105 research outputs found

    Dendritic Cells in Human Atherosclerosis: From Circulation to Atherosclerotic Plaques

    Get PDF
    Background. Atherosclerosis is a chronic inflammatory disease with atherosclerotic plaques containing inflammatory infiltrates predominantly consisting of monocytes/macrophages and activated T cells. More recent is the implication of dendritic cells (DCs) in the disease. Since DCs were demonstrated in human arteries in 1995, numerous studies in humans suggest a role for these professional antigen-presenting cells in atherosclerosis. Aim. This paper focuses on the observations made in blood and arteries of patients with atherosclerosis. In principal, flow cytometric analyses show that circulating myeloid (m) and plasmacytoid (p) DCs are diminished in coronary artery disease, while immunohistochemical studies describe increased intimal DC counts with evolving plaque stages. Moreover, mDCs and pDCs appear to behave differently in atherosclerosis. Yet, the origin of plaque DCs and their relationship with blood DCs are unknown. Therefore, several explanations for the observed changes are postulated. In addition, the technical challenges and discrepancies in the research field are discussed. Future. Future studies in humans, in combination with experimental animal studies will unravel mechanisms leading to altered blood and plaque DCs in atherosclerosis. As DCs are crucial for inducing but also dampening immune responses, understanding their life cycle, trafficking and function in atherosclerosis will determine potential use of DCs in antiatherogenic therapies

    Cost-effectiveness of tailored print communication, telephone motivational interviewing, and a combination of the two: results of an economic evaluation alongside the Vitalum randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of the present study was to evaluate the cost-effectiveness of tailored print communication (TPC), telephone motivational interviewing (TMI), a combination of the two, and no intervention on two outcomes in adults aged 45 to 70, half of them having hypertension: increasing the number of public health guidelines met for three behaviors (physical activity and fruit and vegetable consumption), and impact on quality adjusted life years (QALYs).</p> <p>Methods</p> <p>Participants (<it>n </it>= 1,629) from 23 Dutch general practices were randomized into one of four groups, which received 4 TPCs, 4 TMIs, 2 of each (combined), or no intervention (control), respectively. The self-reported outcomes, measured at baseline and 73 weeks follow-up (7 months after the last intervention component), were difference in total number of guidelines met at follow-up compared to baseline, and number of QALYs experienced over 73 weeks. The costs of implementing the intervention were estimated using a bottom-up approach.</p> <p>Results</p> <p>At 73 weeks follow-up participants showed increased adherence with 0.62 (TPC), 0.40 (TMI), 0.50 (combined), and 0.26 (control) guidelines compared to baseline, and experienced 1.09, 1.08, 1.08, and 1.07 QALYs, respectively. The costs for the control group were considered to be zero. TMI was more expensive (€107 per person) than both the combined intervention (€80) and TPC (€57). The control condition was most cost-effective for lower ceiling ratios, while TPC had the highest probability of being most cost-effective for higher ceiling ratios (more than €160 per additional guideline met, and €2,851 for each individual QALY).</p> <p>Conclusions</p> <p>For low society's willingness to pay, the control group was most cost-effective for the number of QALYs experienced over 73 weeks. This also applied to the increase in the number of guidelines met at lower ceiling ratios, whereas at higher ceiling ratios, TPC had a higher probability of being more cost-effective than the TMI, combined or control conditions. This also seemed to apply for QALYs experienced over 73 weeks. More research is needed on the long-term efficacy of both TPC and TMI, as well as on how to increase their cost-effectiveness.</p> <p>Trial registration</p> <p>Dutch Trial Register NTR1068</p

    Final 3-year clinical outcomes following transcatheter aortic valve implantation with a supra-annular self-expanding repositionable valve in a real-world setting: Results from the multicenter FORWARD study.

    Get PDF
    OBJECTIVES The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study. BACKGROUND Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce. METHODS FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients. RESULTS Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low. CONCLUSIONS The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low

    Impact of tissue adhesives on the prevention of anastomotic leakage of colonic anastomoses: an in vivo study

    Get PDF
    Background: Tissue adhesives (TA) may be useful to strengthen colorectal anastomoses, thereby preventing anastomotic leakage (AL). Previous studies have identified cyanoacrylate (CA) TAs as the most promising colonic anastomotic sealants. This stud

    Uncertainties and challenges in surgical and transcatheter tricuspid valve therapy: a state-of-the-art expert review

    Get PDF
    Tricuspid regurgitation (TR) is a frequent and complex problem, commonly combined with left-sided heart disease, such as mitral regurgitation. Significant TR is associated with increased mortality if left untreated or recurrent after therapy. Tricuspid regurgitation was historically often disregarded and remained undertreated. Surgery is currently the only Class I Guideline recommended therapy for TR, in the form of annuloplasty, leaflet repair, or valve replacement. As growing experience of transcatheter therapy in structural heart disease, many dedicated transcatheter tricuspid repair or replacement devices, which mimic well-established surgical techniques, are currently under development. Nevertheless, many aspects of TR are little understood, including the disease process, surgical or interventional risk stratification, and predictors of successful therapy. The optimal treatment timing and the choice of proper surgical or interventional technique for significant TR remain to be elucidated. In this context, we aim to highlight the current evidence, underline major controversial issues in this field and present a future roadmap for TR therapy

    Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study

    Get PDF
    Aim Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre ‘real-world' patient population in highly experienced centres. Methods and results Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. Conclusion The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosi

    Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis: The International FORWARD Study

    Get PDF
    Background Clinical outcomes in large patient populations from real-world clinical practice with a next-generation self-expanding transcatheter aortic valve are lacking. Objectives This study sought to document the clinical and device performance outcomes of transcatheter aortic valve replacement (TAVR) with a next-generation, self-expanding transcatheter heart valve (THV) system in patients with severe symptomatic aortic stenosis (AS) in routine clinical practice. Methods The FORWARD (CoreValve Evolut R FORWARD) study is a prospective, single-arm, multinational, multicenter, observational study. An independent clinical events committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms. From January 2016 to December 2016, TAVR with the next-generation self-expanding THV was attempted in 1,038 patients with symptomatic, severe AS at 53 centers on 4 continents. Results Mean age was 81.8 ± 6.2 years, 64.9% were women, the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 5.5 ± 4.5%, and 33.9% of patients were deemed frail. The repositioning feature of the THV was applied in 25.8% of patients. A single valve was implanted in the proper anatomic location in 98.9% of patients. The mean aortic valve gradient was 8.5 ± 5.6 mm Hg, and moderate or severe aortic regurgitation was 1.9% at discharge. All-cause mortality was 1.9%, and disabling stroke occurred in 1.8% at 30 days. The expected-to-observed early surgical mortality ratio was 0.35. A pacemaker was implanted in 17.5% of patients. Conclusions TAVR using the next-generation THV is clinically safe and effective for treating older patients with severe AS at increased operative risk. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369
    corecore