431 research outputs found
Transcribed ultraconserved noncoding RNAs (T-UCR) are involved in Barrett's esophagus carcinogenesis.
Barretts esophagus (BE) involves a metaplastic replacement of native esophageal squamous epithelium (Sq) by columnar-intestinalized mucosa, and it is the main risk factor for Barrett-related adenocarcinoma (BAc). Ultra-conserved regions (UCRs) are a class non-coding sequences that are conserved in humans, mice and rats. More than 90% of UCRs are transcribed (T-UCRs) in normal tissues, and are altered at transcriptional level in tumorigenesis. To identify the T-UCR profiles that are dysregulated in Barretts mucosa transformation, microarray analysis was performed on a discovery set of 51 macro-dissected samples obtained from 14 long-segment BE patients. Results were validated in an independent series of esophageal biopsy/surgery specimens and in two murine models of Barretts esophagus (i.e. esophagogastric-duodenal anastomosis). Progression from normal to BE to adenocarcinoma was each associated with specific and mutually exclusive T-UCR signatures that included up-regulation of uc.58-, uc.202-, uc.207-, and uc.223- and down-regulation of uc.214+. A 9 T-UCR signature characterized BE versus Sq (with the down-regulation of uc.161-, uc.165-, and uc.327-, and the up-regulation of uc.153-, uc.158-, uc.206-, uc.274-, uc.472-, and uc.473-). Analogous BE-specific T-UCR profiles were shared by human and murine lesions. This study is the first demonstration of a role for T-UCRs in the transformation of Barretts mucosa
Accurate reference gas mixtures containing tritiated molecules: Their production and raman‐based analysis
Highly accurate, quantitative analyses of mixtures of hydrogen isotopologues—both the stable species, H, D2, and HD, and the radioactive species, T, HT, and DT—are of great importance in fields as diverse as deuterium–tritium fusion, neutrino mass measurements using tritium β-decay, or for photonuclear experiments in which hydrogen–deuterium targets are used. In this publication we describe a production, handling, and analysis facility capable of fabricating well-defined gas samples, which may contain any of the stable and radioactive hydrogen isotopologues, with sub-percent accuracy for the relative species concentrations. The production is based on precise manometric gas mixing of H, D, and T. The heteronuclear isotopologues HD, HT, and DT are generated via controlled, in-line catalytic reaction or by β-induced self-equilibration, respectively. The analysis was carried out using an in-line intensity- and wavelength-calibrated Raman spectroscopy system. This allows for continuous monitoring of the composition of the circulating gas during the self-equilibration or catalytic evolution phases. During all procedures, effects, such as exchange reactions with wall materials, were considered with care. Together with measurement statistics, these and other systematic effects were included in the determination of composition uncertainties of the generated reference gas samples. Measurement and calibration accuracy at the level of 1% was achieved
Monitoring of tritium purity during long-term circulation in the KATRIN test experiment LOOPINO using laser Raman spectroscopy
The gas circulation loop LOOPINO has been set up and commissioned at Tritium
Laboratory Karlsruhe (TLK) to perform Raman measurements of circulating tritium
mixtures under conditions similar to the inner loop system of the neutrino-mass
experiment KATRIN, which is currently under construction. A custom-made
interface is used to connect the tritium containing measurement cell, located
inside a glove box, with the Raman setup standing on the outside. A tritium
sample (purity > 95%, 20 kPa total pressure) was circulated in LOOPINO for more
than three weeks with a total throughput of 770 g of tritium. Compositional
changes in the sample and the formation of tritiated and deuterated methanes
CT_(4-n)X_n (X=H,D; n=0,1) were observed. Both effects are caused by hydrogen
isotope exchange reactions and gas-wall interactions, due to tritium {\beta}
decay. A precision of 0.1% was achieved for the monitoring of the T_2
Q_1-branch, which fulfills the requirements for the KATRIN experiment and
demonstrates the feasibility of high-precision Raman measurements with tritium
inside a glove box
Neutral tritium gas reduction in the KATRIN differential pumping sections
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the
effective electron anti-neutrino mass with an unprecedented sensitivity of
, using -electrons from tritium decay.
The electrons are guided magnetically by a system of superconducting magnets
through a vacuum beamline from the windowless gaseous tritium source through
differential and cryogenic pumping sections to a high resolution spectrometer
and a segmented silicon pin detector. At the same time tritium gas has to be
prevented from entering the spectrometer. Therefore, the pumping sections have
to reduce the tritium flow by more than 14 orders of magnitude. This paper
describes the measurement of the reduction factor of the differential pumping
section performed with high purity tritium gas during the first measurement
campaigns of the KATRIN experiment. The reduction factor results are compared
with previously performed simulations, as well as the stringent requirements of
the KATRIN experiment.Comment: 19 pages, 4 figures, submitted to Vacuu
Recommended from our members
Assessment of cleaning to control lead dust in homes of children with moderate lead poisoning: treatment of lead-exposed children trial
In this article we describe the assessment and control of lead dust exposure in the Treatment of Lead-exposed Children (TLC) Trial, a clinical trial of the effects of oral chelation on developmental end points in urban children with moderately elevated blood lead levels. To reduce potential lead exposure from settled dust or deteriorated paint during the drug treatment phase of the trial, the homes of 765 (98%) of the randomized children (both active and placebo drug treatment groups) were professionally cleaned. Lead dust measurements were made in a sample of 213 homes before and after cleaning. Geometric mean dust lead loadings before cleaning were 43, 29, 308, and 707 micro g/ft2 in the kitchen floor, playroom floor, playroom windowsill, and playroom window well samples respectively. Following cleaning, floor dust lead loadings were reduced on average 32% for paired floor samples (p < 0.0001), 66% for windowsills (p < 0.0001), and 93% for window wells (p < 0.0001). Cleaning was most effective for 146 homes with precleaning dust lead levels above the recommended clearance levels, with average reductions of 44%, 74%, and 93% for floors (p < 0.0001), windowsills (p < 0.0001), and window wells (p < 0.0001), respectively. Despite these substantial reductions in dust lead loadings, a single professional cleaning did not reduce the lead loadings of all dust samples to levels below current federal standards for lead in residential dust. Attainment of dust levels below current standards will require more intensive cleaning and lead hazard reduction strategies
The KATRIN Pre-Spectrometer at reduced Filter Energy
The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of
the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement
of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An
ultra-low background of about b = 10 mHz is among the requirements to reach
this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E
filter type are used in a tandem configuration. This setup, however, produces a
Penning trap which could lead to increased background. We have performed test
measurements showing that the filter energy of the pre-spectrometer can be
reduced by several keV in order to diminish this trap. These measurements were
analyzed with the help of a complex computer simulation, modeling multiple
electron reflections both from the detector and the photoelectric electron
source used in our test setup.Comment: 22 pages, 12 figure
A combined analysis of short-baseline neutrino experiments in the (3+1) and (3+2) sterile neutrino oscillation hypotheses
We investigate adding two sterile neutrinos to resolve the apparent tension
existing between short-baseline neutrino oscillation results and
CPT-conserving, four-neutrino oscillation models. For both (3+1) and (3+2)
models, the level of statistical compatibility between the combined dataset
from the null short-baseline experiments Bugey, CHOOZ, CCFR84, CDHS, KARMEN,
and NOMAD, on the one hand; and the LSND dataset, on the other, is computed. A
combined analysis of all seven short-baseline experiments, including LSND, is
also performed, to obtain the favored regions in neutrino mass and mixing
parameter space for both models. Finally, four statistical tests to compare the
(3+1) and the (3+2) hypotheses are discussed. All tests show that (3+2) models
fit the existing short-baseline data significantly better than (3+1) models.Comment: 16 pages, 15 figures. Added NOMAD data to the analysis, one
statistical test, and two figures. References and text added. Version
submitted to PR
- …