68 research outputs found

    Which stem in total hip arthroplasty for developmental hip dysplasia? A comparative study using a 3D CT-based software for pre-operative surgical planning

    Get PDF
    Background Stem choice in total hip arthroplasty (THA) for hip dysplasia is still controversial. The aims of the study were to evaluate (1) which stem design provided the highest percentage of adequate reconstructions in THA for dysplasia and (2) any correlation between the reconstructions provided by the stems and the native femoral morphology. Materials and methods 150 CT scans including 200 adult dysplastic hips were randomly selected. Using the 3D CT-based software Hip-Op for surgical planning, the native hip anatomy was studied. Then, a single wedge tapered stem, an anatomical stem and a conical tapered stem were simulated in every hip. An adequate reconstruction of hip biomechanics was obtained when combined anteversion, offset restoration, coronal and sagittal tilt, canal filling and leg lengthening were inside the normal ranges. Results Conical stems achieved the highest percentage of adequate reconstructions (87%, p < 0.0001). The anatomical stem was the worst performer. Single wedge and anatomical stem acceptability was mainly influenced by the combined anteversion. Stem anteversion was correlated with the femoral anteversion (fair correlation), the calcar femorale (fair) and the mediolateral femoral diameter at isthmus (poor). When the femoral anteversion was >= 25 degrees, combined anteversion was very acceptable for the conical stem (99.2%), whereas the rate of acceptable combined anteversion for the single wedge tapered stem was 71.4%, and that for the anatomical stem was 51.6% (p < 0.0001). Conclusions Stem choice in developmental hip dysplasia is mainly driven by appropriate combined anteversion, which is dependent on the coronal and axial femoral morphologies. As a rule of thumb, tapered stems are adequate when femoral anteversion is < 25 degrees; conical stems should be adopted for higher anteversions

    Relationship between obesity and early failure of total knee prostheses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Obesity is a risk factor for knee arthritis. Total knee arthroplasty is the definitive surgical treatment of this disease. Therefore, a high percentage of subjects treated are overweight. Since 2000 in the Emilia-Romagna Region the Register of Orthopedic Prosthetic Implantology, RIPO, has recorded data of all the primary and revision operations performed on the knee; height and weight of patients at the time of surgery have also been recorded.</p> <p>Methods</p> <p>To understand how overweight and obesity affect the outcome of knee arthroplasty, a population of subjects treated with cemented total knee arthroplasty between 2000 and 2005 was studied. 9735 knee prostheses were implanted in 8892 patients; 18.9% of the patients were normal weight, 48.2% were overweight (25 < Body Mass Index <= 30), 31.1% were obese (30 < BMI <= 40), and 1.8% were morbidly obese (BMI > 40). Mean and range of follow-up were respectively 3.1 and 1.5–6 yrs. Implant failure was defined as the exchange of at least one component for whatever reason.</p> <p>Results</p> <p>In normal weight patients there were 36 failures out of 1840 implants (1.96%), in overweight patients there were 87 out of 4692 (1.85%), in obese 59 out of 3031 (1.94%), and in morbidly obese there were 4 out of 172 (2.3%). The mean time to failure for each class was 1.57, 1.48, 1.60, 1.77 yrs. Cox regression analyses showed that the risk of implant failure was not influenced by BMI, absolute body weight, or sex. Conversely, an increased failure risk was observed in mobile meniscus prostheses in comparison with those with a fixed meniscus (Rate Ratio 1.88); an increased failure risk was also related to age (Rate Ratio 1.05 per year). These results were also confirmed when considering septic loosening as the end-point. There were no differences in the rate of perioperative complications and death in the 4 classes of BMI.</p> <p>Conclusion</p> <p>In conclusion, cemented knee prostheses, implanted in patients with arthritis do not have significantly different rates of survival or perioperative complications in obese subjects compared with normal weight subjects, at least up to 5 years after surgery. The conclusion also applies to subjects affected by morbid obesity, altough this findings should be regarded with caution due to the small sample examined.</p

    A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture

    Get PDF
    Background Ceramic bearings are used in total hip arthroplasty due to their excellent wear behaviour and biocompatibility. The major concern related to their use is material brittleness, which significantly impacts on the risk of fracture of ceramic components. Fracture toughness improvement has contributed to the decrease in fracture rate, at least of the prosthetic head. However, the root cause behind these rare events is not fully understood. This study evaluated head fracture occurrence in a sizeable cohort of patients with fourth-generation ceramic-on-ceramic implants and described the circumstances reported by patients in the rare cases of head fracture. Methods The clinical survivorship of 29,495 hip prostheses, with fourth-generation ceramic bearings, was determined using data from a joint replacement registry. The average follow-up period was 5.2 years (range 0.1-15.6). Retrieval analysis was performed in one case for which the ceramic components were available. Results Clinical outcomes confirmed the extremely low fracture rate of fourth-generation ceramic heads: only two out of 29,495 heads fractured. The two fractures, both involving 36 mm heads, occurred without a concurrent or previous remarkable trauma. Considering the feature of the fractured head, a multi-stage crack growth mechanism has been hypothesized to occur following damage at the head-neck taper interface. Conclusions Surgeons must continue to pay attention to the assembly of the femoral head: achieving a proper head seating on a clean taper is a prerequisite to decrease the risk of occurrence of any damage process within head-neck junction, which may cause high stress concentration at the contact surface, promoting crack nucleation and propagation even in toughened ceramics

    Preoperative and postoperative risk factors for periprosthetic joint infection in primary total hip arthroplasty: A 1-year experience

    Get PDF
    BACKGROUND Periprosthetic joint infection (PJI) in primary total hip replacement (THR) is one of the most important threats in orthopedic surgery, so one important surgeon's target is to avoid or early diagnose a PJI. Although the incidence of PJI is very low (0.69%) in our department, with an average follow-up of 595 d, this infection poses a serious threat due to the difficulties of treatment and the lower functional outcomes after healing. AIM To study the incidence of PJI in all operations occurring in the year 2016 in our department to look for predictive signs of potential infection. METHODS We counted 583 THR for 578 patients and observed only 4 cases of infection (0.69%) with a mean follow-up of 596 d (min 30, max 1451). We reviewed all medical records to collect the data: duration and time of the surgery, presence, type and duration of the antibiotic therapy, preoperative diagnosis, blood values before and after surgery, transfusions, presence of preoperative drugs (in particularly anticoagulants and antiaggregant, corticosteroids and immunosuppressants), presence of some comorbidities (high body mass index, blood hypertension, chronic obstructive pulmonary disease, cardiac ischemia, diabetes, rheumatological conditions, previous local infections). RESULTS No preoperative, intraoperative, or postoperative analysis showed a higher incidence of PJI. We did not find any class with evident major odds of PJI. In our study, we did not find any border value to predict PJI and all patients had similar values in both groups (non-PJI and PJI). Only some categories, such as female patients, showed more frequency of PJI, but this difference related to sex was not statistically significant. CONCLUSION We did not find any category with a higher risk of PJI in THR, probably due to the lack of few cases of infection

    Classification Scheme of Heating Risk during MRI Scans on Patients with Orthopaedic Prostheses

    Get PDF
    Due to the large variety of possible clinical scenarios, a reliable heating-risk assessment is not straightforward when patients with arthroplasty undergo MRI scans. This paper proposes a simple procedure to estimate the thermal effects induced in patients with hip, knee, or shoulder arthroplasty during MRI exams. The most representative clinical scenarios were identified by a preliminary frequency analysis, based on clinical service databases, collecting MRI exams of 11,658 implant carrier patients. The thermal effects produced by radiofrequency and switching gradient fields were investigated through 588 numerical simulations performed on an ASTM-like phantom, considering four prostheses, two static field values, seven MR sequences, and seven regions of imaging. The risk assessment was inspired by standards for radiofrequency fields and by scientific studies for gradient fields. Three risk tiers were defined for the radiofrequency, in terms of whole-body and local SAR averages, and for GC fields, in terms of temperature elevation. Only 50 out of 588 scenarios require some caution to be managed. Results showed that the whole-body SAR is not a self-reliant safety parameter for patients with metallic implants. The proposed numerical procedure can be easily extended to any other scenario, including the use of detailed anatomical models

    Patient-reported outcome measures (PROMs) after elective hip, knee and shoulder arthroplasty: protocol for a prospective cohort study

    Get PDF
    Background The number of hip, knee and shoulder arthroplasties continues to rise worldwide. The Organization for Economic Cooperation and Development has launched an initiative (called PaRIS Initiative) for the systematic collection of Patient Reported Outcome Measures (PROMs) in patients undergoing elective hip and knee arthroplasty. The Rizzoli Orthopedic Institute (IOR) was selected as a pilot center for the launch of the Initiative in Italy given that IOR hosts the Registry of Orthopedic Prosthetic Implants (RIPO), a region-wide registry which collects joint implant data from all the hospitals in the Emilia-Romagna Region. In this specific geographic area information related to PROMs after joint replacement is unknown. This paper describes the protocol of a study (PaRIS-IOR) that aims to implement the collection of a set of PROMs within an existing implant registry in Italy. The study will also investigate the temporal trend of PROMs in relation to the type of prosthesis and the type of surgical intervention. Methods The PaRIS-IOR study is a prospective, single site, cohort study that consists of the administration of PROMs questionnaires to patients on the list for elective arthroplasty. The questionnaires will be administered to the study population within 30 days before surgery, and then at 6 and 12 months following surgery. The study population will consist of consecutive adult patients undergoing either hip, knee or shoulder arthroplasty. The collected data will be linked with those routinely collected by the RIPO in order to assess the temporal trend of PROMs in relation to the type of prosthesis and the type of surgical intervention. Discussion The PaRIS-IOR study could have important implications in targeting the factors influencing functional outcomes and quality of life reported by patients after hip, knee and shoulder arthroplasty, and will also represent the first systematic collection of PROMs related to arthroplasty in Italy

    Modeling the Cost-Effectiveness for Cement-Less and Hybrid Prosthesis in Total Hip Replacement in Emilia Romagna, Italy

    Get PDF
    Background. The aim of the present study was to assess the cost-effectiveness of cement-less versus hybrid prostheses in total hip replacement (THR) in patients diagnosed with primary osteoarthritis. Methods. Effectiveness data were obtained from the Emilia-Romagna Regional Registry on Orthopaedic Prosthesis (RIPO), which collects information on all orthopaedic intervention performed in Emilia-Romagna (41,199 total hip replacements performed from 2000 to 2007), and from which we obtained survival curves and transition probabilities for the cement-less and hybrid prostheses, respectively. Conversely, costs were derived from regional databases through a specific procedure, which allowed us to register individual component's costs for both primary and subsequent revision interventions. A specific Markov transition model was constructed in order to consider the 3 types of revisions that an implant could possibly undergo through its life-span: total, cup or stem, head insert or neck. The cost-effectiveness was expressed in terms of cost per "revision-free" life year. Results and conclusions. Considering a 70-y old patient undergoing THR, the cementless strategy resulted more effective but more costly than the hybrid solution, with an incremental cost effectiveness ratio of 2401.63 (sic) per revision-free life year. Following a deterministic sensitivity analysis, hybrid and cementless fixation showed, respectively, a dominance profile for patients older than 83 y and younger than 43 y, whereas for all ages in between, we report a progressive increase in the ICER of cementless prostheses. Our results proved to be robust, as underlined by the probabilistic sensitivity analysis performed using cost distributions. (C) 2011 Elsevier Inc. All rights reserved

    Patient reported outcomes measures (PROMs) trajectories after elective hip arthroplasty: a latent class and growth mixture analysis

    Get PDF
    Patient-reported outcome measures (PROMs) are an extensively used tool to assess and improve the quality of healthcare services. PROMs can be related to individual demographic and clinical characteristics in patients undergoing hip arthroplasty (HA). The aim of this study is to identify distinct subgroups of patients with unique trajectories of PROMS scores and to determine patients' features associated with these subgroups

    Towards a muon collider

    Get PDF
    A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work
    • …
    corecore