10 research outputs found
Feasibility and repeatability of ultrasound-guided surface electroenterography to measure colonic slow wave motility in healthy adults
Surface electroenterography is a potential non-invasive alternative to current diagnostics of colonic motility disorders. However, electrode positioning in electroenterography is often based on general anatomy and may lack generalizability. Furthermore, the repeatability of electroenterography measurements is unknown. This study aimed to evaluate ultrasound-guided electrode positioning for electroenterography measurements and to determine the repeatability of those measurements. In ten healthy adults, two electroenterography procedures were performed, consisting of fasting, ultrasound-guided electrode localization and two 20-minute electroenterography recordings separated by a meal. The dominant frequency, the mean power density (magnitude of colonic motility) and the power percent difference (relative pre- to postprandial increase in magnitude) were determined. Repeatability was determined by Lin’s concordance correlation coefficient. The results demonstrated that the dominant frequency did not differ between pre- and postprandial recordings and was 3 cpm, characteristic of colonic motility. The mean power density increased between the pre- and postprandial measurements, with an average difference of over 200%. The repeatability of both the dominant frequency and power density was poor to moderate, whereas the correlation coefficient of the power percent difference was poor. Concluding, ultrasound-guided surface electroenterography seems able to measure the gastrocolic reflex, but the dissatisfactory repeatability necessitates optimization of the measurement protocol.</p
Augmented versus Virtual Reality Laparoscopic Simulation: What Is the Difference?: A Comparison of the ProMIS Augmented Reality Laparoscopic Simulator versus LapSim Virtual Reality Laparoscopic Simulator
BACKGROUND: Virtual reality (VR) is an emerging new modality for laparoscopic skills training; however, most simulators lack realistic haptic feedback. Augmented reality (AR) is a new laparoscopic simulation system offering a combination of physical objects and VR simulation. Laparoscopic instruments are used within an hybrid mannequin on tissue or objects while using video tracking. This study was designed to assess the difference in realism, haptic feedback, and didactic value between AR and VR laparoscopic simulation. METHODS: The ProMIS AR and LapSim VR simulators were used in this study. The participants performed a basic skills task and a suturing task on both simulators, after which they filled out a questionnaire about their demographics and their opinion of both simulators scored on a 5-point Likert scale. The participants were allotted to 3 groups depending on their experience: experts, intermediates and novices. Significant differences were calculated with the paired t-test. RESULTS: There was general consensus in all groups that the ProMIS AR laparoscopic simulator is more realistic than the LapSim VR laparoscopic simulator in both the basic skills task (mean 4.22 resp. 2.18, P <0.000) as well as the suturing task (mean 4.15 resp. 1.85, P <0.000). The ProMIS is regarded as having better haptic feedback (mean 3.92 resp. 1.92, P <0.000) and as being more useful for training surgical residents (mean 4.51 resp. 2.94, P <0.000). CONCLUSIONS: In comparison with the VR simulator, the AR laparoscopic simulator was regarded by all participants as a better simulator for laparoscopic skills training on all tested feature
Objective assessment for open surgical suturing training by finger tracking can discriminate novices from experts
ABSTRACTIt is difficult, time consuming and expensive to assess manual skills in open surgery. The aim of this study is to investigate the construct validity of a low-cost, easily accessible tracking technique for basic open suturing tasks. Medical master students, surgical residents, and surgeons at the Radboud University Medical Center were recruited between September 2020 until September 2021. The participants were divided, according to experience, in a novice group (≤10 sutures performed) and an expert group (>50 sutures performed). For objective tracking, a tablet with SurgTrac software was used, which tracked a blue and a red tag placed on respectively their left and right index finger. The participants executed four basic tasks on a suturing model: 1) knot tying by hand, 2) transcutaneous suturing with an instrument knot, 3) ‘Donati’ (vertical mattress suture) with an instrument knot and 4) continuous intracutaneous suturing without a knot. In total 76 participants were included: 57 novices and 19 experts. All four tasks showed significant differences between the novice group and expert group for the parameters time (p<0.001), distance (p<0.001 for Task 1, 2 and 3 and p=0.034 for Task 4) and smoothness (p<0.001). Additionally, Task 3 showed a significant difference for the parameter handedness (p=0.006) and Task 4 for speed (p=0.033). Tracking index finger movements using SurgTrac software on a tablet while executing basic open suturing skills on a simulator shows excellent construct validity for time, distance and motion smoothness in all four suturing tasks
A software-based tool for video motion tracking in the surgical skills assessment landscape
Background: The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine the possibility of using a software-based solution to extract the data. Methods: 6 expert and 23 novice participants performed a basic laparoscopic cholecystectomy procedure in the operating room. The recorded videos were analysed using Kinovea 0.8.15 and the following parameters calculated the path length, average instrument movement and number of sudden or extreme movements. Results: The analysed data showed that experts had significantly shorter path length (median 127 cm vs. 187 cm, p = 0.01), smaller average movements (median 0.40 cm vs. 0.32 cm, p = 0.002) and fewer sudden movements (median 14.00 vs. 21.61, p = 0.001) than their novice counterparts. Conclusion: The use of software-based video motion tracking of laparoscopic cholecystectomy is a simple and viable method enabling objective assessment of surgical performance. It provides clear discrimination between expert and novice performance.Applied Ergonomics and DesignIndustrial Desig
Competency assessment tool for laparoscopic suturing: Development and reliability evaluation
Background: Laparoscopic suturing can be technically challenging and requires extensive training to achieve competency. To date no specific and objective assessment method for laparoscopic suturing and knot tying is available that can guide training and monitor performance in these complex surgical skills. In this study we aimed to develop a laparoscopic suturing competency assessment tool (LS-CAT) and assess its inter-observer reliability. Methods: We developed a bespoke CAT tool for laparoscopic suturing through a structured, mixed methodology approach, overseen by a steering committee with experience in developing surgical assessment tools. A wide Delphi consultation with over twelve experts in laparoscopic surgery guided the development stages of the tool. Following, subjects with different levels of laparoscopic expertise were included to evaluate this tool, using a simulated laparoscopic suturing task which involved placing of two surgical knots. A research assistant video recorded and anonymised each performance. Two blinded expert surgeons assessed the anonymised videos using the developed LS-CAT. The LS-CAT scores of the two experts were compared to assess the inter-observer reliability. Lastly, we compared the subjects’ LS-CAT performance scores at the beginning and end of their learning curve. Results: This study evaluated a novel LS-CAT performance tool, comprising of four tasks. Thirty-six complete videos were analysed and evaluated with the LS-CAT, of which the scores demonstrated excellent inter-observer reliability. Cohen’s Kappa analysis revealed good to excellent levels of agreement for almost all tasks of both instrument handling and tissue handling (0.87; 0.77; 0.75; 0.86; 0.85, all with p < 0.001). Subjects performed significantly better at the end of their learning curve compared to their first attempt for all LS-CAT items (all with p < 0.001). Conclusions: We developed the LS-CAT, which is a laparoscopic suturing grading matrix, with excellent inter-rater reliability and to discriminate between experience levels. This LS-CAT has a potential for wider use to objectively assess laparoscopic suturing skills.</p
Validation of Motion Tracking Software for Evaluation of Surgical Performance in Laparoscopic Cholecystectomy
Motion tracking software for assessing laparoscopic surgical proficiency has been proven to be effective in differentiating between expert and novice performances. However, with several indices that can be generated from the software, there is no set threshold that can be used to benchmark performances. The aim of this study was to identify the best possible algorithm that can be used to benchmark expert, intermediate and novice performances for objective evaluation of psychomotor skills. 12 video recordings of various surgeons were collected in a blinded fashion. Data from our previous study of 6 experts and 23 novices was also included in the analysis to determine thresholds for performance. Video recording were analyzed both by the Kinovea 0.8.15 software and a blinded expert observer using the CAT form. Multiple algorithms were tested to accurately identify expert and novice performances. ½ L + 13 A + 16 J scoring of path length, average movement and jerk index respectively resulted in identifying 23/24 performances. Comparing the algorithm to CAT assessment yielded in a linear regression coefficient R2 of 0.844. The value of motion tracking software in providing objective clinical evaluation and retrospective analysis is evident. Given the prospective use of this tool the algorithm developed in this study proves to be effective in benchmarking performances for psychomotor skills evaluation.Applied Ergonomics and DesignMedical Instruments & Bio-Inspired TechnologyHuman-Centered Desig
Competency assessment tool for laparoscopic suturing: Development and reliability evaluation
Background: Laparoscopic suturing can be technically challenging and requires extensive training to achieve competency. To date no specific and objective assessment method for laparoscopic suturing and knot tying is available that can guide training and monitor performance in these complex surgical skills. In this study we aimed to develop a laparoscopic suturing competency assessment tool (LS-CAT) and assess its inter-observer reliability. Methods: We developed a bespoke CAT tool for laparoscopic suturing through a structured, mixed methodology approach, overseen by a steering committee with experience in developing surgical assessment tools. A wide Delphi consultation with over twelve experts in laparoscopic surgery guided the development stages of the tool. Following, subjects with different levels of laparoscopic expertise were included to evaluate this tool, using a simulated laparoscopic suturing task which involved placing of two surgical knots. A research assistant video recorded and anonymised each performance. Two blinded expert surgeons assessed the anonymised videos using the developed LS-CAT. The LS-CAT scores of the two experts were compared to assess the inter-observer reliability. Lastly, we compared the subjects’ LS-CAT performance scores at the beginning and end of their learning curve. Results: This study evaluated a novel LS-CAT performance tool, comprising of four tasks. Thirty-six complete videos were analysed and evaluated with the LS-CAT, of which the scores demonstrated excellent inter-observer reliability. Cohen’s Kappa analysis revealed good to excellent levels of agreement for almost all tasks of both instrument handling and tissue handling (0.87; 0.77; 0.75; 0.86; 0.85, all with p < 0.001). Subjects performed significantly better at the end of their learning curve compared to their first attempt for all LS-CAT items (all with p < 0.001). Conclusions: We developed the LS-CAT, which is a laparoscopic suturing grading matrix, with excellent inter-rater reliability and to discriminate between experience levels. This LS-CAT has a potential for wider use to objectively assess laparoscopic suturing skills.Applied Ergonomics and Desig
Virtual Operating Room Simulation Setup (VORSS) for Procedural Training in Minimally Invasive Surgery: a Pilot Study
Virtual reality (VR) training is widely used in several minimal invasive surgery (MIS) training curricula for procedural training. However, VR training in its current state lack immersive training environments, such as using head-mounted displays that is implemented in military or aviation training and even entertainment. The virtual operating room simulation setup (VORSS) is explored in this study to determine the effectiveness of immersive training in MIS. Twenty-eight surgeons and surgical trainees performed a laparoscopic cholecystectomy on the VORSS comprising of a head-mounted 360-degree realistic OR surrounding on a VR laparoscopic simulator. The VORSS replicated a full setup of instruments and surgical team-members as well as some of the distractions occurring during surgical procedures. Questionnaires were followed by semi-structured interviews to collect the data. Experts and novices found the VORSS to be intuitive and easy to use (p = 0.001). The outcome of the usability test, applying QUESI and NASA-TLX, reflected the usability of the VORSS (p < 0.05), at the cognitive level, which indicates a good sense of immersion and satisfaction, when performing the procedure within VORSS. The need for personalized experience within the setup was strongly noted from most of the participants. The VORSS for procedural training has the potential to become a useful tool to provide immersive training in MIS surgery. Further optimizing of the VORSS realism and introduction of distractors in the OR should result in an improvement of the system.Applied Ergonomics and DesignEducation and Research SupportHuman-Centered Desig
Paediatric appendicitis: International study of management in the COVID-19 pandemic
[No abstract available]Medicinska Forskningsrådet, MFRT.W. received a grant from the Swedish Medical Research Council. The Swedish Medical Research Council had no role in any part of the study