.6 ± 1.5, −20.1 ± 1.1 and 31.1 ± 0.8 mV; CC 50 583.4 ± 0.10, 203.1 ± 0.04 and 5.7 ± 0.06 μM; IC 50 229.0 ± 0.04, 145.7 ± 0.04 and 150.5 ± 0.02 nM. The NLC in vitro leishmanicidal activity showed up to 3.1-fold increase when compared with free BPQ (P &lt; 0.05, α = 0.05). Conclusions: The developed NLC proved to be a promising formulation with which to overcome the drawbacks of current leishmaniasis treatment by the co-delivery of two alternative drugs and a macrophage targeting modified surface. </p

    Critical evaluation of the off-label indication and of the risks associated to the use of multi-dose vials on the treatment of age-related macular degeneration

    Get PDF
    Age-related macular degeneration (AMD) is an ocular inflammatory diseases treated mainly by means of a bevacizumab (Avastin®) or ranibizumab (Lucentis®) intravitreal injection. Among these drugs, only ranibizumab has a specific therapeutic indication for AMD. Considering that, the off-label use on ophthalmic therapy seems to become a rule when it should be an exception. Furthermore, bevacizumab presentation consists of multi-dose vials although it does not contain preservatives in its formula. The current literature review aimed at assessing the risks for the patient related to the use of off-label indication and multi-dose vials on AMD treatment. Considering this, the proposal related to the Brazilian Public Consultation no.10, dated September 12, 2012, which proposes the Clinical Protocol and Therapeutic Guidelines for AMD treatment, was evaluated. This systematic review allowed to conclude that the bevacizumab off-label indication results in increased risks for the patient when compared to the product with specific therapeutic indication for AMD treatment (ranibizumab), especially referring to the significant raise in the adverse events. The risks for the patient related to the multi-dose vial use, referring to the microbiological stability and dose precision, were also made clear.A degeneração macular relacionada à idade (DMRI) é uma doença ocular inflamatória tratada principalmente por injeção intravítrea de bevacizumabe (Avastin®) ou de ranibizumabe (Lucentis®). Entre os medicamentos citados, apenas o ranibizumabe tem indicação terapêutica específica para uso oftálmico. Considerando essa realidade, o uso off-label na terapia oftálmica parece constituir regra quando deveria ser exceção. Ademais, a apresentação do bevacizumabe consiste em frascos de múltipla-dose, embora esse medicamento não contenha conservante em sua fórmula. A presente revisão da literatura avaliou os riscos ao paciente relativos ao uso indicado off-label e de frascos de múltipla-dose no tratamento de DMRI. Nesse sentido, avaliou-se a proposta relativa à Consulta Pública Brasileira nº 10, de 12 de setembro de 2012, que propõe o Protocolo Clínico e Diretrizes Terapêuticas para o tratamento de DMRI. O levantamento sistemático de trabalhos científicos e de informações relevantes de banco de dados eletrônicos permitiu concluir que a indicação off-label do bevacizumabe acarreta riscos maiores ao paciente, quando comparado ao produto com indicação terapêutica específica para o tratamento de DMRI (ranibizumabe), especialmente quanto ao aumento significativo de eventos adversos. Evidenciaram-se, também, os riscos ao paciente relativos ao uso de frascos de múltipla-dose, quanto à estabilidade microbiológica e à precisão da dose

    Reverse phase high-performance liquid chromatography for quantification of hydroxymethylnitrofurazone in polymeric nanoparticles

    Get PDF
    Hidroximetilnitrofural (NFOH) é um novo composto que possui atividade leishmanicida e tripanomicida potencial. Um método apropriado foi desenvolvido e validado para a determinação de NFOH em nanopartículas de poli(n-butil cianoacrilato) (PBCA). A separação cromatográfica foi obtida usando uma coluna C18 (5 µm de tamanho de partícula, 4,6 mm de diâmetro e 150 mm de comprimento), mantida a 25 °C, fase móvel composta de água e acetonitrila 80:20 (v/v), fluxo de 1,2 mL min- 1 e detecção por UV a 265 nm. Investigaram-se os seguintes parâmetros de validação: seletividade, linearidade, exatidão, precisão e robustez (mudanças na temperatura de coluna, proporção da fase móvel e fluxo). O método mostrou-se específico, o pico de NFOH não apresentou interferência dos picos provenientes dos excipientes das nanopartículas e separado do principal produto de degradação (nitrofural). A linearidade foi obtida na faixa de 0,94-13,11 μg mL- 1 (r2=0,999). O método mostrou exatidão (recuperação de 100,7%, DPR de 0,4 %) e precisão (intra-dia e inter-dia, 9,98-9,99 μg mL- 1 e DPR 0,3% a 0,5%, respectivamente). A robustez provou que o método pode resistir às mudanças propostas. Aplicação do método otimizado revelou eficiência de encapsulação de 64,4% (n=3). Portanto, o método foi desenvolvido e validado com sucesso para a determinação da eficiência de encapsulação de nanopartículas de NFOH-PBCA.Hydroxymethylnitrofurazone (NFOH) is a new compound with potential leishmanicidal and trypanocidal activity. Despite its effectiveness, the formulators have to overcome its poor aqueous solubility. Recently, polymeric nano-scale drug delivery systems have proposed for the treatment of neglected diseases. As several studies have confirmed the advantages of such formulations, and this approach provides new analytical challenges, including the need to detect trace amounts of the drug. A suitable method was developed and validated for NFOH determination bound to poly (n-butylcyanoacrylate) (PBCA) nanoparticles. The chromatographic separation was achieved using a C18 column maintained at 25 ºC and an isocratic mobile phase consisting of water and acetonitrile: 80:20 (v/v) at a flow rate of 1.2 mL min-1 and UV-detection at 265 nm. Investigated validation parameters included selectivity, linearity, accuracy, precision and robustness (changes in column temperature, mobile phase composition and flow). The method was specific, the peak of NFOH had no interference with any nanoparticle excipients and no co-elution with main degradation product (nitrofurazone). Linearity was over the range of 0.94 13.11 μg mL-1 (r2=0.999). The method was accurate and precise, recovery of 100.7%, RSD of 0.4%; intra-day and inter-day RSD range 9.98-9.99 μg mL-1 and 0.3% to 0.5%, respectively. Robustness confirmed that method could resist the applied changes. Application of the optimized method revealed an encapsulation efficiency of 64.4% (n=3). Therefore, the method was successfully developed and validated for the determination of the encapsulation efficiency of NFOH-PBCA nanoparticles
    • …
    corecore